Agilent AN 372-1 Power Supply Testing
... measurements. However, certain instruments are essential to all tests, regardless of the implementation. Some commercially available turnkey power supply test systems incorporate custom board level instrumentation and hand wiring. However, power supply test systems based on standard products afford ...
... measurements. However, certain instruments are essential to all tests, regardless of the implementation. Some commercially available turnkey power supply test systems incorporate custom board level instrumentation and hand wiring. However, power supply test systems based on standard products afford ...
3 Ph. 11kV / 440 V 11kV / 440 V 50 Hz 500 kVA
... be maintained for a period not less than 24 hours for fluid and 1 hour for air, during which time no leakage shall occur. ...
... be maintained for a period not less than 24 hours for fluid and 1 hour for air, during which time no leakage shall occur. ...
Low-Cost Grid Connected Photovoltaic System Mahdi Salimi
... Usage of high-efficiency DC-DC converters has been investigated in [9] to improve efficiency. In 1994 instantaneous reactive power theory has been proposed by H.Akagi for controlling of Active Power Filters(APF)[10], and in reference [11] such a method is used for reactive compensation and harmonic ...
... Usage of high-efficiency DC-DC converters has been investigated in [9] to improve efficiency. In 1994 instantaneous reactive power theory has been proposed by H.Akagi for controlling of Active Power Filters(APF)[10], and in reference [11] such a method is used for reactive compensation and harmonic ...
Grounding and Bonding CEC-10 [rev-9]
... Where stray voltages are severe enough to present a problem in facilities housing livestock, neutral to earth reactors (commonly known as "tingle voltage filters) are permitted by Rule 10806(1). Neutral to earth reactors should not to be used until it has been determined that improperly installed, o ...
... Where stray voltages are severe enough to present a problem in facilities housing livestock, neutral to earth reactors (commonly known as "tingle voltage filters) are permitted by Rule 10806(1). Neutral to earth reactors should not to be used until it has been determined that improperly installed, o ...
Diode-connected BJT
... current (very often there is only one even in a large circuit): Only VBE and resistors are in this path. • Type of transistor will tell you the expected direction of current: npn - current sink, pnp - current source. • Identify current mirror configurations (Widlar, Wilson, etc.) and respective emit ...
... current (very often there is only one even in a large circuit): Only VBE and resistors are in this path. • Type of transistor will tell you the expected direction of current: npn - current sink, pnp - current source. • Identify current mirror configurations (Widlar, Wilson, etc.) and respective emit ...
HMC641 数据资料DataSheet下载
... The HMC641 is a broadband non-reflective GaAs PHEMT SP4T switch chip. Covering DC to 18 GHz, this switch offers high isolation and low insertion loss and extends the frequency coverage of Hittite’s SP4T switch product line. This switch also includes an on board binary decoder circuit which reduces t ...
... The HMC641 is a broadband non-reflective GaAs PHEMT SP4T switch chip. Covering DC to 18 GHz, this switch offers high isolation and low insertion loss and extends the frequency coverage of Hittite’s SP4T switch product line. This switch also includes an on board binary decoder circuit which reduces t ...
Product Summary
... efficiencies attained throughout the entire power range, the SKY77189 delivers unsurpassed talk-time advantages. The SKY77189 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency. A directional coupler is ...
... efficiencies attained throughout the entire power range, the SKY77189 delivers unsurpassed talk-time advantages. The SKY77189 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency. A directional coupler is ...
LT6402-20
... typically 30mA of supply current. If high, the LT6402 is disabled and draws typically 250µA. ...
... typically 30mA of supply current. If high, the LT6402 is disabled and draws typically 250µA. ...
Solar PV - Standard Plan - Microinverter
... combined system AC inverter output rating of 10 kW, with a maximum of 3 branch circuits, one PV module per inverter and with PV module ISC maximum of 10-A DC, installed on a roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to a single-phase AC s ...
... combined system AC inverter output rating of 10 kW, with a maximum of 3 branch circuits, one PV module per inverter and with PV module ISC maximum of 10-A DC, installed on a roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to a single-phase AC s ...
Cewe Digital Programmable Transducer
... Measurement method: It is possible to set the correct measurement method with two drop down toolbars. A picture will also display the proper way to install the transducer. All possible measurement variants are shown in Measuring principles (pg. 8). Analogue output curves: To configure the analogue o ...
... Measurement method: It is possible to set the correct measurement method with two drop down toolbars. A picture will also display the proper way to install the transducer. All possible measurement variants are shown in Measuring principles (pg. 8). Analogue output curves: To configure the analogue o ...
MAX1578/MAX1579 Complete Bias and White LED Power Supplies for Small TFT Displays
... The MAX1578/MAX1579 provide four regulated outputs to meet all the voltage requirements for small activematrix TFT-LCD displays in handheld devices where minimum external components and high efficiency are required. Each device consists of three advanced charge pumps for LCD bias power and a step-up ...
... The MAX1578/MAX1579 provide four regulated outputs to meet all the voltage requirements for small activematrix TFT-LCD displays in handheld devices where minimum external components and high efficiency are required. Each device consists of three advanced charge pumps for LCD bias power and a step-up ...
NMOS Transistor
... wrong value: NMOS transistors only pull up to VDD-Vtn, while PMOS transistors only pull down to |Vtp| The magnitude of the threshold drop is increased by the body effect Fully complementary transmission gates should be used where both 0’s and 1’s must be passed well ...
... wrong value: NMOS transistors only pull up to VDD-Vtn, while PMOS transistors only pull down to |Vtp| The magnitude of the threshold drop is increased by the body effect Fully complementary transmission gates should be used where both 0’s and 1’s must be passed well ...
... Stator winding insulation deterioration is a relatively slow process in which the time between when significant PD can be detected and when winding failure may occur, is usually two or more years. Thus, periodic measurements done once every six months or so are often adequate for detecting stator wi ...
136 KB - Socionext
... Customers are advised to consult with sales representatives before ordering. The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose of reference to show examples of operations and uses of FUJITSU SEMICONDUCTOR device; ...
... Customers are advised to consult with sales representatives before ordering. The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose of reference to show examples of operations and uses of FUJITSU SEMICONDUCTOR device; ...
chapter 1 - Portal UniMAP
... When AC voltage is applied to the primary winding of the transformer, an AC current will result i1 or i2 (current at load). The AC primary current i1 set up time varying magnetic flux f in the core. The flux links the secondary winding of the transformer. From the Faraday law, the emf will be ...
... When AC voltage is applied to the primary winding of the transformer, an AC current will result i1 or i2 (current at load). The AC primary current i1 set up time varying magnetic flux f in the core. The flux links the secondary winding of the transformer. From the Faraday law, the emf will be ...
Installation Instruction Sheet for Vision Site Small LED
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.