TLE2027-EP Excalibur™ LOW-NOISE HIGH-SPEED PRECISION OPERATIONAL AMPLIFIER FEATURES
... Initial Estimates of Parameter Distributions In the ongoing program of improving data sheets and supplying more information to our customers, Texas Instruments has added an estimate of not only the typical values but also the spread around these values. These are in the form of distribution bars tha ...
... Initial Estimates of Parameter Distributions In the ongoing program of improving data sheets and supplying more information to our customers, Texas Instruments has added an estimate of not only the typical values but also the spread around these values. These are in the form of distribution bars tha ...
- SIGLENT Technologies
... To couple the frequency selection between two channels, press Utility > CH Copy Coupling > FreqCoupl = ON. Now, any changes in frequency on either channel will be applied to the other channel. This allows you to simultaneously change both frequencies. To copy settings from one channel to another, pr ...
... To couple the frequency selection between two channels, press Utility > CH Copy Coupling > FreqCoupl = ON. Now, any changes in frequency on either channel will be applied to the other channel. This allows you to simultaneously change both frequencies. To copy settings from one channel to another, pr ...
TPS62684 - Texas Instruments
... Operating beyond the continuous average output current of 890mA may decrease the lifetime. See the Thermal, Lifetime Information and Maximum Output Current section. Due to the dc bias effect of ceramic capacitors, the effective capacitance is lower than the nominal value when a voltage is applied. T ...
... Operating beyond the continuous average output current of 890mA may decrease the lifetime. See the Thermal, Lifetime Information and Maximum Output Current section. Due to the dc bias effect of ceramic capacitors, the effective capacitance is lower than the nominal value when a voltage is applied. T ...
4.7-V to 60-V Input, 50-mA Synchronous Step
... using an external resistor to ground to set the switching frequency. If the pin is pulled above the PLL upper threshold, a mode change occurs and the pin becomes a synchronization input. The internal amplifier is disabled and the pin is a high impedance clock input to the internal PLL. If clocking e ...
... using an external resistor to ground to set the switching frequency. If the pin is pulled above the PLL upper threshold, a mode change occurs and the pin becomes a synchronization input. The internal amplifier is disabled and the pin is a high impedance clock input to the internal PLL. If clocking e ...
TPS75201 数据资料 dataSheet 下载
... The RESET (SVS, POR, or power on reset) output of the TPS752xxQ initiates a reset in microcomputer and microprocessor systems in the event of an undervoltage condition. An internal comparator in the TPS752xxQ monitors the output voltage of the regulator to detect an undervoltage condition on the reg ...
... The RESET (SVS, POR, or power on reset) output of the TPS752xxQ initiates a reset in microcomputer and microprocessor systems in the event of an undervoltage condition. An internal comparator in the TPS752xxQ monitors the output voltage of the regulator to detect an undervoltage condition on the reg ...
LT5571 - 620MHz – 1100MHz High Linearity Direct Quadrature Modulator.
... signal combiner/balun, an LO quadrature phase generator and LO buffers. External I and Q baseband signals are applied to the differential baseband input pins, BBPI, BBMI, and BBPQ, BBMQ. These voltage signals are converted to currents and translated to RF frequency by means of double-balanced up-con ...
... signal combiner/balun, an LO quadrature phase generator and LO buffers. External I and Q baseband signals are applied to the differential baseband input pins, BBPI, BBMI, and BBPQ, BBMQ. These voltage signals are converted to currents and translated to RF frequency by means of double-balanced up-con ...
L045076774
... important, but less critical or highly sensitive equipment. It is also used as a complement to more comprehensive power protection solutions. They are passive electronic devices that protect against transient high-level voltages. However, low frequency surges (slow changes at 400 Hz or less) can be ...
... important, but less critical or highly sensitive equipment. It is also used as a complement to more comprehensive power protection solutions. They are passive electronic devices that protect against transient high-level voltages. However, low frequency surges (slow changes at 400 Hz or less) can be ...
AP9060 Description Pin Assignments
... The clamp voltage on AP9060 is set to 11.15V (typically at room temperature). Therefore, the sensitive circuitry will not be exposed to a voltage greater than 11.15V. As a consequence, it is important to ensure that the sensitive ICs that follow AP9060 are safe to operate up to the clamp ...
... The clamp voltage on AP9060 is set to 11.15V (typically at room temperature). Therefore, the sensitive circuitry will not be exposed to a voltage greater than 11.15V. As a consequence, it is important to ensure that the sensitive ICs that follow AP9060 are safe to operate up to the clamp ...
BC847BVN Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
I. Introduction
... The HPS lamps, as any other HID lamps, need ballast to operate correctly. The ballast is additional equipment connected between the power line and the discharge lamp. The ballast has two main functions: to guarantee lamps ignition through the application of a high voltage pulse between the lamp elec ...
... The HPS lamps, as any other HID lamps, need ballast to operate correctly. The ballast is additional equipment connected between the power line and the discharge lamp. The ballast has two main functions: to guarantee lamps ignition through the application of a high voltage pulse between the lamp elec ...
Explicit log domain root-mean
... of the mean-square of the input signal I,-. A multiplier 38 multiplies the log mean-square voltage signal V3 by a root factor of one~half to produce a log RMS voltage signal V4. An exponentiator 40 removes the logarithmic dependence of V4, and produces an output signal I0“, that tracks the RMS value ...
... of the mean-square of the input signal I,-. A multiplier 38 multiplies the log mean-square voltage signal V3 by a root factor of one~half to produce a log RMS voltage signal V4. An exponentiator 40 removes the logarithmic dependence of V4, and produces an output signal I0“, that tracks the RMS value ...
RC Circuits
... begins to build across the plates, thus opposing the action of the battery. As a consequence, the current flowing in the circuit gets less and less (i.e. it decays), falling to zero when the “back-voltage” on the capacitor is exactly equal and opposite to the battery voltage. If we were to quickly d ...
... begins to build across the plates, thus opposing the action of the battery. As a consequence, the current flowing in the circuit gets less and less (i.e. it decays), falling to zero when the “back-voltage” on the capacitor is exactly equal and opposite to the battery voltage. If we were to quickly d ...
4 RC Circuits Experiment 4.1
... begins to build across the plates, thus opposing the action of the battery. As a consequence, the current flowing in the circuit gets less and less (i.e. it decays), falling to zero when the “back-voltage” on the capacitor is exactly equal and opposite to the battery voltage. If we were to quickly d ...
... begins to build across the plates, thus opposing the action of the battery. As a consequence, the current flowing in the circuit gets less and less (i.e. it decays), falling to zero when the “back-voltage” on the capacitor is exactly equal and opposite to the battery voltage. If we were to quickly d ...
a Micropower, Step-Up/Step-Down SW ADP1111
... inductance, saturation current and dc resistance must be determined. This process is not difficult, and specific equations for each circuit configuration are provided in this data sheet. In general terms, however, the inductance value must be low enough to store the required amount of energy (when b ...
... inductance, saturation current and dc resistance must be determined. This process is not difficult, and specific equations for each circuit configuration are provided in this data sheet. In general terms, however, the inductance value must be low enough to store the required amount of energy (when b ...
74LCX16244 Low Voltage 16-Bit Buffer/Line Driver with 5V Tolerant Inputs and Outputs 7
... 3-STATE standard outputs. The device is nibble (4 bits) controlled with each nibble functioning identically, but independent of the other. The control pins can be shorted together to obtain full 16-bit operation. The 3-STATE out- ...
... 3-STATE standard outputs. The device is nibble (4 bits) controlled with each nibble functioning identically, but independent of the other. The control pins can be shorted together to obtain full 16-bit operation. The 3-STATE out- ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.