Neutral Grounding
... neutral may not be available, particularly in many older low voltage systems and a significant number of existing medium voltage systems. To avoid the high cost of replacing a source transformer, an existing delta-connected system can be grounded using a zigzag transformer to form an artificial neut ...
... neutral may not be available, particularly in many older low voltage systems and a significant number of existing medium voltage systems. To avoid the high cost of replacing a source transformer, an existing delta-connected system can be grounded using a zigzag transformer to form an artificial neut ...
TPS70402 数据资料 dataSheet 下载
... (that is, logic high) after a 120-ms delay when both of the following conditions are met. First, VIN1 must be above the undervoltage condition. Second, the manual reset (MR) pin must be in a high impedance state. To monitor VOUT1, the PG1 output pin can be connected to MR. To monitor VOUT2, the PG2 ...
... (that is, logic high) after a 120-ms delay when both of the following conditions are met. First, VIN1 must be above the undervoltage condition. Second, the manual reset (MR) pin must be in a high impedance state. To monitor VOUT1, the PG1 output pin can be connected to MR. To monitor VOUT2, the PG2 ...
SP1486E 数据资料DataSheet下载
... SP1486E is a half duplex differential line transceiver suitable for high speed bidirectional communication on multipoint bus transmission lines. Each device contains one differential driver and one differential receiver. Devices comply with TIA/EIA-485 and TIA/EIA-422 standards and also meet the hig ...
... SP1486E is a half duplex differential line transceiver suitable for high speed bidirectional communication on multipoint bus transmission lines. Each device contains one differential driver and one differential receiver. Devices comply with TIA/EIA-485 and TIA/EIA-422 standards and also meet the hig ...
DAC2902 数据资料 dataSheet 下载
... The two converter channels within the DAC2902 consist of two independent, 12-bit, parallel data ports. Each DAC channel is controlled by its own set of write (WRT1, WRT2) and clock (CLK1, CLK2) inputs. Here, the WRT lines control the channel input latches and the CLK lines control the DAC latches. T ...
... The two converter channels within the DAC2902 consist of two independent, 12-bit, parallel data ports. Each DAC channel is controlled by its own set of write (WRT1, WRT2) and clock (CLK1, CLK2) inputs. Here, the WRT lines control the channel input latches and the CLK lines control the DAC latches. T ...
AT17 Series FPGA Configuration E PROM AT17C65 AT17C128
... Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for ...
... Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for ...
PV150 Comparison Document
... The electrical output will vary significantly with changes in the level of in-plane irradiance. Solar PV panel manufacturers quote the electrical output at standard test conditions (STC) with an irradiance level of 1000W/m2. Therefore, when commissioning a PV system, it is necessary to measure the l ...
... The electrical output will vary significantly with changes in the level of in-plane irradiance. Solar PV panel manufacturers quote the electrical output at standard test conditions (STC) with an irradiance level of 1000W/m2. Therefore, when commissioning a PV system, it is necessary to measure the l ...
MAX8784 Step-Up Regulator, Internal Charge Pumps, Switch General Description
... automatically increases the output voltages of the boost regulator and the positive charge-pump to stress test display panels during production. The MAX8784 can operate from input voltages of 4V to 5.5V and is optimized for LCD TV panel and LCD monitor applications. The step-up DC-DC regulator provi ...
... automatically increases the output voltages of the boost regulator and the positive charge-pump to stress test display panels during production. The MAX8784 can operate from input voltages of 4V to 5.5V and is optimized for LCD TV panel and LCD monitor applications. The step-up DC-DC regulator provi ...
ADM1073 数据手册DataSheet 下载
... capability for charging large capacitive loads Limited number of PWM cycles for FET SOA protection under short circuit condition Ability to configure device as continuous autoretry with a 5-second cooling period Shunt regulator topology to allow very large transient input supplies Separate UV and OV ...
... capability for charging large capacitive loads Limited number of PWM cycles for FET SOA protection under short circuit condition Ability to configure device as continuous autoretry with a 5-second cooling period Shunt regulator topology to allow very large transient input supplies Separate UV and OV ...
Sample Exam Solution
... If the core is completely demagnetized, then there is no residual flux, and Ea starts out at 0 and stays at 0. No voltage buildup will occur. 2. If the field resistance is too large, insufficient field current will flow to build the voltage up can also be a problem if the trapped flux is too small. ...
... If the core is completely demagnetized, then there is no residual flux, and Ea starts out at 0 and stays at 0. No voltage buildup will occur. 2. If the field resistance is too large, insufficient field current will flow to build the voltage up can also be a problem if the trapped flux is too small. ...
Inductors and transformers
... The relative permeability is very close to unity for all materials except for the ferromagnetic materials iron, cobalt, nickel, and a number of special alloys. For these materials, µr may range from 10 to 105 . The relative permeability is also a function of magnetic intensity in ferromagnetic mater ...
... The relative permeability is very close to unity for all materials except for the ferromagnetic materials iron, cobalt, nickel, and a number of special alloys. For these materials, µr may range from 10 to 105 . The relative permeability is also a function of magnetic intensity in ferromagnetic mater ...
AT10.1 Standard Sample Spec
... 2.1 - Battery charger shall automatically determine the appropriate DC output, in terms of either voltage or current required for maintaining the battery and load either by pre-programming or in-field re-programming, via the touch panel controls. 2.2 - The battery charger shall automatically know an ...
... 2.1 - Battery charger shall automatically determine the appropriate DC output, in terms of either voltage or current required for maintaining the battery and load either by pre-programming or in-field re-programming, via the touch panel controls. 2.2 - The battery charger shall automatically know an ...
dc1614a - LTC4012 High Current High Efficiency Multi
... 20V and is initially configured for a current limit of 10A. The charger float voltage is programmed by jumpers to support 1- to 4- series cells of both Li-Ion/Polymer and Li-iron phosphate (LiFePO4) at 4.2V/cell and 3.6V/cell, for a total of eight settings. The demo board is initially configured for ...
... 20V and is initially configured for a current limit of 10A. The charger float voltage is programmed by jumpers to support 1- to 4- series cells of both Li-Ion/Polymer and Li-iron phosphate (LiFePO4) at 4.2V/cell and 3.6V/cell, for a total of eight settings. The demo board is initially configured for ...
Methodology for relative location of voltage sag source using
... sags source. Fig. 1.a illustrates a one-line diagram of a radial distribution system. The network is parameterized by impedances between buses, voltage power quality monitors (PQMs) recording on the buses and finally a load. The analysis begins with the study of the behavior of the recorded voltages ...
... sags source. Fig. 1.a illustrates a one-line diagram of a radial distribution system. The network is parameterized by impedances between buses, voltage power quality monitors (PQMs) recording on the buses and finally a load. The analysis begins with the study of the behavior of the recorded voltages ...
WP1 INSTALLATION INSTRUCTIONS
... Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON ...
... Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON ...
Example: [Boylestad 10 th Ed. Eg 9.6
... Mesh vs Nodal Analysis • Mesh: Current source is an open circuit and it merges loops. • Nodal: Voltage source is a short circuit and it merges nodes. • Mesh: More popular as voltage sources do exist physically. • Nodal: Less popular as current sources do not exist physically except in models of ele ...
... Mesh vs Nodal Analysis • Mesh: Current source is an open circuit and it merges loops. • Nodal: Voltage source is a short circuit and it merges nodes. • Mesh: More popular as voltage sources do exist physically. • Nodal: Less popular as current sources do not exist physically except in models of ele ...
BD35395FJ-M
... be noted. To VTT_IN terminal, it is recommended to use a 10μF capacitor characterized with less change in capacitance. But it may depend on the characteristics of the power supply input and the impedance of the pc board wiring, which must be carefully checked before use. ・PGOOD PGOOD pin is power go ...
... be noted. To VTT_IN terminal, it is recommended to use a 10μF capacitor characterized with less change in capacitance. But it may depend on the characteristics of the power supply input and the impedance of the pc board wiring, which must be carefully checked before use. ・PGOOD PGOOD pin is power go ...
lab sheet - Faculty of Engineering
... Great care must be taken in designing an amplifier that could function properly in the megahertz range. The frequencies between 1MHz to 300MHz are collectively known as radio frequency (RF). Frequencies higher than 300MHz are categorized as microwave frequency (MF). An RF amplifier is an amplifier t ...
... Great care must be taken in designing an amplifier that could function properly in the megahertz range. The frequencies between 1MHz to 300MHz are collectively known as radio frequency (RF). Frequencies higher than 300MHz are categorized as microwave frequency (MF). An RF amplifier is an amplifier t ...
lab sheet - Faculty of Engineering
... Great care must be taken in designing an amplifier that could function properly in the megahertz range. The frequencies between 1MHz to 300MHz are collectively known as radio frequency (RF). Frequencies higher than 300MHz are categorized as microwave frequency (MF). An RF amplifier is an amplifier t ...
... Great care must be taken in designing an amplifier that could function properly in the megahertz range. The frequencies between 1MHz to 300MHz are collectively known as radio frequency (RF). Frequencies higher than 300MHz are categorized as microwave frequency (MF). An RF amplifier is an amplifier t ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.