• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Maxstar 150 S, STL, And STH
Maxstar 150 S, STL, And STH

... drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe b ...
Feedback
Feedback

UCC29950 CCM PFC and LLC Combo Controller
UCC29950 CCM PFC and LLC Combo Controller

... The SUFG and SUFS are the control pins for an external start-up depletion mode FET. The use of a switched device here eliminates the static power dissipation in a conventional resistive start-up approach where a drop resistor from the rectified AC line to VCC is typically used. As a result standby p ...
Definitions
Definitions

OC20-60 Manual Rev2e
OC20-60 Manual Rev2e

... battery sufficiently and ensure that there are no sources of flames or sparks in the Disconnect all loads connected to the battery during equalization. The voltage applied to the battery during this process may be above safe levels for some loads. ...
Power-Up 3-State (PU3S) Circuits in TI Standard Logic Devices
Power-Up 3-State (PU3S) Circuits in TI Standard Logic Devices

Conduction Losses and Common Mode EMI Analysis on
Conduction Losses and Common Mode EMI Analysis on

... sensing. It should be noted that switches S1 and S2 in both Dual Boost and Two-circuit-boost PFC are operated simultaneously by the same gate signal from the controller. Although both switches are always gated, only one switch, on which the positive input voltage is induced, carries positive current ...
MAX5039, MAX5040
MAX5039, MAX5040

... Scope shots are of the MAX5040 EV kit. Figures 1 through 8 demonstrate system performance of the MAX5040 under various power-up, power-down, and fault conditions. In some cases (described in detail below), startup or shutdown of the I/O and CORE supplies were purposely delayed with respect to each o ...
AX-SIGFOX - Ultra-Low Power, AT Command Controlled, Sigfox
AX-SIGFOX - Ultra-Low Power, AT Command Controlled, Sigfox

... 1. If VDD_IO ramps cannot be guaranteed, an external reset circuit is recommended, see the AX8052 Application Note: Power On Reset 2. The output power of the AX−Sigfox can be programmed in 1 dB steps from 0 dBm – 14 dBm. Current consumption values are given for a matching network that is optimized f ...
ANALYSIS OF FAULTS IN OVERHEAD TRANSMISSION LINES
ANALYSIS OF FAULTS IN OVERHEAD TRANSMISSION LINES

2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System
2.5 Electrical Power 2.5.1 Class 1E Emergency Power Supply System

... non-safety-related plant loads during normal and abnormal operations. EPSS divisions are independent and physically separated during normal bus alignments. An alternate feed is provided between EPSS divisions 1 and 2, and between divisions 3 and 4 to provide the normal and standby source of power to ...
Modeling and Simulation of Transient Fault Response at
Modeling and Simulation of Transient Fault Response at

... owned by E.ON. One of these faults was a two phase short circuit fault, caused by colliding overhead lines and the other fault was a one phase to ground fault due to a lightning strike at the overhead line. Neither one of these faults caused any wind turbine to trip inside the farm, while other prod ...
A Study of Successive Approximation Registers and Implementation of an Ultra-
A Study of Successive Approximation Registers and Implementation of an Ultra-

... logics including the conventional structures and the delay line based controller. Additionally, it focuses on selection of suitable dynamic comparator architecture. Based on this analysis, dynamic two-stage comparator is selected due to its energy efficiency and capability of working in low supply v ...
Generation.
Generation.

... Dr ELECTRODE M A Panneerselvam,GAP Professor, Anna University ...
Medium Voltage Distribution Catalogue 2015
Medium Voltage Distribution Catalogue 2015

... and process an unbalanced load flow algorithm based on that model together with telemetered real-time data recovered from the network. FDIR can operate in manual or automatic mode. In manual mode, post fault, the system will recommend the switching steps required to isolate the minimum faulty line s ...
LITERATURE REVIEW CHAPTER 2
LITERATURE REVIEW CHAPTER 2

... figure is switched at a time and efficiency is 100% [31]. However, the use of this PA at high frequencies is limited due to prominent parasitic reactances that lead to substantial losses. This high-frequency performance degradation is less severe in current-mode Class-D implementations [36]. Class-S ...
DG3257 - Vishay
DG3257 - Vishay

... isolation at -33 dB. Fabricated with high density sub micro CMOS process, the DG3257 provides low parasitic capacitance, handles bidirectional signal flow with minimized phase distortion. Guaranteed 1.4 V logic high threshold makes it possible to interface directly with low voltage MCUs. ...
AN1653 ASB205-MPX5000 Series Sensor Module
AN1653 ASB205-MPX5000 Series Sensor Module

... pin 2. As shipped, KGND is tied to GND via jumper J1. If J1 is opened, KGND provides a separate return for the temperature sensor. This feature can be helpful if a cable is used between the sensor module and its controller. ...
autorización para la digitalización, depósito y divulgación en acceso
autorización para la digitalización, depósito y divulgación en acceso

... attractive. Users get paid if they produce more energy than they consume. Small wind turbines are less popular but still becoming more present in isolated households. This projects aims at managing a hybrid small power generating station. By combining solar and wind resources the power output is mor ...
On Control of Grid-connected Voltage Source Converters
On Control of Grid-connected Voltage Source Converters

... power electronics in distribution and transmission networks, respectively. Custom Power is the application of power electronics to improve the quality of power distribution for sensitive industrial plants. Power electronic converters connected in shunt or series with the grid and equipped with energ ...
UXN6M9M Datasheet 9 GHz Divide-by
UXN6M9M Datasheet 9 GHz Divide-by

... frequency, assuming that the divide controls are updated within one output cycle of the output rising edge. This means for a given input frequency, all divide ratios above the minimum recommended divide ratio will achieve smooth divisions, whereas any divide ratio below the minimum may produce momen ...
Electric Power System Basics for the Nonelectrical Professional
Electric Power System Basics for the Nonelectrical Professional

LTM4602 - 6A High Efficiency DC/DC uModule
LTM4602 - 6A High Efficiency DC/DC uModule

... switching DC/DC power supply. It can deliver up to 6A of DC output current with only bulk external input and output capacitors. This module provides a precisely regulated output voltage programmable via one external resistor from 0.6VDC to 5.0VDC, not to exceed 80% of the input voltage. The input vo ...
S230-30-4
S230-30-4

... banks is warranted for a period of one year from the date of shipment. Cooper Power Systems will, at its option, correct, by repair or replacement, capacitor blocks or components which may fail because of defects in material or workmanship. The warranty is valid only if the equipment has been inspec ...
2.3 Mounting the Solar charger controller
2.3 Mounting the Solar charger controller

... Protect all wiring from physical damage, vibration and excessive heat. Insure that the controller is properly setup for the battery being charged. Do not expose controller to rain or snow. Insure all terminating connections are clean and tight to prevent arcing and overheating. Charging system must ...
< 1 ... 100 101 102 103 104 105 106 107 108 ... 1376 >

Rectifier



A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report