• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Group 1
Group 1

lecture chapter 26
lecture chapter 26

... or loss of energy depends on the resistance. The sum of the voltage drops across the resistors equals the battery terminal voltage: or total loss of energy through the R’s =original Vab ...
Universal input voltage power supply for ESBT based breaker and
Universal input voltage power supply for ESBT based breaker and

... terminated during the switching cycle. If this happens for several pulses, the feedback loop increases the error signal and produces a higher energy that is transferred to the secondary side. As a result, a higher output pulse is generated and again prematurely ended. Another disadvantage of a filte ...
SMP18 Octal Sample-and-Hold with Multiplexed Input
SMP18 Octal Sample-and-Hold with Multiplexed Input

... range but have limited current sinking capability near VSS. In split supply operation, symmetrical output swings can be obtained by restricting the output range to 2 V from either supply. ...
LT1580(-2.5) - Linear Technology
LT1580(-2.5) - Linear Technology

... regulators have become more common in desktop computer systems as microprocessor manufacturers have moved away from 5V only CPUs. A wide range of supply requirements exists today with new voltages just over the horizon. In many cases the input-output differential is very small, effectively disqualif ...
NUD4011 Low Current LED Driver
NUD4011 Low Current LED Driver

#2093
#2093

... Order from Catalog Numbers Above ...
MAX4626/MAX4627/MAX4628 0.5 SPST Analog Switches , Low-Voltage, Single-Supply
MAX4626/MAX4627/MAX4628 0.5 SPST Analog Switches , Low-Voltage, Single-Supply

... protection circuitry. When the voltage drop across the on switch reaches 0.6V (typ), the internal circuitry activates. The current limit is not instantaneous, but rather integrates over time so that current limiting will not activate under momentary short-circuit conditions encountered when the swit ...
Lab PDF
Lab PDF

Tech Sheet - Alberta Governor Service
Tech Sheet - Alberta Governor Service

... functions and features for multiple application with up to 14 generators, each with a maximum individual rating of 16MW. Whether isolated or in parallel with the utility this device was designed for generators and switchgear equipment that require independent protection. The MFR 3 digitally measures ...
EE 340 – Transmission Lines
EE 340 – Transmission Lines

... • For long lines, both the shunt capacitance and the series impedance must be treated as distributed quantities. The voltages and currents on the line are found by solving differential equations of the line. • However, it is possible to model a long transmission line as a π model with a modified ser ...
Datasheet Danfoss TLX8
Datasheet Danfoss TLX8

... number of strings can be reduced, resulting in significantly lower installation costs. Multiple DC input also adds flexibility and allows you to design with any number of strings. For example, if you have 4 strings where one is different from the rest, you can couple 3 in parallel to two inputs and ...
Models WA5A, WA5V Distributor (with Square Root
Models WA5A, WA5V Distributor (with Square Root

... Read the parameter [C04: ZERO ADJ] and check the input value. Select “INC” or “DEC” in the parameter [C04: ZERO ADJ] to adjust. •Adjust so that the indicated value and measured value of [C04: ZERO ADJ] become equal. INC: Increase (Adjusts the increased value of the input [voltage] value) DEC: Decrea ...
Amp Enable Outputs
Amp Enable Outputs

... limit the high voltage of the output to the analog positive supply voltage, usually +15V. In order to defeat this protection and allow the sinking outputs to be pulled to 24V, remove the IC from location U11 on the PMAC PC board. The positive supply voltage for the IC, pin 10, must be bent backward ...
ICL7652 Advanced LinCMOSTM PRECISION
ICL7652 Advanced LinCMOSTM PRECISION

... capacitors and standoffs are recommended for operation at T A = 125°C. In addition, guardbands around the capacitor connections on both sides of the printed circuit board are recommended to alleviate problems caused by surface leakage on circuit boards. Capacitors with high dielectric absorption ten ...
ASNT1012 Reconfigurable MUX CMU
ASNT1012 Reconfigurable MUX CMU

... ASNT6114-KMC is a temperature stable active analog signal splitter 1-to-2 and is intended for use in highspeed interleaved ADC or similar systems. The IC shown in Fig. 1 can receive a broad-band analog signal at its differential input “dp/dn” and effectively distribute it to two separate phase match ...
Industrial / Power
Industrial / Power

... • Precision molded in gold colored, flame retardant, thermosetting epoxy resin • Laser marked for improved legibility, and tapered end on positive terminal • Standard orders are taped and reeled; under 500 pieces are ammo packed ...
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair

... as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can be triggered during the load transition. To avoid ...
Electric Circuits
Electric Circuits

... Think of Christmas lights. What happens when one light burns out? ...
RSB16F2
RSB16F2

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of which would directly endange ...
introduction
introduction

Lab-8, Measure Magnetic Field
Lab-8, Measure Magnetic Field

... fully inserted in the coil. Since the flux is related to only these two values and not the details of motion, the magnitude of the field is obtained from the voltage integrated over the motion. In this lab you will build a magnetometer using on an integrating op amp circuit and coil of wire. Items n ...
Test 3 will be on Chapters 21 and 22
Test 3 will be on Chapters 21 and 22

... Notes for Test 4 Test 4 will be on Chapters 23 and 24. ...
CC8 Contractor's Choice FasTest spec sheet
CC8 Contractor's Choice FasTest spec sheet

... The CC8 Contractor's Choice FasTest(TM) High Capacity Emergency Lighting Unit is an affordable, attractive alternative to standard white two-headed emergency lighting units. All components snap together to facilitate installation in 5 minutes or less. Field versatility is not sacrificed for cost, bo ...
MGE Power Management Modules
MGE Power Management Modules

... of branch circuit breakers due to overloading is a leading threat to reliability. The Branch Circuit Current Monitor scans the current of all panel board branch circuits, alarming when current levels exceed a user programmable set point before the circuit breaker is at risk of tripping. Branch circu ...
< 1 ... 894 895 896 897 898 899 900 901 902 ... 1376 >

Rectifier



A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report