AN2834
... The analog power supply is used as the reference voltage for conversion. As the ADC output is the ratio between the analog signal voltage and the supply voltage, any noise on the analog reference will cause a change in the converted digital value. For example, with an analog reference of 3.3 V and a ...
... The analog power supply is used as the reference voltage for conversion. As the ADC output is the ratio between the analog signal voltage and the supply voltage, any noise on the analog reference will cause a change in the converted digital value. For example, with an analog reference of 3.3 V and a ...
enclosed meters
... The Eaton enclosed meter line provides a complete energy metering and data acquisition solution in a single enclosure. Designed for Eaton’s IQ 35M, IQ 150, IQ 250/260, and Power Xpert® 2000/4000/6000/8000 and Multi-Point Meters, Eaton’s enclosed meter line offers mounting and installation flexibilit ...
... The Eaton enclosed meter line provides a complete energy metering and data acquisition solution in a single enclosure. Designed for Eaton’s IQ 35M, IQ 150, IQ 250/260, and Power Xpert® 2000/4000/6000/8000 and Multi-Point Meters, Eaton’s enclosed meter line offers mounting and installation flexibilit ...
Owner`s Manual
... is isolated from the common ground. This gives you Balanced Power with Ground Isolation to help eliminate annoying ground loops in your system. Analog Components: Two banks of independently filtered outlets (banks 1 and 2) are designed for your analog components. These outlet banks utilize “Balanced ...
... is isolated from the common ground. This gives you Balanced Power with Ground Isolation to help eliminate annoying ground loops in your system. Analog Components: Two banks of independently filtered outlets (banks 1 and 2) are designed for your analog components. These outlet banks utilize “Balanced ...
ARQ_AMICSA2016_LVDS_Final
... in communication among spacecraft and satellite onboard systems during a mission. LVDS (Low-Voltage Differential Signaling) Drivers and Receivers are key devices to provide means of sending/receiving data along twisted pair cable at very high data-rates with low power and excellent EMI performance. ...
... in communication among spacecraft and satellite onboard systems during a mission. LVDS (Low-Voltage Differential Signaling) Drivers and Receivers are key devices to provide means of sending/receiving data along twisted pair cable at very high data-rates with low power and excellent EMI performance. ...
FEASIBILITY OF A PLASMA CONTACT FOR FARADAY
... (http://www.mersen.com/uploads/tx_mersen/5-carbon-brush-technical-guidemersen.pdf). The mechanical factors include surface tribology of contacting surface – ideally the contact surface should neither be too smooth nor too rough, variable friction co-efficient of the brush, vibrations of the device ...
... (http://www.mersen.com/uploads/tx_mersen/5-carbon-brush-technical-guidemersen.pdf). The mechanical factors include surface tribology of contacting surface – ideally the contact surface should neither be too smooth nor too rough, variable friction co-efficient of the brush, vibrations of the device ...
Performing Very Low Frequency Capacitance
... Capacitance measurements on semiconductor devices are usually made using an AC technique with a bridge-type instrument. These AC instruments typically make capacitance and impedance measurements at frequencies ranging from megahertz down to possibly tens of hertz. However, even lower frequency capac ...
... Capacitance measurements on semiconductor devices are usually made using an AC technique with a bridge-type instrument. These AC instruments typically make capacitance and impedance measurements at frequencies ranging from megahertz down to possibly tens of hertz. However, even lower frequency capac ...
Example Temperature Measurement Applications Using the
... sources are used to provide symmetry and compensate for mismatch through the RTD wiring. The ADS1247/8 current sources are connected to the two channels configured with the two RTD terminals by setting the appropriate bits in the IDAC1 register. The current value can be chosen by setting the ISELT b ...
... sources are used to provide symmetry and compensate for mismatch through the RTD wiring. The ADS1247/8 current sources are connected to the two channels configured with the two RTD terminals by setting the appropriate bits in the IDAC1 register. The current value can be chosen by setting the ISELT b ...
Wind Farm Grid Connection Code.
... reactive power must be below 40 % of Rated Power of the wind turbine generator and the consumption of active power must be below 30 % of Rated Power of the wind turbine generator in each grid cycle (20 ms). After fault clearance the active power output of the Wind Farm must reach the same level as b ...
... reactive power must be below 40 % of Rated Power of the wind turbine generator and the consumption of active power must be below 30 % of Rated Power of the wind turbine generator in each grid cycle (20 ms). After fault clearance the active power output of the Wind Farm must reach the same level as b ...
TJF1052i CAN 1. General description
... interface between a Controller Area Network (CAN) protocol controller and the physical two-wire CAN bus. The TJF1052i is specifically targeted at industrial applications, where galvanic isolation barriers are needed between the high- and low-voltage parts. Safety: Isolation is required for safety re ...
... interface between a Controller Area Network (CAN) protocol controller and the physical two-wire CAN bus. The TJF1052i is specifically targeted at industrial applications, where galvanic isolation barriers are needed between the high- and low-voltage parts. Safety: Isolation is required for safety re ...
hysteresis current control technique for three phase induction motor
... Hysteresis can be define as the dependence of a system which is not only on its current environment but also on its past environment. In other words, it is deficiency or lagging behind [12]. This dependence arises because of the system could be more than one internal state. To predict its future dev ...
... Hysteresis can be define as the dependence of a system which is not only on its current environment but also on its past environment. In other words, it is deficiency or lagging behind [12]. This dependence arises because of the system could be more than one internal state. To predict its future dev ...
on the damper cage bars` currents calculation for salient pole large
... With the above presented relations, all the rotor parameters were referred to the stator side. Thus, if a p.u. system is adopted, than only the stator reference system will be used. Independently from the number of damper bars per pole, a voltage equation system with 5 equation and 5 unknown quantit ...
... With the above presented relations, all the rotor parameters were referred to the stator side. Thus, if a p.u. system is adopted, than only the stator reference system will be used. Independently from the number of damper bars per pole, a voltage equation system with 5 equation and 5 unknown quantit ...
B25668A6107A375 - uri=media.digikey
... customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual se ...
... customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual se ...
Simple Analog Signal Chaotic Masking and Recovery
... chaos generators would un-synch briefly for about 1-3 ms then re-align. This occurred only when the buffer was included in the synch chain. Without the buffer, the simulation would not go past 500 ms without losing chaos and reverting to periodicity. I speculate that current back feed would creep fr ...
... chaos generators would un-synch briefly for about 1-3 ms then re-align. This occurred only when the buffer was included in the synch chain. Without the buffer, the simulation would not go past 500 ms without losing chaos and reverting to periodicity. I speculate that current back feed would creep fr ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.