MAX1177 16-Bit, 135ksps, Single-Supply ADC with 0 to 10V Input Range General Description
... The MAX1177 has an input scaler, which allows conversion of input voltages ranging from 0 to 10V, while operating from a single +5V analog supply. The input scaler attenuates and shifts the analog input to match the input range of the internal digital-to-analog converter (DAC). Figure 4 shows the eq ...
... The MAX1177 has an input scaler, which allows conversion of input voltages ranging from 0 to 10V, while operating from a single +5V analog supply. The input scaler attenuates and shifts the analog input to match the input range of the internal digital-to-analog converter (DAC). Figure 4 shows the eq ...
High-voltage reinforced isolation: Definitions
... isolation with silicon-dioxide (SiO2) as the dielectric. ...
... isolation with silicon-dioxide (SiO2) as the dielectric. ...
Lecture 5
... Operational Amplifers Op-amp is an electronic device that amplify the difference of voltage at its two inputs. ...
... Operational Amplifers Op-amp is an electronic device that amplify the difference of voltage at its two inputs. ...
International Journal of Energy and Power Engineering
... database in energy management systems. This paper presents an algorithm for state estimation of the Tanzanian power system network using a non-quadratic state criterion. Equality and inequality constraints existing in a power system are included in formulating the estimation problem. Equality constr ...
... database in energy management systems. This paper presents an algorithm for state estimation of the Tanzanian power system network using a non-quadratic state criterion. Equality and inequality constraints existing in a power system are included in formulating the estimation problem. Equality constr ...
Basic Low Power Digital Design - Compiler Microarchitecture Lab
... 2.2 Trends in Power Consumption At the macro-level, the most significant trend is the increasing contribution of leakage power in the total power dissipation of an electronic system designed in CMOS technology. For a long time, the switching component of the dynamic power was the major component of ...
... 2.2 Trends in Power Consumption At the macro-level, the most significant trend is the increasing contribution of leakage power in the total power dissipation of an electronic system designed in CMOS technology. For a long time, the switching component of the dynamic power was the major component of ...
CP4201612617
... seems likely to be possible as other researchers have described ways to use far lower VDD values to maintain logic state. ...
... seems likely to be possible as other researchers have described ways to use far lower VDD values to maintain logic state. ...
SWIFT Designer power supply design program
... complete the circuit (Figure 3). You may have different devices available than those in the default database; therefore, you will need to add them. To add a component to the database, click on the buttons in the schematic; for instance, “C1,” which will open the Input Capacitor selection form. (The ...
... complete the circuit (Figure 3). You may have different devices available than those in the default database; therefore, you will need to add them. To add a component to the database, click on the buttons in the schematic; for instance, “C1,” which will open the Input Capacitor selection form. (The ...
INMP405 - Shop the InvenSense Store
... The INMP405 output can be connected to a dedicated codec microphone input (see Figure 6) or to a high input impedance gain stage (see Figure 7.) A 0.1 µF ceramic capacitor placed close to the INMP405 supply pin is used for testing and is recommended to adequately decouple the microphone from noise o ...
... The INMP405 output can be connected to a dedicated codec microphone input (see Figure 6) or to a high input impedance gain stage (see Figure 7.) A 0.1 µF ceramic capacitor placed close to the INMP405 supply pin is used for testing and is recommended to adequately decouple the microphone from noise o ...
HART® Compatible Intelligent 2-wire In
... Shift Keying) communication method. The frequency signal is superimposed on the 4-20 mA signal as a near sinusshaped waveform. The average value of the superimposed signal is 0, and therefore, it will not interfere with the 4-20 mA signal. For a more detailed explanation of the HART concept, the rea ...
... Shift Keying) communication method. The frequency signal is superimposed on the 4-20 mA signal as a near sinusshaped waveform. The average value of the superimposed signal is 0, and therefore, it will not interfere with the 4-20 mA signal. For a more detailed explanation of the HART concept, the rea ...
Ch1 RLC Load - Bridging Theory into Practice
... • Physical object with the ability to store electric charge (i.e. “electric voltage”) • Consists of two – electrically isolated – metal electrodes, typically two conductive parallel plates • Is mostly used to store energy or for filtering purposes • The isolating material – the dielectric – defines ...
... • Physical object with the ability to store electric charge (i.e. “electric voltage”) • Consists of two – electrically isolated – metal electrodes, typically two conductive parallel plates • Is mostly used to store energy or for filtering purposes • The isolating material – the dielectric – defines ...
Optical Sensors
... Association (IrDA) standards are normally used for these signals. For optical communication, a modulated IR light beam transmitted by an emitter LED is received by a silicon photodiode/ transistor. Since IR does not penetrate walls, it does not interfere with other signals in indoor environments. Th ...
... Association (IrDA) standards are normally used for these signals. For optical communication, a modulated IR light beam transmitted by an emitter LED is received by a silicon photodiode/ transistor. Since IR does not penetrate walls, it does not interfere with other signals in indoor environments. Th ...
I2C System Monitor Combines Temperature, Voltage and Current
... measured and stored for reference, after which the heater is switched on, and given a few seconds to heat the surroundings. The temperature is again measured and compared with the first temperature. If the temperature difference is greater than a preset threshold, the sensor is determined to be abov ...
... measured and stored for reference, after which the heater is switched on, and given a few seconds to heat the surroundings. The temperature is again measured and compared with the first temperature. If the temperature difference is greater than a preset threshold, the sensor is determined to be abov ...
S2000C
... 10 feet at the alarm HORN SETTING shall be 101 dBA minimum for MT and 99 dBA minimum for MT Strobes, at nominal voltage. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse po ...
... 10 feet at the alarm HORN SETTING shall be 101 dBA minimum for MT and 99 dBA minimum for MT Strobes, at nominal voltage. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse po ...
Motivation to update guidance on electrical systems
... side of the transformer • The measurement of one or more of the following parameters – Negative sequence voltage – Negative sequence current – Magnetization current – Zero sequence current – Zero sequence voltage – Current injection – Phase to phase or phase to earth voltage properly set for unbalan ...
... side of the transformer • The measurement of one or more of the following parameters – Negative sequence voltage – Negative sequence current – Magnetization current – Zero sequence current – Zero sequence voltage – Current injection – Phase to phase or phase to earth voltage properly set for unbalan ...
High Voltage Direct Current Transmission –
... only possible solution. • A digital control system provides accurate and fast control of the active power flow. • Fast modulation of DC transmission power can be used to damp power oscillations in an AC grid and thus improve the system stability. ...
... only possible solution. • A digital control system provides accurate and fast control of the active power flow. • Fast modulation of DC transmission power can be used to damp power oscillations in an AC grid and thus improve the system stability. ...
Capacitor unbalance protection for blocks in double
... element that the fuse is designed to isolate if the element becomes faulty. After the breakdown of an element, the fuse connected to it will blow and isolate it from the remaining part of the capacitor, which allows the unit to continue in service. The blowing of one or more fuses decreases the capa ...
... element that the fuse is designed to isolate if the element becomes faulty. After the breakdown of an element, the fuse connected to it will blow and isolate it from the remaining part of the capacitor, which allows the unit to continue in service. The blowing of one or more fuses decreases the capa ...
SP503 数据资料DataSheet下载
... Of course this method will not allow programmability to the serial port if the user wants to run various protocols to that port. To actively switch protocols by software control, you can use analog switches or relays. Sipex recommends using low-ON resistance analog switches, such as Siliconix DG643© ...
... Of course this method will not allow programmability to the serial port if the user wants to run various protocols to that port. To actively switch protocols by software control, you can use analog switches or relays. Sipex recommends using low-ON resistance analog switches, such as Siliconix DG643© ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.