Aalborg Universitet and Harmonics in Microgrids
... The scheme of [4] is based on a two-inverter (shunt-series) interface converter to control power flow and to compensate the voltage unbalance. This structure can be unattractive due to high cost and volume of the interface converter. In [5], each DG unit of microgrid is controlled as a negative sequ ...
... The scheme of [4] is based on a two-inverter (shunt-series) interface converter to control power flow and to compensate the voltage unbalance. This structure can be unattractive due to high cost and volume of the interface converter. In [5], each DG unit of microgrid is controlled as a negative sequ ...
Designing Switching Voltage Regulators with
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
AND9056 - High Performance IGBT for Induction Heating
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
Are you violating your op amp`s input- common-mode range?
... One special case worth mentioning for wide input ranges is the rail-to-rail-input op amp. Although the name implies an op amp whose input can span the entire supply-rail range, not all rail-to-ral-input devices cover the entire supply range, as you might assume. Many rail-to-rail-input op amps, suc ...
... One special case worth mentioning for wide input ranges is the rail-to-rail-input op amp. Although the name implies an op amp whose input can span the entire supply-rail range, not all rail-to-ral-input devices cover the entire supply range, as you might assume. Many rail-to-rail-input op amps, suc ...
Spintronics Integrating magnetic materials with semiconductors
... fraction of a second signals the drive’s read/write heads to temporarily park, helping prevent contact with the disk drive until the system is stabilized ...
... fraction of a second signals the drive’s read/write heads to temporarily park, helping prevent contact with the disk drive until the system is stabilized ...
GB3411111120
... Fig. 1. Circuit configuration of the proposed PV charger partial charging modewherein the available maximum PV power is larger than theload power and the excessive power will charge the battery, butthe charging current is still less than the preset charge The circuit configuration of the proposed PV ...
... Fig. 1. Circuit configuration of the proposed PV charger partial charging modewherein the available maximum PV power is larger than theload power and the excessive power will charge the battery, butthe charging current is still less than the preset charge The circuit configuration of the proposed PV ...
Design and Simulation by Photovoltaic System with Tapped
... The second inverter analyzed was proposed by Kusakawa et al. [13], this converter operates with PWM signal and hard switching technique and control on both sides: on one hand you have the DC-DC conversion and on the other hand the inverter, it eliminates asymmetry problems. Furthermore, this inverte ...
... The second inverter analyzed was proposed by Kusakawa et al. [13], this converter operates with PWM signal and hard switching technique and control on both sides: on one hand you have the DC-DC conversion and on the other hand the inverter, it eliminates asymmetry problems. Furthermore, this inverte ...
Digital Thermometer
... approximately 180K ohms at freezing to 2.5K at boiling. When connected in series with a 180 K ohm fixed resistor, the output voltage as a function of the thermistor resistance (or the temperature), is: (V+) 180K Vout = --------------------Rth + 180K This is the voltage divider equation. Vout is conn ...
... approximately 180K ohms at freezing to 2.5K at boiling. When connected in series with a 180 K ohm fixed resistor, the output voltage as a function of the thermistor resistance (or the temperature), is: (V+) 180K Vout = --------------------Rth + 180K This is the voltage divider equation. Vout is conn ...
MS Supplies Technical Description Template
... Each of the three converter units shall be composed of the following components: a) One power transformer 18/2 kV 2.5 MVA (not included in the scope of supply) b) One AC/DC Active Front End (AFE) sinusoidal rectifier. This converter will rectify the AC voltage and control the power flow from AC to D ...
... Each of the three converter units shall be composed of the following components: a) One power transformer 18/2 kV 2.5 MVA (not included in the scope of supply) b) One AC/DC Active Front End (AFE) sinusoidal rectifier. This converter will rectify the AC voltage and control the power flow from AC to D ...
RF2173 0
... the output stage is approximately 1.2Ω. This is the load at the output collector, and is created by the series inductance formed by the output bond wires, vias, and microstrip, and 2 shunt capacitors external to the part. The optimum load impedance at the RF Output pad is 1.5-j1.7Ω. With this match, ...
... the output stage is approximately 1.2Ω. This is the load at the output collector, and is created by the series inductance formed by the output bond wires, vias, and microstrip, and 2 shunt capacitors external to the part. The optimum load impedance at the RF Output pad is 1.5-j1.7Ω. With this match, ...
June 2006 Dual Step-Up Converter Drives White LEDs with 1000:1
... PWM dimming ratio with 100Hz PWM frequency—fast enough to avoid visible flicker. For instance, a combination of two LT3486s driving four LED strings (R-G-G-B) in a top-end display provides 1000:1 dimming while maintaining the true-color of the display even during very dim nighttime operation. When a ...
... PWM dimming ratio with 100Hz PWM frequency—fast enough to avoid visible flicker. For instance, a combination of two LT3486s driving four LED strings (R-G-G-B) in a top-end display provides 1000:1 dimming while maintaining the true-color of the display even during very dim nighttime operation. When a ...
FSQ0370RNA, FSQ0370RLA Green Mode Fairchild Power Switch (FPS™) FSQ0370RNA / FSQ0370RLA
... the SenseFET when the maximum PWM duty cycle is attained. If the output consumes more than this maximum power, the output voltage (VO) decreases below its nominal voltage. This reduces the current through the optocoupler LED, which also reduces the optocoupler transistor current, thus increasing the ...
... the SenseFET when the maximum PWM duty cycle is attained. If the output consumes more than this maximum power, the output voltage (VO) decreases below its nominal voltage. This reduces the current through the optocoupler LED, which also reduces the optocoupler transistor current, thus increasing the ...
SINGLE-SUPPLY RAIL-TO-RAIL OPERATIONAL AMPLIFIERS OPA340-EP FEATURES SUPPORTS DEFENSE, AEROSPACE,
... The OPA340 rail-to-rail CMOS operational amplifier is optimized for low-voltage, single-supply operation. Rail-to-rail input/output and high-speed operation make it ideal for driving sampling analog-to-digital (A/D) converters. The OPA340 is also well-suited for general purpose and audio application ...
... The OPA340 rail-to-rail CMOS operational amplifier is optimized for low-voltage, single-supply operation. Rail-to-rail input/output and high-speed operation make it ideal for driving sampling analog-to-digital (A/D) converters. The OPA340 is also well-suited for general purpose and audio application ...
Electrical Circuits Lab. 0903219 Series RLC Resonance Circuit
... cases depending on the source operating frequency f : a- Case 1: f = fr As mentioned before when f = fr XL=XC so VL=VC and they are equal in magnitude and out of phase so VC and VL will cancel each other's effect and the circuit becomes a resistive circuit and the phase shift Ө equal zero Figure (3) ...
... cases depending on the source operating frequency f : a- Case 1: f = fr As mentioned before when f = fr XL=XC so VL=VC and they are equal in magnitude and out of phase so VC and VL will cancel each other's effect and the circuit becomes a resistive circuit and the phase shift Ө equal zero Figure (3) ...
MAX5188/MAX5191 Dual, 8-Bit, 40MHz, Current/Voltage, Alternate-Phase Output DACs General Description
... The MAX5188/MAX5191 also employ a control amplifier, designed to simultaneously regulate the full-scale output current IFS for both MAX5188/MAX5191 outputs. The output current is calculated as follows: IFS = 8 ✕ IREF where I REF is the reference output current (I REF = VREFO / RSET) and IFS is the f ...
... The MAX5188/MAX5191 also employ a control amplifier, designed to simultaneously regulate the full-scale output current IFS for both MAX5188/MAX5191 outputs. The output current is calculated as follows: IFS = 8 ✕ IREF where I REF is the reference output current (I REF = VREFO / RSET) and IFS is the f ...
2SC2347 TV UHF Oscillator Applications TV VHF Mixer Applications Maximum Ratings
... spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained he ...
... spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained he ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.