TT2140LS
... semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety meas ...
... semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety meas ...
Action Pak AP4300 Data Sheet
... The isolated duty-cycle is then converted back to a DC level proportional to the input. The DC signal is then buffered by an output stage which allows zero and span adjustments. In units having a current output (e.g. 4-20mA) the output is a constant current source, controlled by the output buffer st ...
... The isolated duty-cycle is then converted back to a DC level proportional to the input. The DC signal is then buffered by an output stage which allows zero and span adjustments. In units having a current output (e.g. 4-20mA) the output is a constant current source, controlled by the output buffer st ...
Tariff Rule No. 2 Character of Servic
... c. Three Phase Service at 480 Volts or 2400 Volts Customers with an aggregate connected load of 100 KVA or more or a motor rated 50 HP or more may be served at 3-wire 480 volts or 4-wire 480Y/277 volts. Customers with an aggregate connected load of 500 KVA or more or a motor rated 250 HP or more may ...
... c. Three Phase Service at 480 Volts or 2400 Volts Customers with an aggregate connected load of 100 KVA or more or a motor rated 50 HP or more may be served at 3-wire 480 volts or 4-wire 480Y/277 volts. Customers with an aggregate connected load of 500 KVA or more or a motor rated 250 HP or more may ...
Data Sheet - Asahi Kasei Microdevices
... These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not implied. Exposure to absolute-maximum-rating conditions for extended periods may affect device reliability. Electrical parameters ...
... These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not implied. Exposure to absolute-maximum-rating conditions for extended periods may affect device reliability. Electrical parameters ...
FM SOLID STATE TRANSMITER PFS 30000/KS
... °The PFS 30000/K transmitter is designed to operate on 87.5 - 108 MHz frequency range for FM radio broadcasting appliances with RF output power. The PFS 30000/K is composed of: -PFS 2000/K, 2000 W FM Exciter and Driver Amplifier; -KFS 30000, 30kW FM Power Amplifier ° COLD-FET™ technology. This revol ...
... °The PFS 30000/K transmitter is designed to operate on 87.5 - 108 MHz frequency range for FM radio broadcasting appliances with RF output power. The PFS 30000/K is composed of: -PFS 2000/K, 2000 W FM Exciter and Driver Amplifier; -KFS 30000, 30kW FM Power Amplifier ° COLD-FET™ technology. This revol ...
Physics 09-06 Electromotive Force
... 11. An automobile starter motor has an equivalent resistance of 0.0500 Ω and is supplied by a 12.0-V battery with a 0.0100-Ω internal resistance. (a) What is the current to the motor? (b) What voltage is applied to it? (c) What power is supplied to the motor? (d) Repeat these calculations for when t ...
... 11. An automobile starter motor has an equivalent resistance of 0.0500 Ω and is supplied by a 12.0-V battery with a 0.0100-Ω internal resistance. (a) What is the current to the motor? (b) What voltage is applied to it? (c) What power is supplied to the motor? (d) Repeat these calculations for when t ...
BJ23360364
... systems. This configuration solves a typical problem found in remote (or rural) applications in which only the single-phase grid is available to supply a three-phase load. Detection and compensation are very important to control an active filter. Detection and compensation are very important to cont ...
... systems. This configuration solves a typical problem found in remote (or rural) applications in which only the single-phase grid is available to supply a three-phase load. Detection and compensation are very important to control an active filter. Detection and compensation are very important to cont ...
UMZ-T2-1042-A16-G 数据资料DataSheet下载
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
AN-6075 Compact Green-Mode Adapter Using FSQ500L for Low Cost 1. Introduction www.fairchildsemi.com
... 4. Printed Circuit Board Layout High-frequency switching current / voltage makes printed circuit board layout a very important design issue. Good PCB layout minimizes excessive EMI helps the power supply survive during surge/ESD tests. ...
... 4. Printed Circuit Board Layout High-frequency switching current / voltage makes printed circuit board layout a very important design issue. Good PCB layout minimizes excessive EMI helps the power supply survive during surge/ESD tests. ...
display
... MUST be located behind rider, be operated if machine is on its side, be a red button with a yellow disc of at least 8cm in diameter reading "Emergency" in red or black letters, latch down mechanically once it has been operated, require manual operation to reset it, act as a General Circuit Breaker t ...
... MUST be located behind rider, be operated if machine is on its side, be a red button with a yellow disc of at least 8cm in diameter reading "Emergency" in red or black letters, latch down mechanically once it has been operated, require manual operation to reset it, act as a General Circuit Breaker t ...
Unit-8Lecture 52 TESTING OF CABLES Cables are very important
... Neutral current method : In the neutral current method, a record of the impulse current flowing through a resistive shunt between the neutral and ground point is used for detecting the fault. The neutral current oscillogram consists of a high frequency oscillation, a low frequency disturbance, and a ...
... Neutral current method : In the neutral current method, a record of the impulse current flowing through a resistive shunt between the neutral and ground point is used for detecting the fault. The neutral current oscillogram consists of a high frequency oscillation, a low frequency disturbance, and a ...
Induction - Palang Thai
... DC Alternator (automotive) • May be rewound for lower rpm at low head. • The field may need a battery boost to start. • Use high voltage ac output with a step-down transformer and rectifier for long transmission distance. ...
... DC Alternator (automotive) • May be rewound for lower rpm at low head. • The field may need a battery boost to start. • Use high voltage ac output with a step-down transformer and rectifier for long transmission distance. ...
L6374
... The input stage of each channel is a high im-pedence comparator with built-in hysteresis (200 mV) for high noise immunity. Each comparator has one input connected to all the others and tied to a common pin Ref (Pin 11). If this pin is left floating an internal precise band gap voltage reference (1.2 ...
... The input stage of each channel is a high im-pedence comparator with built-in hysteresis (200 mV) for high noise immunity. Each comparator has one input connected to all the others and tied to a common pin Ref (Pin 11). If this pin is left floating an internal precise band gap voltage reference (1.2 ...
COMBOLIGHT Remodel Recessed Trimless - 12V AR70 - 1 Light
... beveled “knife-edge” lips to ensure a clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction ...
... beveled “knife-edge” lips to ensure a clean edge. Can accommodate various ceiling thickness. B.... System Protection: Thermal protection provided to guard against overheating and misuse of insulation over and around fixture. Vent holes in housing provide cooler operation. C.... Junction Box Junction ...
View Detail
... 4. What are the advantages of single phase bridge converter over single phase midpoint converter? a. SCRs are subjected to a peak-inverse voltage of 2Vm in a fully controlled bridge rectifier. Hence for same voltage and current ratings of SCrs, power handled by mid-point configuration is about b. In ...
... 4. What are the advantages of single phase bridge converter over single phase midpoint converter? a. SCRs are subjected to a peak-inverse voltage of 2Vm in a fully controlled bridge rectifier. Hence for same voltage and current ratings of SCrs, power handled by mid-point configuration is about b. In ...
Universal Telephone Hold
... connected to the hold components through bridge rectifier BR so the input is not polarity sensitive and the input lines may be connected either way. BR always connects the positive side of the line to zener diode D2 and the negative side of the line to IC2. If L1 is positive, current flows into the ...
... connected to the hold components through bridge rectifier BR so the input is not polarity sensitive and the input lines may be connected either way. BR always connects the positive side of the line to zener diode D2 and the negative side of the line to IC2. If L1 is positive, current flows into the ...
DN207 - LTC2400 High Accuracy Differential to Single-Ended Converter for ±5V Supplies
... currents introducing an error source into CH, an optional guard circuit could be added as shown. The common point of these two resistors produces the potential for the guard ring. Consult the LTC1043 data sheet for more information. As is good practice in all high precision circuits, keep all lead ...
... currents introducing an error source into CH, an optional guard circuit could be added as shown. The common point of these two resistors produces the potential for the guard ring. Consult the LTC1043 data sheet for more information. As is good practice in all high precision circuits, keep all lead ...
AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter ISO9001 Certified
... system where monitoring and analyzing will help protecting the investment on sensitive equipments. AcuRev 2000 series meters provides power quality parameters such as voltage and current THD, individual voltage and current harmonics up to 31st order, voltage crest factor, current K factor, voltage a ...
... system where monitoring and analyzing will help protecting the investment on sensitive equipments. AcuRev 2000 series meters provides power quality parameters such as voltage and current THD, individual voltage and current harmonics up to 31st order, voltage crest factor, current K factor, voltage a ...
FST3253 Dual 4:1 Multiplexer/Demultiplexer Bus Switch FST3 253
... The Recommended Operating Conditions tables will define the conditions for actual device operation. Note 2: The input and output negative voltage ratings may be exceeded if the input and output diode current ratings are observed. Note 3: Unused control inputs must be held HIGH or LOW. They may not ...
... The Recommended Operating Conditions tables will define the conditions for actual device operation. Note 2: The input and output negative voltage ratings may be exceeded if the input and output diode current ratings are observed. Note 3: Unused control inputs must be held HIGH or LOW. They may not ...
D802A/D802AA M - 深圳市天成音电子科技有限公司
... multi-LED stings or arrays. It can be operated from either universal AC line or any DC voltage between 8-450V. Optionally, a passive power factor correction circuit can be used in order to pass the AC harmonic limits set by EN 61000-3-2 Class C for lighting equipment having input power less than 25W ...
... multi-LED stings or arrays. It can be operated from either universal AC line or any DC voltage between 8-450V. Optionally, a passive power factor correction circuit can be used in order to pass the AC harmonic limits set by EN 61000-3-2 Class C for lighting equipment having input power less than 25W ...
Purpose:
... A breadboard is a device used to facilitate the building and testing (called prototyping) of circuits. The breadboard accepts pre-stripped wires, making it easy to make connections between various electrical components, power supplies, and meters. Breadboards allow circuits to be tested and modified ...
... A breadboard is a device used to facilitate the building and testing (called prototyping) of circuits. The breadboard accepts pre-stripped wires, making it easy to make connections between various electrical components, power supplies, and meters. Breadboards allow circuits to be tested and modified ...
AP8803 Description Pin Assignments
... Figure 3 Switching Frequency vs. Supply Voltage, Inductor, and Number of LEDs Capacitor Selection The small size of ceramic capacitors makes them ideal for AP8803 applications. X5R and X7R types are recommended because they retain their capacitance over wider voltage and temperature ranges than othe ...
... Figure 3 Switching Frequency vs. Supply Voltage, Inductor, and Number of LEDs Capacitor Selection The small size of ceramic capacitors makes them ideal for AP8803 applications. X5R and X7R types are recommended because they retain their capacitance over wider voltage and temperature ranges than othe ...
Rectifier
A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.