MC100LVEL11DTR2G中文资料
... or authorized for use as components in systems intended for surgical implant into the body, or other applicationsintended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. ...
... or authorized for use as components in systems intended for surgical implant into the body, or other applicationsintended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. ...
TPS62420-Q1 数据资料 dataSheet 下载
... batteries. The device is also suitable to operate from a standard 3.3-V or 5-V voltage rail. With the EasyScale™ serial interface the output voltages can be modified during operation. It therefore supports Dynamic Voltage Scaling for low power DSP and processors. The TPS62420 operates at 2.25-MHz fi ...
... batteries. The device is also suitable to operate from a standard 3.3-V or 5-V voltage rail. With the EasyScale™ serial interface the output voltages can be modified during operation. It therefore supports Dynamic Voltage Scaling for low power DSP and processors. The TPS62420 operates at 2.25-MHz fi ...
MAX3471 1.6µA, RS-485/RS-422, Half-Duplex, Differential Transceiver for Battery-Powered Systems ________________General Description
... Length = tRISE / (10 x 1.5ns/foot) where tRISE is the transmitter’s rise time. For example, the MAX3471’s rise time is typically 1.3µs, which results in excellent waveforms with a stub length up to 82 feet. In general, systems operate well with longer unterminated stubs, even with severe reflections ...
... Length = tRISE / (10 x 1.5ns/foot) where tRISE is the transmitter’s rise time. For example, the MAX3471’s rise time is typically 1.3µs, which results in excellent waveforms with a stub length up to 82 feet. In general, systems operate well with longer unterminated stubs, even with severe reflections ...
LT1739 - Dual 500mA, 200MHz xDSL Line Driver Amplifier
... two logic control inputs can set two or four different operating modes. The logic inputs add or subtract current to the SHDN input to set the operating current. The one logic input example selects the supply current to be either full power, 10mA per amplifier or just 2mA per amplifier, which signifi ...
... two logic control inputs can set two or four different operating modes. The logic inputs add or subtract current to the SHDN input to set the operating current. The one logic input example selects the supply current to be either full power, 10mA per amplifier or just 2mA per amplifier, which signifi ...
MAX3385E ±15kV ESD-Protected, 3.0V to 5.5V, Low-Power, ________________General Description
... 100pF capacitor charged to the ESD voltage of interest, which is then discharged into the test device through a 1.5kΩ resistor. IEC 1000-4-2 The IEC 1000-4-2 standard covers ESD testing and performance of finished equipment; it does not specifically refer to integrated circuits. The MAX3385E helps y ...
... 100pF capacitor charged to the ESD voltage of interest, which is then discharged into the test device through a 1.5kΩ resistor. IEC 1000-4-2 The IEC 1000-4-2 standard covers ESD testing and performance of finished equipment; it does not specifically refer to integrated circuits. The MAX3385E helps y ...
Medium Voltage Switchgear - UW Facility Services
... Equipment must match existing campus switchgear used in similar applications. ...
... Equipment must match existing campus switchgear used in similar applications. ...
POWER SYSTEM HARMONICS A Reference Guide to Causes
... CAUSES OF HARMONICS .......................................................... 2 POTENTIAL EFFECTS OF HARMONICS ..................................... 3 ...
... CAUSES OF HARMONICS .......................................................... 2 POTENTIAL EFFECTS OF HARMONICS ..................................... 3 ...
AC Induction Motor Data
... magnetic field within the motor is rotating. It is also approximately the speed that the motor will run under no load conditions. Synchronized speed formula is the Number of (HZ) cycles (x) seconds in a minute (x) two (for the positive and negative pulses in the cycle) divided by the number of poles ...
... magnetic field within the motor is rotating. It is also approximately the speed that the motor will run under no load conditions. Synchronized speed formula is the Number of (HZ) cycles (x) seconds in a minute (x) two (for the positive and negative pulses in the cycle) divided by the number of poles ...
HMC241LP3 - Hittite Microwave Corporation
... The HMC241LP3 & HMC241LP3E are general purpose non-reflective SP4T switches in low cost leadless surface mount packages. Covering DC - 4 GHz, this switch offers high isolation and has a low insertion loss of 0.7 dB at 2 GHz. The switch offers a single positive bias and true TTL/CMOS compatibility. A ...
... The HMC241LP3 & HMC241LP3E are general purpose non-reflective SP4T switches in low cost leadless surface mount packages. Covering DC - 4 GHz, this switch offers high isolation and has a low insertion loss of 0.7 dB at 2 GHz. The switch offers a single positive bias and true TTL/CMOS compatibility. A ...
Softstarter Handbook
... In this book the focus has been placed on the squirrel cage motor, the most common type of motor on the market. It is relatively cheap and the maintenance cost is normally low. There are many different manufacturers represented on the market, selling at various prices. Not all motors have the same p ...
... In this book the focus has been placed on the squirrel cage motor, the most common type of motor on the market. It is relatively cheap and the maintenance cost is normally low. There are many different manufacturers represented on the market, selling at various prices. Not all motors have the same p ...
PSPICE Lecture #2 – AC Circuit Analysis
... PSPICE Lecture - AC Circuits 2) Add voltage and current printers • An AC sweep analysis only calculates DC node voltages (typically all 0) by default. In order to find phasor voltages and currents, we must add printers. • Voltage Printers - must be placed in parallel with the desired component(s) • ...
... PSPICE Lecture - AC Circuits 2) Add voltage and current printers • An AC sweep analysis only calculates DC node voltages (typically all 0) by default. In order to find phasor voltages and currents, we must add printers. • Voltage Printers - must be placed in parallel with the desired component(s) • ...
MAX110/MAX111 Low-Cost, 2-Channel, ±14-Bit Serial ADCs General Description ____________________________Features
... by power-supply rejection tests. Tests are performed at VDD = 5V and VSS = -5V (MAX110). Note 2: 32,768 LSBs cover an input voltage range of ±VREF (15 bits). An additional bit (OFL) is set for VIN > VREF. Note 3: Guaranteed by design. Not subject to production testing. Note 4: DNL is less than ±2 co ...
... by power-supply rejection tests. Tests are performed at VDD = 5V and VSS = -5V (MAX110). Note 2: 32,768 LSBs cover an input voltage range of ±VREF (15 bits). An additional bit (OFL) is set for VIN > VREF. Note 3: Guaranteed by design. Not subject to production testing. Note 4: DNL is less than ±2 co ...
MAX1968/MAX1969 Power Drivers for Peltier TEC Modules General Description Features
... reduce component size and noise. The MAX1968 operates from a single supply and provides bipolar ±3A output by biasing the TEC between the outputs of two synchronous buck regulators. Bipolar operation allows for temperature control without “dead zones” or other nonlinearities at low load currents. Th ...
... reduce component size and noise. The MAX1968 operates from a single supply and provides bipolar ±3A output by biasing the TEC between the outputs of two synchronous buck regulators. Bipolar operation allows for temperature control without “dead zones” or other nonlinearities at low load currents. Th ...
cautions for proper use of aluminum electrolytic capacitor
... 8)Consideration for Circuit Design ・In designing a printed circuit board (PCB) with Aluminum Electrolytic Capacitors, the following matters should be ensured: ①Alignment of through-hole pitch on the circuit with radial lead pitch of each capacitor. ②Avoid wiring or circuit pattern around the capacit ...
... 8)Consideration for Circuit Design ・In designing a printed circuit board (PCB) with Aluminum Electrolytic Capacitors, the following matters should be ensured: ①Alignment of through-hole pitch on the circuit with radial lead pitch of each capacitor. ②Avoid wiring or circuit pattern around the capacit ...
Capacitor unbalance protection for blocks in double
... element that the fuse is designed to isolate if the element becomes faulty. After the breakdown of an element, the fuse connected to it will blow and isolate it from the remaining part of the capacitor, which allows the unit to continue in service. The blowing of one or more fuses decreases the capa ...
... element that the fuse is designed to isolate if the element becomes faulty. After the breakdown of an element, the fuse connected to it will blow and isolate it from the remaining part of the capacitor, which allows the unit to continue in service. The blowing of one or more fuses decreases the capa ...
APT 2.4kV-15kV Manual Transfer Switchgear (MV MTS)
... your project. Also delete any other items or paragraphs that does not apply. voltage, ampacity, interrupting rating, enclosure type, and ...
... your project. Also delete any other items or paragraphs that does not apply. voltage, ampacity, interrupting rating, enclosure type, and ...
AUTOMOTIVE ELECTRICAL CIRCUITS AND WIRING
... COLD-CRANKING RATING.- The cold-cranking rating determines how much current in amperes the battery can deliver for thirty seconds at 0° F while maintaining terminal voltage of 7.2 volts or 1.2 volts per cell. This rating indicates the ability of the battery to crank a specific engine (based on start ...
... COLD-CRANKING RATING.- The cold-cranking rating determines how much current in amperes the battery can deliver for thirty seconds at 0° F while maintaining terminal voltage of 7.2 volts or 1.2 volts per cell. This rating indicates the ability of the battery to crank a specific engine (based on start ...
$doc.title
... There are two basic approaches to line termination: source termination and end termination. Both schemes will result in a stable signal at the far end of the line after one line delay. Source termination, however, results in a stable signal up to two line delays for loads at intermediate points on t ...
... There are two basic approaches to line termination: source termination and end termination. Both schemes will result in a stable signal at the far end of the line after one line delay. Source termination, however, results in a stable signal up to two line delays for loads at intermediate points on t ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.