quicktronic® controllable 14w t5 systems
... provides for full compatibility with occupancy sensors and building control systems. QUICKSENSE technology helps to protect against overheating bases and sockets, as well as cracking of the glass wall, as lamps reach the end of useful life. It also features dynamic lamp sensing to avoid false shutdo ...
... provides for full compatibility with occupancy sensors and building control systems. QUICKSENSE technology helps to protect against overheating bases and sockets, as well as cracking of the glass wall, as lamps reach the end of useful life. It also features dynamic lamp sensing to avoid false shutdo ...
MAX9010–MAX9013 SC70, 5ns, Low-Power, Single-Supply, Precision TTL Comparators General Description
... Note 4: Although Common-Mode Input Voltage Range is restricted to -0.2V ≤ VCM ≤ (VCC - 1.9V), either or both inputs can go to either absolute maximum voltage limit, i.e., from -0.3V to (VCC + 0.3V), without damage. The comparator will make a correct (and fast) logic decision provided that at least o ...
... Note 4: Although Common-Mode Input Voltage Range is restricted to -0.2V ≤ VCM ≤ (VCC - 1.9V), either or both inputs can go to either absolute maximum voltage limit, i.e., from -0.3V to (VCC + 0.3V), without damage. The comparator will make a correct (and fast) logic decision provided that at least o ...
GSD1 User Manual - Automation Direct
... and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for ...
... and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for ...
DS96172/DS96174 RS-485/RS-422 Quad
... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
The Split printers, as supplied, are powered by 24VCD supplied
... Compared with the DIN plug these are very straightforward to assemble. I used male plugs on the battery leads and female plugs on the DIN plug leads, though this is arbitrary. The positive wire red (or brown) was soldered to the centre pin and socket, again this is arbitrary. Before wiring up the in ...
... Compared with the DIN plug these are very straightforward to assemble. I used male plugs on the battery leads and female plugs on the DIN plug leads, though this is arbitrary. The positive wire red (or brown) was soldered to the centre pin and socket, again this is arbitrary. Before wiring up the in ...
Electrical circuit models for performance modeling of Lithium
... potential due to their high theoretical specific capacity (approx. 1675 Ah/kg) and theoretical energy density of almost 2600 Wh/kg. To analyze the suitability of this new emerging technology for various applications, there is a need for Li-S battery performance model; however, developing such models ...
... potential due to their high theoretical specific capacity (approx. 1675 Ah/kg) and theoretical energy density of almost 2600 Wh/kg. To analyze the suitability of this new emerging technology for various applications, there is a need for Li-S battery performance model; however, developing such models ...
why we need haptics in touch screens?
... ● Possible to use multiple piezo actuators to provide stronger / localized haptic feedback ● Can be also used as sensors to detect vibration or pressure ● Can provide fast and short (duration 2ms) feedback ● Suitable for touch sensations ● Vibrate range from 150hz to 300hz ...
... ● Possible to use multiple piezo actuators to provide stronger / localized haptic feedback ● Can be also used as sensors to detect vibration or pressure ● Can provide fast and short (duration 2ms) feedback ● Suitable for touch sensations ● Vibrate range from 150hz to 300hz ...
AD8628
... amplifiers. Using Analog Devices, Inc., topology, these zerodrift amplifiers combine low cost with high accuracy and low noise. No external capacitor is required. In addition, the AD8628/ AD8629/AD8630 greatly reduce the digital switching noise found in most chopper-stabilized amplifiers. With an of ...
... amplifiers. Using Analog Devices, Inc., topology, these zerodrift amplifiers combine low cost with high accuracy and low noise. No external capacitor is required. In addition, the AD8628/ AD8629/AD8630 greatly reduce the digital switching noise found in most chopper-stabilized amplifiers. With an of ...
Product Group: Vishay Foil Resistors
... Of the four parameters listed above, in-situ accurate measurement of current output was found to be the most important parameter by far in reducing noise. All 60 channels of the existing HPC equipment were upgraded to allow for more reliable measurement of current through the use of Bulk Metal Z-Foi ...
... Of the four parameters listed above, in-situ accurate measurement of current output was found to be the most important parameter by far in reducing noise. All 60 channels of the existing HPC equipment were upgraded to allow for more reliable measurement of current through the use of Bulk Metal Z-Foi ...
ASCO Model 420 Guide Specifications (word version)
... of all fuses must be indicated on the status panel. Unit Status Indicators—SPD shall have an integral status circuit that monitors the operational status of all modes of protection, including Line to Neutral, Line to Ground and Neutral to Ground. No manual testing is required to confirm the integrit ...
... of all fuses must be indicated on the status panel. Unit Status Indicators—SPD shall have an integral status circuit that monitors the operational status of all modes of protection, including Line to Neutral, Line to Ground and Neutral to Ground. No manual testing is required to confirm the integrit ...
POWER ANALYZER 3390
... ■ Application 1: “Electrical angle measurement” ○ The voltage / current fundamental wave component “θ” from the machine angle origin can be calculated by performing harmonic analysis of motor input voltage / current by synchronizing to the A-phase signal and z-phase signal of an encoder. ○ A functio ...
... ■ Application 1: “Electrical angle measurement” ○ The voltage / current fundamental wave component “θ” from the machine angle origin can be calculated by performing harmonic analysis of motor input voltage / current by synchronizing to the A-phase signal and z-phase signal of an encoder. ○ A functio ...
(GFCI) with Self Test and Lockout
... and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor th ...
... and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor th ...
MAX44244/MAX44245/MAX44248 36V, Precision, Low-Power, 90µA, Single/Quad/Dual Op Amps General Description
... operation with a wide supply range. The devices incorporate a patented auto-zero circuit that constantly measures and compensates the input offset to eliminate drift over time and temperature as well as the effect of 1/f noise. These devices also feature integrated EMI filters to reduce high-frequen ...
... operation with a wide supply range. The devices incorporate a patented auto-zero circuit that constantly measures and compensates the input offset to eliminate drift over time and temperature as well as the effect of 1/f noise. These devices also feature integrated EMI filters to reduce high-frequen ...
Open-Loop Torque Boost and Simple Slip Frequency Compensation
... constant V/f control induction motor drive is proposed. This proposed scheme fully compensates for the stator resistance voltage drop by vectorially modifying the stator voltage and keeping the magnitude of the stator flux constant. The simple slip frequency compensation, based on an estimation of t ...
... constant V/f control induction motor drive is proposed. This proposed scheme fully compensates for the stator resistance voltage drop by vectorially modifying the stator voltage and keeping the magnitude of the stator flux constant. The simple slip frequency compensation, based on an estimation of t ...
Galvanically Isolated Modular Converter - Infoscience
... output, the SST efficiency is further reduced due to the LV inverter output stage that has to deal with large currents [14]. An SST concept similar to the dual-active-bridge, but based on an MMC, has been proposed in [15] or with an improved modulation concept in [16]. The use of high-voltage wide ba ...
... output, the SST efficiency is further reduced due to the LV inverter output stage that has to deal with large currents [14]. An SST concept similar to the dual-active-bridge, but based on an MMC, has been proposed in [15] or with an improved modulation concept in [16]. The use of high-voltage wide ba ...
SIGC39T60E
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
3011800000610
... the degradation of the output swing may be so high that the circuit does not oscillate. III. POST LAYOUT SIMULATION RESULTS In this design, we mainly aimed for a low phase-noise to meet the phase noise specification of the IEEE 802.11a standard. High and linear tuning range capability is another des ...
... the degradation of the output swing may be so high that the circuit does not oscillate. III. POST LAYOUT SIMULATION RESULTS In this design, we mainly aimed for a low phase-noise to meet the phase noise specification of the IEEE 802.11a standard. High and linear tuning range capability is another des ...
Up to 3 A step-down switching regulator
... The starter supplies the start-up current to the entire device when the input voltage goes high and the device is enabled (inhibit pin connected to ground). The pre-regulator block supplies the bandgap cell with a pre-regulated voltage that has a very low supply voltage noise sensitivity. ...
... The starter supplies the start-up current to the entire device when the input voltage goes high and the device is enabled (inhibit pin connected to ground). The pre-regulator block supplies the bandgap cell with a pre-regulated voltage that has a very low supply voltage noise sensitivity. ...
MAX4361/MAX4362/MAX4363 ADSL Drivers/Receivers for Customer Premise Equipment General Description
... with a fixed gain of 3.1V/V. The MAX4362 is a dual amplifier with shutdown intended for use as a differential IN/differential OUT driver with gain set with external resistors. The MAX4363 is a quad amplifier with shutdown intended for use as a differential IN/differential OUT driver/receiver combina ...
... with a fixed gain of 3.1V/V. The MAX4362 is a dual amplifier with shutdown intended for use as a differential IN/differential OUT driver with gain set with external resistors. The MAX4363 is a quad amplifier with shutdown intended for use as a differential IN/differential OUT driver/receiver combina ...
True RMS Autoranging Multimeter
... identifies them as being associated with ranges that may, in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test leads should not be handled when these terminals are energized. This symbol indicates that a device is protected throughout by double i ...
... identifies them as being associated with ranges that may, in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test leads should not be handled when these terminals are energized. This symbol indicates that a device is protected throughout by double i ...
Reduced Voltage Starters Type S
... Part winding starters can only be used with part winding motors which have two sets of identical windings, intended to be operated in parallel. During a part winding start, only one winding is energized, reducing the inrush current to 60-70% (depending on the motor design) and starting torque to 50% ...
... Part winding starters can only be used with part winding motors which have two sets of identical windings, intended to be operated in parallel. During a part winding start, only one winding is energized, reducing the inrush current to 60-70% (depending on the motor design) and starting torque to 50% ...
Zero-Sequence Harmonics Current Minimization Using Zero
... Fig.3.shows the system configuration of the Zig-Zag transformer applied in the three-phase four-wire distribution power systems. In Fig. 3, Z Ln is the impedance of neutral conductor between the load and the Zig-Zag transformer, Z Sn is the impedance of neutral conductor between the utility and the ...
... Fig.3.shows the system configuration of the Zig-Zag transformer applied in the three-phase four-wire distribution power systems. In Fig. 3, Z Ln is the impedance of neutral conductor between the load and the Zig-Zag transformer, Z Sn is the impedance of neutral conductor between the utility and the ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.