
Reducing the output filter of a Class-D amplifier
... Class-D with half filter Class-D with a half filter had a lower quiescent current and performed as good as or better than the Class-D with full filter in THD+N and IMD. The quiescent current lowers as the inductor of the half filter increases. As inductance increases, peaking occurs at the corner fr ...
... Class-D with half filter Class-D with a half filter had a lower quiescent current and performed as good as or better than the Class-D with full filter in THD+N and IMD. The quiescent current lowers as the inductor of the half filter increases. As inductance increases, peaking occurs at the corner fr ...
T.C. Neugebauer and D.J. Perreault, “Parasitic Capacitance Cancellation in Filter Inductors,” IEEE Transactions on Power Electronics , Vol. 21, No. 1, January 2006, pp. 282-288.
... ILTER inductors and common-mode chokes suffer from both parasitic resistance and capacitance. Winding resistance and core loss lead to parasitic resistance, while parasitic capacitance arises from capacitance between winding turns and from winding-to-core capacitance. The distributed parasitic compo ...
... ILTER inductors and common-mode chokes suffer from both parasitic resistance and capacitance. Winding resistance and core loss lead to parasitic resistance, while parasitic capacitance arises from capacitance between winding turns and from winding-to-core capacitance. The distributed parasitic compo ...
Selecting E7/P7/F7 Drives for Single-Phase Input
... Single-phase 60Hz input results in 120Hz DC bus ripple! – DC bus capacitors need to provide more power – DC bus level will decrease a larger amount than with threephase input during this time ...
... Single-phase 60Hz input results in 120Hz DC bus ripple! – DC bus capacitors need to provide more power – DC bus level will decrease a larger amount than with threephase input during this time ...
LAPPEENRANTA UNIVERSITY OF TECHNOLOGY DEPARTMENT
... a back-up system or as a part of the utility system. The purpose of the back-up microgrid system is to feed local loads when the main grid fails for any reason. This mode is also called the emergency mode. The configuration of a microgrid in the grid-connected mode also requires a power source and a ...
... a back-up system or as a part of the utility system. The purpose of the back-up microgrid system is to feed local loads when the main grid fails for any reason. This mode is also called the emergency mode. The configuration of a microgrid in the grid-connected mode also requires a power source and a ...
Train Current Detection Manual_J2C
... It can withstands 8 amps of continues track power and 200 amps of surge. So if a fault occurs on the track, the breaker in the power supply will trip first and not damage the detection circuit. The J2C detection circuit uses an advanced diode sensing circuit, while some other detection circuits use ...
... It can withstands 8 amps of continues track power and 200 amps of surge. So if a fault occurs on the track, the breaker in the power supply will trip first and not damage the detection circuit. The J2C detection circuit uses an advanced diode sensing circuit, while some other detection circuits use ...
TJF1052i CAN 1. General description
... The TJF1052i is a high-speed CAN transceiver that provides a galvanically isolated interface between a Controller Area Network (CAN) protocol controller and the physical two-wire CAN bus. The TJF1052i is specifically targeted at industrial applications, where galvanic isolation barriers are needed b ...
... The TJF1052i is a high-speed CAN transceiver that provides a galvanically isolated interface between a Controller Area Network (CAN) protocol controller and the physical two-wire CAN bus. The TJF1052i is specifically targeted at industrial applications, where galvanic isolation barriers are needed b ...
S7-I/O Input/Output Device
... The S7-I/O device is designed for use with WinPM™, Siemens’ Microsoft Windows™-based power monitoring and control software. The device communicates with a supervisory computer running WinPM by way of the SEAbus communications protocol. ...
... The S7-I/O device is designed for use with WinPM™, Siemens’ Microsoft Windows™-based power monitoring and control software. The device communicates with a supervisory computer running WinPM by way of the SEAbus communications protocol. ...
AN4704, 3-phase Sensorless BLDC Motor Control Kit with the S12
... motor, while the motor torque/speed only depends on the amplitude of the quasi-square current waveform. Continued control of the amplitude of the quasi-square current waveform for each phase of the motor is ensured by hysteresis or PWM control. PWM control is commonly used in applications where micr ...
... motor, while the motor torque/speed only depends on the amplitude of the quasi-square current waveform. Continued control of the amplitude of the quasi-square current waveform for each phase of the motor is ensured by hysteresis or PWM control. PWM control is commonly used in applications where micr ...
Increased transformer reliability through transparent
... and reliable determination of the actual bushing condition. For identifying changes in the bushing’s condition, bushing power factor and capacitance values are commonly calculated by using the sum-of- three-currents and adjacent-phase analysis methods. These analysis methods provide stable imbalance ...
... and reliable determination of the actual bushing condition. For identifying changes in the bushing’s condition, bushing power factor and capacitance values are commonly calculated by using the sum-of- three-currents and adjacent-phase analysis methods. These analysis methods provide stable imbalance ...
Applications of the CA3080 High-Performance
... The amplifier's output-current is proportional to the voltage difference at its differential input terminals. This Application Note describes the operation of the OTA and features various circuits using the OTA. For example, communications and industrial applications including modulators, multiplexe ...
... The amplifier's output-current is proportional to the voltage difference at its differential input terminals. This Application Note describes the operation of the OTA and features various circuits using the OTA. For example, communications and industrial applications including modulators, multiplexe ...
Cashpower GEM Lite
... retrofitting of existing bottom connected electromechanical or electronic watt-hour meters. The meter is easy to install and boasts an easy to read, language independent Liquid Crystal Display (LCD) and a wide range of information registers which can be easily accessed by pressing the information bu ...
... retrofitting of existing bottom connected electromechanical or electronic watt-hour meters. The meter is easy to install and boasts an easy to read, language independent Liquid Crystal Display (LCD) and a wide range of information registers which can be easily accessed by pressing the information bu ...
CA235001EN
... Advantages are particularly evident in areas subjected to extremely heavy lightning surges and/or where soil conditions result in high ground resistance values. Without interconnection, surge voltage may build up high enough to puncture the transformer insulation. Interconnection limits the potentia ...
... Advantages are particularly evident in areas subjected to extremely heavy lightning surges and/or where soil conditions result in high ground resistance values. Without interconnection, surge voltage may build up high enough to puncture the transformer insulation. Interconnection limits the potentia ...
How to Coordinate Transformer Primary-Side Fuses with Feeder Reclosers Using Coordinaide
... Automatic circuit reclosers sense overcurrents, interrupt them, and then automatically reclose to reenergize the feeder. Most faults on overhead distribution systems—perhaps as many as 75 to 80%—are temporary in nature, lasting only a few cycles to a few seconds. With their “trip and reclose” capabi ...
... Automatic circuit reclosers sense overcurrents, interrupt them, and then automatically reclose to reenergize the feeder. Most faults on overhead distribution systems—perhaps as many as 75 to 80%—are temporary in nature, lasting only a few cycles to a few seconds. With their “trip and reclose” capabi ...
An Extended Doherty Amplifier With High Efficiency , Student Member, IEEE
... The output power range between the two peaks in power-added efficiency (PAE) (as seen in Fig. 2) of 9 dB is achieved with a careful design of the input and output matching networks. In Section II, the basic principle of operation and a derivation of the design equations are presented. The analysis a ...
... The output power range between the two peaks in power-added efficiency (PAE) (as seen in Fig. 2) of 9 dB is achieved with a careful design of the input and output matching networks. In Section II, the basic principle of operation and a derivation of the design equations are presented. The analysis a ...
M48T08
... oscillator of the M48T08/18/08Y are integrated on one silicon chip. The two circuits are interconnected at the upper eight memory locations to provide user accessible BYTEWIDE™ clock information in the bytes with addresses 1FF8h-1FFFh. The clock locations contain the year, month, date, day, hour, mi ...
... oscillator of the M48T08/18/08Y are integrated on one silicon chip. The two circuits are interconnected at the upper eight memory locations to provide user accessible BYTEWIDE™ clock information in the bytes with addresses 1FF8h-1FFFh. The clock locations contain the year, month, date, day, hour, mi ...
Built-In System Protection for Industrial Drives
... TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI ...
... TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI ...
M750 Display Unit
... complying with the requirements for Safety Extra Low Voltage (SELV) circuits. Sensor connections - All sensor connections are made via the five way 'fast wiring' socket at the rear of the unit (wire size 0.5 mm² (0.02"²) to 1.5 mm² (0.06"²)). Note: Screened cable is recommended for thermocouple, RTD ...
... complying with the requirements for Safety Extra Low Voltage (SELV) circuits. Sensor connections - All sensor connections are made via the five way 'fast wiring' socket at the rear of the unit (wire size 0.5 mm² (0.02"²) to 1.5 mm² (0.06"²)). Note: Screened cable is recommended for thermocouple, RTD ...
COMPANY - Vishay
... route, switch, and block radio frequency (RF) signals. Vishay Intertechnology diodes include all types of rectifiers; small-signal switching, Zener and PIN diodes; and products for transient voltage suppression (TVS), electrostatic discharge (ESD) protection, and electromagnetic interference (EMI) f ...
... route, switch, and block radio frequency (RF) signals. Vishay Intertechnology diodes include all types of rectifiers; small-signal switching, Zener and PIN diodes; and products for transient voltage suppression (TVS), electrostatic discharge (ESD) protection, and electromagnetic interference (EMI) f ...
Implementation of 12-bit delta-sigma DACwith
... Comparing ∆Σ DAC with PWM DAC To compare the performance of the ∆Σ DAC, a PWM DAC was implemented with software and the microcontroller on the same MSC12xx board. In the implementation, a counter was used to count from 0 to 2N–1, and the count value was compared with the DAC input after each increme ...
... Comparing ∆Σ DAC with PWM DAC To compare the performance of the ∆Σ DAC, a PWM DAC was implemented with software and the microcontroller on the same MSC12xx board. In the implementation, a counter was used to count from 0 to 2N–1, and the count value was compared with the DAC input after each increme ...
Rectifier

A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.