Form Factors Power Supplies and Working Inside the Computer
... Figure 4-32 Post Code Master diagnostic card by Microsystems Developments, Inc. Courtesy: Course Technology/Cengage Learning A+ Guide to Managing and Maintaining your PC, 7e ...
... Figure 4-32 Post Code Master diagnostic card by Microsystems Developments, Inc. Courtesy: Course Technology/Cengage Learning A+ Guide to Managing and Maintaining your PC, 7e ...
AN1957
... Another major function is Low Voltage Detect (LVD), which detects power supply brownouts and glitches. Whenever VCC falls below the Reset threshold (VRST), the Reset output is asserted and remains so trec after VCC increases above the Vrst threshold. In the case of an RC circuit, no minimum Reset pu ...
... Another major function is Low Voltage Detect (LVD), which detects power supply brownouts and glitches. Whenever VCC falls below the Reset threshold (VRST), the Reset output is asserted and remains so trec after VCC increases above the Vrst threshold. In the case of an RC circuit, no minimum Reset pu ...
MX7839 Octal, 13-Bit Voltage-Output DAC with Parallel Interface General Description
... precision amplifiers. This allows the flexibility of using resistive dividers to set the reference voltages. Because of the relatively high multiplying bandwidth of the reference input (188kHz), any signal present on the reference pin within this bandwidth is replicated on the DAC output. The DUTGND ...
... precision amplifiers. This allows the flexibility of using resistive dividers to set the reference voltages. Because of the relatively high multiplying bandwidth of the reference input (188kHz), any signal present on the reference pin within this bandwidth is replicated on the DAC output. The DUTGND ...
• Set-Top-Box Conditional Access and Pay-per-View
... 73S8010R is a cost-effective solution for any application where a 5 V (typically -5% +10%) power supply is available. Hardware support for auxiliary I/O lines, C4 / C8 contacts is provided. Emergency card deactivation is initiated upon card extraction or upon any fault generated by the protection ci ...
... 73S8010R is a cost-effective solution for any application where a 5 V (typically -5% +10%) power supply is available. Hardware support for auxiliary I/O lines, C4 / C8 contacts is provided. Emergency card deactivation is initiated upon card extraction or upon any fault generated by the protection ci ...
ADG3243 数据手册DataSheet 下载
... maximum output signal will, as before, be clamped to within a voltage threshold below the VCC supply. In this case, the output will be limited to approximately 1.8 V, as shown in Figure 8. ...
... maximum output signal will, as before, be clamped to within a voltage threshold below the VCC supply. In this case, the output will be limited to approximately 1.8 V, as shown in Figure 8. ...
General Description Features
... along with RCD components R3, C4, D3, and blockingdiode D4. Perform a power-on or reset the IC using pushbutton switch SW1 to affect the changes. For DC-disconnect operation, shut down the internal oscillator by installing a shunt on jumper JU6. Then remove resistor R3 and install a 0I 0402 surfacem ...
... along with RCD components R3, C4, D3, and blockingdiode D4. Perform a power-on or reset the IC using pushbutton switch SW1 to affect the changes. For DC-disconnect operation, shut down the internal oscillator by installing a shunt on jumper JU6. Then remove resistor R3 and install a 0I 0402 surfacem ...
CGR-0118Z DUAL CATV 5MHz to 65MHz CATV AMP IC Features Product Description
... Exposed area on the bottom side of the package must be soldered to the ground plane of hte board for optimum thermal and RF performance. Several vias should be located under the EPAD as shown in the recommended land pattern. ...
... Exposed area on the bottom side of the package must be soldered to the ground plane of hte board for optimum thermal and RF performance. Several vias should be located under the EPAD as shown in the recommended land pattern. ...
Low Voltage Current Mode Push-Pull PWM
... A 200-kHz push-pull application circuit with a full-wave rectifier is shown in Figure 2. The output, VO, provides 5 V at 50 W maximum and is electrically isolated from the input. Since the UCC3808A is a peak-current-mode controller the 2N2907 emitter following amplifier (buffers the CT waveform) pro ...
... A 200-kHz push-pull application circuit with a full-wave rectifier is shown in Figure 2. The output, VO, provides 5 V at 50 W maximum and is electrically isolated from the input. Since the UCC3808A is a peak-current-mode controller the 2N2907 emitter following amplifier (buffers the CT waveform) pro ...
Repair Tips for Bearcat Scanners
... flows in the primary as long as the AC line cord is plugged into an active AC outlet. These transformers contain an internal circuit breaker, not visible without unwinding (destroying) the transformer. The internal breaker is known to fail prematurely in a batch of Bearcat power transformers. If you ...
... flows in the primary as long as the AC line cord is plugged into an active AC outlet. These transformers contain an internal circuit breaker, not visible without unwinding (destroying) the transformer. The internal breaker is known to fail prematurely in a batch of Bearcat power transformers. If you ...
MAX15112 Evaluation Kit Evaluates: MAX15112 General Description Features
... evaluate the MAX15112 high-efficiency, 12A, step-down regulator with integrated switches. The applications include distributed power systems, portable devices, and preregulators. The EV kit is preset for 1.5V output at load currents up to 12A from a 2.7V to 5.5V input supply. The device features a 1 ...
... evaluate the MAX15112 high-efficiency, 12A, step-down regulator with integrated switches. The applications include distributed power systems, portable devices, and preregulators. The EV kit is preset for 1.5V output at load currents up to 12A from a 2.7V to 5.5V input supply. The device features a 1 ...
ADP3629 数据手册DataSheet 下载
... the pin externally for the drivers to operate normally. In some power systems, it is sometimes necessary to provide an additional overvoltage protection (OVP) or overcurrent protection (OCP) shutdown signal to turn off the power devices (MOSFETs or IGBTs) in case of failure of the main controller. A ...
... the pin externally for the drivers to operate normally. In some power systems, it is sometimes necessary to provide an additional overvoltage protection (OVP) or overcurrent protection (OCP) shutdown signal to turn off the power devices (MOSFETs or IGBTs) in case of failure of the main controller. A ...
Function Of Starter
... The operating coil CM get energized by following path: ‘ L1 – PB2 – PB1 – CM – OL – OL – OL – L2’ At the same time, the operating coil Cs get energized by following path : ‘ L1 – PB2 – PB1 – TO –D –CS – OL – OL – OL – L2’ The operating coil CD is energized by following path 'L1 - PB2 –MA – TC – S – ...
... The operating coil CM get energized by following path: ‘ L1 – PB2 – PB1 – CM – OL – OL – OL – L2’ At the same time, the operating coil Cs get energized by following path : ‘ L1 – PB2 – PB1 – TO –D –CS – OL – OL – OL – L2’ The operating coil CD is energized by following path 'L1 - PB2 –MA – TC – S – ...
Linear Actuator Controls
... Some versions of the DCG actuator control series can operate two actuators in parallel synchronous motion. To be able to use this feature the actuators must be equipped with feedback encoders. This function is useful when it is necessary to move two actuators to the same position with the same speed ...
... Some versions of the DCG actuator control series can operate two actuators in parallel synchronous motion. To be able to use this feature the actuators must be equipped with feedback encoders. This function is useful when it is necessary to move two actuators to the same position with the same speed ...
DDA-3000 - Biddle Megger
... The Acquisition Control MENU allows the user to select between two different current measurement methods. By pressing the softkey directly beneath either PEAK or RMS, the user selects which calculation will be used in displaying measured current on the metering display. PEAK measures the highest pe ...
... The Acquisition Control MENU allows the user to select between two different current measurement methods. By pressing the softkey directly beneath either PEAK or RMS, the user selects which calculation will be used in displaying measured current on the metering display. PEAK measures the highest pe ...
ics85104i.pdf
... Pd_total = Total Device Power Dissipation (example calculation is in Section 1 above) TA = Ambient Temperature In order to calculate junction temperature, the appropriate junction-to-ambient thermal resistance θJA must be used. Assuming no air flow and a multi-layer board, the appropriate value is 9 ...
... Pd_total = Total Device Power Dissipation (example calculation is in Section 1 above) TA = Ambient Temperature In order to calculate junction temperature, the appropriate junction-to-ambient thermal resistance θJA must be used. Assuming no air flow and a multi-layer board, the appropriate value is 9 ...
SIGC186T170R3E
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. The Infineon Technologies component described in this Data Sheet may be used in life-support devices or systems and/or automo ...
AVS2000 PRO
... Thank you for purchasing the Monster Power Professional Reference Automatic Voltage Stabilizer™AVS 2000 PRO. The AVS 2000 PRO is designed to stabilize power line fluctuations and maintain constant voltage to your professional components. Voltage sags (below the standard RMS value of 120 volts) are o ...
... Thank you for purchasing the Monster Power Professional Reference Automatic Voltage Stabilizer™AVS 2000 PRO. The AVS 2000 PRO is designed to stabilize power line fluctuations and maintain constant voltage to your professional components. Voltage sags (below the standard RMS value of 120 volts) are o ...
a CMOS, 125 MHz Complete DDS Synthesizer AD9850
... 11.25°, and any combination thereof. The AD9850 also contains a high speed comparator that can be configured to accept the (externally) filtered output of the DAC to generate a low jitter square wave output. This facilitates the device’s use as an agile clock generator function. The frequency tuning ...
... 11.25°, and any combination thereof. The AD9850 also contains a high speed comparator that can be configured to accept the (externally) filtered output of the DAC to generate a low jitter square wave output. This facilitates the device’s use as an agile clock generator function. The frequency tuning ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.