• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
How will the 17th Edition Amendment 3 change the way you test
How will the 17th Edition Amendment 3 change the way you test

... from January 1 2015. There will be a 6 month transition period where electrical contractors can install to amendment 2 or amendment 3, after which it will be a requirement that all electrical installations designed and periodically tested will have to comply with the changes. There are many changes ...
here - Transaction on electrical engineering
here - Transaction on electrical engineering

Parametric Average-Value Model of Synchronous Machine
Parametric Average-Value Model of Synchronous Machine

... to model an inductorless rectifier-machine system in [12]. In each case ([7]–[11]), the analytical development is based upon a single switching pattern (conduction and commutation intervals) and, therefore, is valid only for that operating mode. An approach similar to [8] has recently been used in [ ...
TPS54872 数据资料 dataSheet 下载
TPS54872 数据资料 dataSheet 下载

... signals. Noise injected between the two grounds can degrade the performance of the TPS54872, particularly at higher output currents. Ground noise on an analog ground plane can also cause problems with some of the control and bias signals. For these reasons, separate analog and power ground traces ar ...
Series vs. Parallel - Energizer Technical Information
Series vs. Parallel - Energizer Technical Information

... Batteries connected in parallel should be at the same state of discharge. If batteries at different states of discharge are installed into a device using a parallel battery configuration, the battery with the higher voltage will charge the battery with lower voltage until voltage equilibrium is reac ...
Dual-Output Low-Dropout Voltage Regulators
Dual-Output Low-Dropout Voltage Regulators

... outputs in a compact package and incorporating stability with 10-μF low ESR output capacitors. The TPS767D3xx family of dual voltage regulators is designed primarily for DSP applications. These devices can be used in any mixed-output voltage application, with each regulator supporting up to 1 A. Dua ...
Protect 2.33 2.0 - AEG Power Solutions
Protect 2.33 2.0 - AEG Power Solutions

... For all unit models. Neutral is permanently connected from input to output terminals. • The authorized operator must transfer the output to bypass first, and then turn-on maintenance bypass. Then input, output, and battery switch can be turned off, and also neutral disconnector can be opened. If ba ...
TS30011/12/13 High Efficiency 1A/2A/3A Current-Mode
TS30011/12/13 High Efficiency 1A/2A/3A Current-Mode

... This is the switching node of the regulator. It should be connected directly to the 4.7uH inductor with a wide, short trace and to one end of the Bootstrap capacitor. It is switching between VCC and PGND at the switching frequency. Ground, GND This ground is used for the majority of the device inclu ...
optimal location of voltage regulators in radial distribution
optimal location of voltage regulators in radial distribution

... Voltage profile can be improved by the use of analytical tools such as optimal power flow, voltage stability, failure indicators analysis etc, and by the installation of devices such as fixed and controlled capacitors banks, automatic voltage regulators and transformers with on-load tap changers, [2 ...
HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC
HIGH STEP–UP DC––DC CONVERTER FOR AC PHOTOVOLTAIC

Fundamentals of Linear Electronics Integrated & Discrete
Fundamentals of Linear Electronics Integrated & Discrete

Microwave Power Combiners
Microwave Power Combiners

... •Gets rid of even harmonics can be used for very wide bandwidths (more than x2) in situations where filtering cannot be done •Push pull leads to more uniform current draw from supply, so grounding source is not a big problem ...
MAX9115 Single LVDS Line Receiver in SC70 General Description Features
MAX9115 Single LVDS Line Receiver in SC70 General Description Features

... LVDS is intended for point-to-point communication over a controlled-impedance medium as defined by the ANSI TIA/EIA-644 and IEEE 1596.3 standards. LVDS uses a lower voltage swing than other common communication standards, achieving higher data rates with reduced power consumption while reducing EMI ...
FMMT6520 Features and Benefits Mechanical Data
FMMT6520 Features and Benefits Mechanical Data

... Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically n ...
800mA Low Dropout Positive Regulator with Current Source and
800mA Low Dropout Positive Regulator with Current Source and

Data Sheet - Profusion plc
Data Sheet - Profusion plc

... COF CS ...
2013 Fall Catalog - Global Specialties
2013 Fall Catalog - Global Specialties

... has user selectable ranges from 0-130VAC @ 4 Amps and 0-260VAC @ 2 Amps of continuous current. All designs feature a super isolation transformer which is triple shielded from the input line for maximum protection against shock hazard. A convenient front panel plug accepts a probe for measuring leaka ...


... level. An alternator control unit (ACU) combines the voltage regulator with other functions, such as over voltage protection. A “Type B” regulator excites the field of the alternator by providing controlled power to one side of the alternator field, with the other side grounded. The aircraft chargin ...
MAX1832–MAX1835 High-Efficiency Step-Up Converters with Reverse Battery Protection General Description
MAX1832–MAX1835 High-Efficiency Step-Up Converters with Reverse Battery Protection General Description

... MAX1834/MAX1835 startup voltage (1.65V) is slightly higher, due to the voltage across the PFET body diode. The SHDN pin has reverse battery protection. In shutdown, the MAX1832/MAX1833 connect the battery input to the output through the inductor and the internal synchronous rectifier PFET. This allo ...
Datasheet 6N138/ 6N139
Datasheet 6N138/ 6N139

... 300 % minimum current transfer ratio with an LED current of 1.6 mA enables operation with one unit load-in and one unit load-out with a 2.2 kΩ pull-up resistor. The 6N139 is best suited for low power logic applications involving CMOS and low power TTL. A 400 % current transfer ratio with only 0.5 mA ...
When to use a three-phase pad-mounted transformer COOPER POWER SERIES
When to use a three-phase pad-mounted transformer COOPER POWER SERIES

... land requirements and associated costs of obtaining rights-of-way and permits are reduced. Additionally, because they are tamper-proof and self-contained, pad-mounted transformers can be installed in unsecured areas, saving the additional cost and space of a fence or enclosure. Access for maintenanc ...
MAX6338 Quad Voltage Monitor in µMAX Package General Description Features
MAX6338 Quad Voltage Monitor in µMAX Package General Description Features

... with other logic devices. The MAX6338 can monitor power supplies with either 5% or 10% tolerance specifications, depending on the selected version. An additional high-input-impedance comparator option can be used as an adjustable voltage monitor, general-purpose comparator, or digital level translat ...
1.1 An introductory overview of power electronic devices
1.1 An introductory overview of power electronic devices

Sample Report
Sample Report

... The transformer is loaded to approximately 40% of its rated capacity of 75kVA. Figure 1 shows the time plot for the total KVA during the 7-day monitoring period. Note that the loading on the transformer ranges from approximately 27.3kVA to a high of 37.1kVA or about 40% of the transformer’s rated ca ...
PowerPoint-presentation
PowerPoint-presentation

< 1 ... 819 820 821 822 823 824 825 826 827 ... 1376 >

Rectifier



A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report