• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Dual Power-Supply Supervisors
Dual Power-Supply Supervisors

... low, respectively) for a time delay (td) after system voltages have achieved normal levels. Above VCC = 3.5 V, taking RESIN low activates the time-delay function during normal system-voltage levels. To ensure that the microcomputer system has reset, the outputs remain active until the voltage at VSU ...
ADN4665 数据手册DataSheet 下载
ADN4665 数据手册DataSheet 下载

... whereas the operating current of voltage-mode drivers increases exponentially in most cases. This is caused by the overlap current as internal gates switch between high and low, which causes currents to flow from the device power supply to ground. A current-mode device simply reverses a constant cur ...
Low-Power Reference and Bipolar Input Voltage Conditioning Circuit
Low-Power Reference and Bipolar Input Voltage Conditioning Circuit

Single-Inductor Dual-Output Buck-Boost Power Factor
Single-Inductor Dual-Output Buck-Boost Power Factor

Chapter 24 Electrical Power
Chapter 24 Electrical Power

... system is provided by an alternator and/or the battery. The alternator serves as the main component to power the electrical system and charge the battery during normal conditions. The battery is used for starting the engine and powering the electrical system when alternator power is not available (e ...
D_LKAT2_revA
D_LKAT2_revA

... Displays bus current on a 3.5 digit digital display behind the clear meter unit front door. The option also includes an RMS converter to provide current display in AC measurement applications. NOTE: This option changes electronics maximum ambient temperature from 60ºC to 50ºC Specify Item 43639 ...
CH.3:Electrical Network Study 3.1: Element Of The Network A
CH.3:Electrical Network Study 3.1: Element Of The Network A

... It is a load flow program which can simulink the power system receiving the input data (source ,transformer ,T.L & loads) as One Line Diagram ...
the use of protective earth as a distributor of fields and radiation
the use of protective earth as a distributor of fields and radiation

User Manual for 16V/58F Modules
User Manual for 16V/58F Modules

... conditioned environments. In systems with voltages greater than 60V, protection of the terminals to avoid shock and corrosion should be instituted. Modules that are expected to see significant cycling should be mounted in free air or in a forced ventilation housing. Care should be taken to protect m ...
P84391
P84391

... respectively). These models allow for independent operation of the strobe circuit and the horn circuit. It is the ideal choice for retrofit applications as well as new installations. The HS4 appliance is UL Listed under Standard 1971 for Signaling Applicances for the Hearing Impaired and UL Standard ...
Failure Mechanisms For Transient Voltage Suppressors
Failure Mechanisms For Transient Voltage Suppressors

... becomes important since it is located in front of a sensitive load as a parallel shunt path to redirect any high voltage transient threats to ground before they damage the load it is intended to protect. NOTE: When a TVS is properly selected in voltage, it is transparent to the circuit or simply idl ...
10 Universal Signal Inputs CAN Controller
10 Universal Signal Inputs CAN Controller

Ranger Power Master 7000 (PM7000)
Ranger Power Master 7000 (PM7000)

... normally up to 2 cycles before the event and up to 5 cycles after. However, captures may be extended up to 60 seconds after the event with different extensions for individual triggers. ...
2014 RA420 PEMC2014 135-Ozsoy
2014 RA420 PEMC2014 135-Ozsoy

... Penetration of renewable energy sources, especially wind energy conversion systems has been increasing due to rapid ...
Interfacing an ADC
Interfacing an ADC

... 4. Referring to the BalloonSat manual, identify the circuit board pads for the analog-todigital converter inputs. The BalloonSat board has square pads for connecting a voltage source to the individual analog inputs of the 4-channel ADC0834 chip. These are labelled CH0, CH1, CH2 and CH3. You will con ...
TL97x Output Rail-To-Rail Very-Low-Noise
TL97x Output Rail-To-Rail Very-Low-Noise

... 9.1.2.1 Output Voltage Swing The output voltage of an operational amplifier is limited by its internal circuitry to some level below the supply rails. For this amplifier, the output voltage must be within ±12 V. 9.1.2.2 Supply and Input Voltage For correct operation of the amplifier, neither input m ...
3-V to 17-V 1-A Step-Down Converter with DCS
3-V to 17-V 1-A Step-Down Converter with DCS

... appropriate level or not. The PG signal can be used for startup sequencing of multiple rails. The PG pin is an open-drain output that requires a pull-up resistor (to any voltage below 7 V). It can sink 2 mA of current and maintain its specified logic low level. It is high impedance when the device i ...
TLV7256 - Texas Instruments
TLV7256 - Texas Instruments

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
ppt
ppt

... Fair weather electric field: The background electric field that exists in the lower atmosphere. The strength of the field is about 100 V/m In general the atmosphere is positively charged and the surface of the earth is negatively charged. ...
MC33340, MC33342 Battery Fast Charge
MC33340, MC33342 Battery Fast Charge

... capacity and operating time while preventing overcharging. Overcharging can result in a reduction of battery life as well as physical harm to the end user. Since most portable applications require the batteries to be charged rapidly, a primary and usually a secondary or redundant charge sensing tech ...
IEEE Transactions on Magnetics
IEEE Transactions on Magnetics

... efficiency. To improve the line current quality, the switching frequency of the grid-connected inverter is expected to increase. Higher switching frequency is also helpful for decreasing the size and the cost of the filter. However, higher switching frequency leads to higher switching loss [1]. The ...
display
display

... i. measure voltage at motor and be sure it tracks from 0 – 24 Volts with PWM percentage ii. Voltage must be within 0.5V of 24V multiplied by PWM percentage d. Attach steering motor to J4 e. vary PWM from 0 – 100% in forward direction, (10% increments) i. measure voltage at motor and be sure it trac ...
Short guide to working out cable sizes
Short guide to working out cable sizes

... installation work need to understand the procedure for selecting the correct cross-sectional area of a cable for a particular use. It is the intention of this article to explain simply how to select the correct cross-sectional area of cables with particular single-phase loads in mind. I’ll refer to ...
DWARF II - Trigon Audio
DWARF II - Trigon Audio

... gives - what music plays – with sensitivity and power to the speaker. It is the mediator between the music and its emotions. The DWARF II unites precise technology, high operational safety and operating comfort. A long distance signal way protected switch design supervises the amplifier electronic. ...
Valve Regulated Lead Acid Battery User`s Manual by Storage
Valve Regulated Lead Acid Battery User`s Manual by Storage

... An equalizing (refreshing) charge shall be carried out according to charging section 3.0 after this time or if the average open cell voltage drops below 2.10 volts per cell. Alternatively cells can be float charged during storage. ...
< 1 ... 595 596 597 598 599 600 601 602 603 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report