Download T3200 Datasheet
... actual insulation level, either by means of two instruments simultaneously indicating for both insulation systems (I and II), or by means of one instrument which can be connected to the two instrument outputs via a change-over switch. See connection diagram. ...
... actual insulation level, either by means of two instruments simultaneously indicating for both insulation systems (I and II), or by means of one instrument which can be connected to the two instrument outputs via a change-over switch. See connection diagram. ...
FL7930B Single-Stage Flyback and Boundary-Mode PFC Controller for Lighting
... FL7930B provides over-voltage protection (OVP), openfeedback protection, over-current protection (OCP), input-voltage-absent detection, and under-voltage lockout protection (UVLO). The additional OVP pin can be used to shut down the boost power stage when output voltage exceeds OVP level due to the ...
... FL7930B provides over-voltage protection (OVP), openfeedback protection, over-current protection (OCP), input-voltage-absent detection, and under-voltage lockout protection (UVLO). The additional OVP pin can be used to shut down the boost power stage when output voltage exceeds OVP level due to the ...
MAX15034 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications General Description
... MOSFETs and is capable of providing more than 25A of load current. The MAX15034 uses average currentmode control with a switching frequency up to 1MHz per phase where each phase is 180° out of phase with respect to the other. Out-of-phase operation results in significantly reduced input capacitor ri ...
... MOSFETs and is capable of providing more than 25A of load current. The MAX15034 uses average currentmode control with a switching frequency up to 1MHz per phase where each phase is 180° out of phase with respect to the other. Out-of-phase operation results in significantly reduced input capacitor ri ...
RC Circuits - Chabot College
... of the voltages across the resistor and capacitor. Pause at any time using the pause button below. Do the graphs match the expected theoretical results? Estimate the voltage value at a specific time from the graphs (like 1/RC, the time constant!), and verify your equations predicted that value. Reco ...
... of the voltages across the resistor and capacitor. Pause at any time using the pause button below. Do the graphs match the expected theoretical results? Estimate the voltage value at a specific time from the graphs (like 1/RC, the time constant!), and verify your equations predicted that value. Reco ...
60VIN, 3A Synchronous Buck Regulator
... return path for the step-down regulator power stage and should be tied together. The negative terminal of the input decoupling capacitor should be placed as close as possible to these pins. Switch Node. The SW pins are the internal power switch outputs. These pins should be tied together and connect ...
... return path for the step-down regulator power stage and should be tied together. The negative terminal of the input decoupling capacitor should be placed as close as possible to these pins. Switch Node. The SW pins are the internal power switch outputs. These pins should be tied together and connect ...
Leroy Somer Brushless AC Generators
... must be included in the secondary interconnection loop. B) When different size generators are paralleled all paralleling current transformers must have the same proportional ratios that give approximately the same secondary current. C) Voltage regulator paralleling circuitry must be the same. D) ...
... must be included in the secondary interconnection loop. B) When different size generators are paralleled all paralleling current transformers must have the same proportional ratios that give approximately the same secondary current. C) Voltage regulator paralleling circuitry must be the same. D) ...
MAX17710 Energy-Harvesting Charger and Protector General Description Features
... Whenever a harvest source pulls the CHG pin above 5.3V, an internal shunt regulator enables a path to GND to limit the voltage at the CHG pin. The internal shunt path can sustain currents up to 50mA. If it is possible for the harvest source to exceed this power limit, an external protection circuit ...
... Whenever a harvest source pulls the CHG pin above 5.3V, an internal shunt regulator enables a path to GND to limit the voltage at the CHG pin. The internal shunt path can sustain currents up to 50mA. If it is possible for the harvest source to exceed this power limit, an external protection circuit ...
SH-1 Embedded Workhorse User Manual Version 1.0 January 1999 Xtreme Ideas Technology Development
... The SH1EW can be powered from one of two sources, but never by both at the same time. 2.1.1 Powering via unregulated power input There are two possible points for attaching unregulated power. One may either provide power through the expansion headers, or by directly soldering wires to the board. A s ...
... The SH1EW can be powered from one of two sources, but never by both at the same time. 2.1.1 Powering via unregulated power input There are two possible points for attaching unregulated power. One may either provide power through the expansion headers, or by directly soldering wires to the board. A s ...
L44095762
... ABSTRACT-In the present system demand of electrical power increases so fast and transfer of electrical power is need of today‟s scenario. . The electrical power is transfer at same frequency through AC transmission line. However, power generation may be at different frequencies such as wind generati ...
... ABSTRACT-In the present system demand of electrical power increases so fast and transfer of electrical power is need of today‟s scenario. . The electrical power is transfer at same frequency through AC transmission line. However, power generation may be at different frequencies such as wind generati ...
Power Quality Issues, Disturbance Sources, Financial Impacts
... 1996 Version of the IT Industry Tolerance Curves (update from original CBEMA curve). The vertical axis is percent of nominal voltage. "Well-designed" equipment should be able to tolerate any power event that lies in the shaded area. Note that the curve includes sags, swells, and transient overvoltag ...
... 1996 Version of the IT Industry Tolerance Curves (update from original CBEMA curve). The vertical axis is percent of nominal voltage. "Well-designed" equipment should be able to tolerate any power event that lies in the shaded area. Note that the curve includes sags, swells, and transient overvoltag ...
MAX8529 1.5MHz Dual 180° Out-of-Phase PWM Step-Down Controller with POR General Description
... 1.5MHz with an external resistor. Alternatively, the controller can be synchronized to an external clock generated to another MAX8529 or a system clock. One MAX8529 can be set to generate an in-phase, or 90degree out-of-phase, clock signal for synchronization with additional controllers. This allows ...
... 1.5MHz with an external resistor. Alternatively, the controller can be synchronized to an external clock generated to another MAX8529 or a system clock. One MAX8529 can be set to generate an in-phase, or 90degree out-of-phase, clock signal for synchronization with additional controllers. This allows ...
NCP1014STBUCGEVB Non-isolated Positive Output Buck AC/DC Converter Evaluation Board
... particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC ...
... particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC ...
MAX40200 - Part Number Search
... blocks reverse-voltages and passes current when forwardbiased just as a normal diode. The improvements are that instead of a cut-in voltage around 500mV and a logarithmic voltage-current transfer curve, the MAX40200 has a near constant voltage drop independent of the magnitude of the forward current ...
... blocks reverse-voltages and passes current when forwardbiased just as a normal diode. The improvements are that instead of a cut-in voltage around 500mV and a logarithmic voltage-current transfer curve, the MAX40200 has a near constant voltage drop independent of the magnitude of the forward current ...
Instruction manual
... of appliances or portable equipment with transient overvoltages of an average level. Example: appliances and portable equipment CATⅢ: The CATⅢ circuits are power supply circuits of power equipment with high transient overvoltages. Example: fixed installation or industrial equipment CAT Ⅳ : The CAT Ⅳ ...
... of appliances or portable equipment with transient overvoltages of an average level. Example: appliances and portable equipment CATⅢ: The CATⅢ circuits are power supply circuits of power equipment with high transient overvoltages. Example: fixed installation or industrial equipment CAT Ⅳ : The CAT Ⅳ ...
GENERAL SPECIFICATIONS OF INDUCTIVE AND CAPACITIVE
... earlier, in the reduction factors. All the sensors are protected against inversion of polarity and electrical disturbances of inductive sources and can be supplied with short circuit protection in the D.C. version. The main advantages offered by proximity sensors in relation to normal limit switches ...
... earlier, in the reduction factors. All the sensors are protected against inversion of polarity and electrical disturbances of inductive sources and can be supplied with short circuit protection in the D.C. version. The main advantages offered by proximity sensors in relation to normal limit switches ...
AN11 - Designing Linear Circuits for 5V Single Supply Operation
... will function from a 5V supply and achieving good precision in a design is difficult. The circuits in Figure 6 meet these requirements. They also feature input protection, filtering capability and a shield driving output. In Figure 6a, A1, A2 and A3 accomplish the differential input-to-single-ended ou ...
... will function from a 5V supply and achieving good precision in a design is difficult. The circuits in Figure 6 meet these requirements. They also feature input protection, filtering capability and a shield driving output. In Figure 6a, A1, A2 and A3 accomplish the differential input-to-single-ended ou ...
GB3411111120
... capacitor. The voltage ripple is specified with the precision of the MPPT. A larger ripple will render a larger fluctuation around the MPPT operation point. As for the coupling capacitor Cs, it has to flow the maximum input current pulse, and a small ESR is required for reducing the loss. In this pa ...
... capacitor. The voltage ripple is specified with the precision of the MPPT. A larger ripple will render a larger fluctuation around the MPPT operation point. As for the coupling capacitor Cs, it has to flow the maximum input current pulse, and a small ESR is required for reducing the loss. In this pa ...
AN2794
... The basic operation of a voltage fed push-pull converter is shown in Figure 5, where theoretical converter waveforms are highlighted. In practice, significant overvoltages across devices M1, M2 and across the four rectifier diodes are observed in most cases due to the leakage inductance of the high ...
... The basic operation of a voltage fed push-pull converter is shown in Figure 5, where theoretical converter waveforms are highlighted. In practice, significant overvoltages across devices M1, M2 and across the four rectifier diodes are observed in most cases due to the leakage inductance of the high ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.