• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Institutionen för systemteknik
Institutionen för systemteknik

... measure approximately 18 meters. This results in long wires between the alternator placed at the engine and the batteries placed in the front of the bus. Together with large power consuming units in the bus, such as air condition units and fans this will result in voltage drops in the charging circu ...
DIGITAL INPUTS – TERMINAL MODE (P
DIGITAL INPUTS – TERMINAL MODE (P

... Either V = kf (linear) or V = kf 2 (pumps / fans with HVAC rating). Note when P-06 is set to 1 the ramps are automatically set to 60 s. Deceleration ramp time after mains loss (P-05 = 0 or 2) or when fast stop activated (see P-19). When P-05 = 2 and P-07 = 0, activating the fast stop disables the dr ...
In-System Programming (ISP)
In-System Programming (ISP)

... decoupling capacitors of 0.1 µF. ...
1 - Cooper Industries
1 - Cooper Industries

... Note: The transformer must be specified with the High Voltage Flange in order to provide the primary air disconnect switch. [ ] The transformer primary shall be non-fused. It shall include a copper bus transition to the transformer. Note: Required when full load current exceeds ...
1004 eDIN Demultiplexer Spec
1004 eDIN Demultiplexer Spec

... Each analog output shall be rated for a maximum 16 volts DC and maximum current of 10 mA (sourcing) or 30 mA (current sinking). The Module shall be equipped with a blocking diode for each output to prevent accidental damage to the module when used in current sinking applications. It shall be possibl ...
Aluminum Electrolytic Capacitors Conductive Polymer
Aluminum Electrolytic Capacitors Conductive Polymer

Chapter 4 Specifying Simulation Output
Chapter 4 Specifying Simulation Output

... .PRINT DISTO HD2(M) HD2(DB) Prints the magnitude and decibel values of the second harmonic distortion component through the load resistor specified in the .DISTO statement (not shown). .PLOT NOISE INOISE ONOISE Note: The noise and distortion output variable may be specified along with other AC outpu ...
Aalborg Universitet Single-Phase Microgrid with Seamless Transition Capabilities between Modes of Operation
Aalborg Universitet Single-Phase Microgrid with Seamless Transition Capabilities between Modes of Operation

PLC Trainer PLCE www.edibon.com Technical Teaching Equipment
PLC Trainer PLCE www.edibon.com Technical Teaching Equipment

... PLCE-SALL. Automatic Filling System It represents an automatic filling system where we can choose the number of elements packed in each pack. We can emulate the motors and the presence sensor of the system ...
700` 54` 24 54 36 70”
700` 54` 24 54 36 70”

Next D 45Amp ESC manual
Next D 45Amp ESC manual

... * 2°, 8° – Setting for most of in-runner motors. * 15°, 22° –Setting for motors with 6 or more poles. * 30° – Setting for motors with more poles. In most cases, automatic timing works well for all types of motors. However for high efficiency we recommend the Low timing setting for 2 pole motors (gen ...
NX Series Analog Output Units Datasheet
NX Series Analog Output Units Datasheet

... Analog Outputs to meet all machine control needs; from general-purpose outputs to highspeed synchronous, highresolution control outputs • Analog Output Units for the NX-series modular I/O system. • Connect to other NX-series I/O Units and EtherCAT Coupler units using the high-speed NX-bus. • Separat ...
Switched Mode Converters (1 Quadrant)
Switched Mode Converters (1 Quadrant)

Generation of closed magnetic flux surfaces in a large spherical
Generation of closed magnetic flux surfaces in a large spherical

COMPUTER AIDED DESIGN OF ELECTRONIC DEVICES
COMPUTER AIDED DESIGN OF ELECTRONIC DEVICES

... What is CAD? Computer-aided design (CAD) is the use of computer systems to assist in the creation, modification, analysis, or optimization of a design. CAD software is used to increase the productivity of the designer, improve the quality of design, improve communications through documentation, and ...
Technical manual
Technical manual

... will consume more water than a battery on standby operation. In theory, the quantity of water used can be found by the Faradic equation that each ampere-hour of overcharge breaks down 0.366 cm3 of water. However, in practice, the water usage will be less than this as the overcharge current is also n ...
XADC Layout Guidelines
XADC Layout Guidelines

... 5 mil (127 micron) traces were placed at a spacing of 6 mils (150 microns) wherever possible. This helps ensure that any interference, specifically EMI, that is picked up on one line is also picked up on the other line with the same magnitude and phase. The loop area is also reduced, which should he ...
Experiment 4 - Portal UniMAP
Experiment 4 - Portal UniMAP

... Laboratory Module ...
TPS65011EVM-049 数据资料 dataSheet 下载
TPS65011EVM-049 数据资料 dataSheet 下载

... and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyr ...
Resistors - Bieap.gov.in
Resistors - Bieap.gov.in

... potentiometers are used. These have wire wound elements in place of carbon strips are available in 1,2,3 and 4 volts wire-wound potentiometer is shown in When continuous variation of the resistance is not required, a tapped resistance is used. Fixed taps are provided at a number of points an a wirew ...
Ω MAX4741/MAX4742/MAX4743 0.8 , Low-Voltage, Single-Supply Dual SPST
Ω MAX4741/MAX4742/MAX4743 0.8 , Low-Voltage, Single-Supply Dual SPST

... switches that operate from a single +1.6V to +3.6V supply. These devices have fast switching speeds (tON = 24ns, tOFF = 16ns max), handle rail-to-rail analog signals, and consume less than 1µW of quiescent power. The MAX4743 has break-before-make switching. When powered from a +3V supply, the MAX474 ...
Chapter 11 Shielded Metal Arc Welding Principles
Chapter 11 Shielded Metal Arc Welding Principles

TLV431x Low-Voltage Adjustable Precision
TLV431x Low-Voltage Adjustable Precision

... stability over applicable industrial and commercial temperature ranges. Output voltage can be set to any value between VREF (1.24 V) and 6 V with two external resistors (see Figure 20). These devices operate from a lower voltage (1.24 V) than the widely used TL431 and TL1431 shunt-regulator referenc ...
ADVANCED INVERTER CONTROL FOR UNINTERRUPTIBLE
ADVANCED INVERTER CONTROL FOR UNINTERRUPTIBLE

... Uninterruptible power supply (UPS) is a typical example of voltage regulated inverter applications. It is widely used to supply high quality, continuous and disturbance-free AC power to critical loads such as medical equipments, computers and communication systems. A good UPS system requires not onl ...
How High-Efficiency Alternators Save Fuel
How High-Efficiency Alternators Save Fuel

< 1 ... 173 174 175 176 177 178 179 180 181 ... 1376 >

Rectifier



A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report