DRV604 数据资料 dataSheet 下载
... and total harmonic distortion (THD) are low. A good low equivalent-series-resistance (ESR) ceramic capacitor, typically 1µF, placed as close as possible to the device PVDD leads works best. Placing this decoupling capacitor close to the DRV604 is important for the performance of the amplifier. For f ...
... and total harmonic distortion (THD) are low. A good low equivalent-series-resistance (ESR) ceramic capacitor, typically 1µF, placed as close as possible to the device PVDD leads works best. Placing this decoupling capacitor close to the DRV604 is important for the performance of the amplifier. For f ...
AD5441: 英文产品数据手册下载
... be loaded under microprocessor control into a 12-bit shift register and then transferred, in parallel, to the 12-bit DAC register. The analog portion of the AD5441 contains an inverted R-2R ladder network consisting of silicon-chrome, highly stable (50 ppm/°C), thin-film resistors, and 12 pairs of N ...
... be loaded under microprocessor control into a 12-bit shift register and then transferred, in parallel, to the 12-bit DAC register. The analog portion of the AD5441 contains an inverted R-2R ladder network consisting of silicon-chrome, highly stable (50 ppm/°C), thin-film resistors, and 12 pairs of N ...
2.2nV/ Hz, Low-Power, 36V, OPERATIONAL AMPLIFIER √
... LOW VOLTAGE NOISE: 2.2nV/√Hz at 1kHz 0.1Hz to 10Hz NOISE: 130nVPP ...
... LOW VOLTAGE NOISE: 2.2nV/√Hz at 1kHz 0.1Hz to 10Hz NOISE: 130nVPP ...
Users guide and maintenance manual Leroy Somer Alternators LSA
... protection of personnel, in force in the country of use, and has been correctly installed on the alternator power output as close as possible to the alternator. (In this case, disconnect the wire of the interference suppression module linking the neutral). - Any protective devices in place have not ...
... protection of personnel, in force in the country of use, and has been correctly installed on the alternator power output as close as possible to the alternator. (In this case, disconnect the wire of the interference suppression module linking the neutral). - Any protective devices in place have not ...
Orderly power-up of XC87x and XC85x devices
... Advance Design System™ (ADS) of Agilent Technologies, AMBA™, ARM™, MULTI-ICE™, KEIL™, PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigatio ...
... Advance Design System™ (ADS) of Agilent Technologies, AMBA™, ARM™, MULTI-ICE™, KEIL™, PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigatio ...
NA-277 277V to 120V Step Down Transformer
... Steps 277 volts line voltage down to 120 volts. Attaches to knockout on first fixture's junction box in a circuit and is 300VA, 150VA or 50VA rated. NA-277 is a UL Recognized component. To calculate usable load, de-rated by 25%. ...
... Steps 277 volts line voltage down to 120 volts. Attaches to knockout on first fixture's junction box in a circuit and is 300VA, 150VA or 50VA rated. NA-277 is a UL Recognized component. To calculate usable load, de-rated by 25%. ...
FEATURES DESCRIPTION D
... range of 7V to 15V or dual power supplies of ±3.5V to ±7.5V for design flexibility. In single-supply operation, the input common-mode range extends below ground. At maximum output current, a wide output swing provides a 12Vp-p capability with a nominal 15V supply. The OPA561 is internally protected ...
... range of 7V to 15V or dual power supplies of ±3.5V to ±7.5V for design flexibility. In single-supply operation, the input common-mode range extends below ground. At maximum output current, a wide output swing provides a 12Vp-p capability with a nominal 15V supply. The OPA561 is internally protected ...
ESD generator discharged into a large ground plane
... ESD generator discharged into a large ground plane. In order to verify the ESD generator model, the discharge into a large ground plane was simulated. The current injected from the ESD generator into a large metal wall was measured, and the generator was numerically modeled as in this figure. The ge ...
... ESD generator discharged into a large ground plane. In order to verify the ESD generator model, the discharge into a large ground plane was simulated. The current injected from the ESD generator into a large metal wall was measured, and the generator was numerically modeled as in this figure. The ge ...
DS90LV110T 1 to 10 LVDS Data/Clock Distributor General Description
... (Low Voltage Differential Signaling) technology for low power, high speed operation. Data paths are fully differential from input to output for low noise generation and low pulse width distortion. The design allows connection of 1 input to all 10 outputs. LVDS I/O enable high speed data transmission ...
... (Low Voltage Differential Signaling) technology for low power, high speed operation. Data paths are fully differential from input to output for low noise generation and low pulse width distortion. The design allows connection of 1 input to all 10 outputs. LVDS I/O enable high speed data transmission ...
LF155/LF156/LF256 LF257 LF355 LF356
... The Temperature Coefficient of the adjusted input offset voltage changes only a small amount (0.5 μV/°C typically) for each mV of adjustment from its original unadjusted value. Common-mode rejection and open-loop voltage gain are also unaffected by offset adjustment. The input bias currents are junc ...
... The Temperature Coefficient of the adjusted input offset voltage changes only a small amount (0.5 μV/°C typically) for each mV of adjustment from its original unadjusted value. Common-mode rejection and open-loop voltage gain are also unaffected by offset adjustment. The input bias currents are junc ...
Pdf - Text of NPTEL IIT Video Lectures
... Indian Institute of Technology, Kharagpur Lecture - 27 DC Shunt Generators (Refer Slide Time: 00:22) ...
... Indian Institute of Technology, Kharagpur Lecture - 27 DC Shunt Generators (Refer Slide Time: 00:22) ...
MAX4450/MAX4451 Ultra-Small, Low-Cost, 210MHz, Single-Supply Op Amps with Rail-to-Rail Outputs General Description
... The MAX4450/MAX4451 are optimized for AC performance. They are not designed to drive highly reactive loads, which decrease phase margin and may produce excessive ringing and oscillation. Figure 2 shows a circuit that eliminates this problem. Figure 3 is a graph of the optimal isolation resistor (RS) ...
... The MAX4450/MAX4451 are optimized for AC performance. They are not designed to drive highly reactive loads, which decrease phase margin and may produce excessive ringing and oscillation. Figure 2 shows a circuit that eliminates this problem. Figure 3 is a graph of the optimal isolation resistor (RS) ...
Differential Amplifiers
... amplifier continues to sense and amplify the difference signal with the same gain. Typically , ICMR is defined as common-mode voltage range over which all MOSFETs remain in the saturation region. Offsets: Output offset voltage (VOS(out)) : It is defined as the voltage which appears at the output o ...
... amplifier continues to sense and amplify the difference signal with the same gain. Typically , ICMR is defined as common-mode voltage range over which all MOSFETs remain in the saturation region. Offsets: Output offset voltage (VOS(out)) : It is defined as the voltage which appears at the output o ...
WT210/WT230 Digital Power Meters
... The built-in 5 mA range lets you measure currents as low as 25 µA. This makes it possible to measure very low currents on such things as intermittent control equipment. The wide current range (5 mA to 20 A) means a single power meter can be used for applications such as Energy Star® measuremnts, to ...
... The built-in 5 mA range lets you measure currents as low as 25 µA. This makes it possible to measure very low currents on such things as intermittent control equipment. The wide current range (5 mA to 20 A) means a single power meter can be used for applications such as Energy Star® measuremnts, to ...
PAM2307 Description Pin Assignments
... The PAM2307 supports a range of input voltages from 2.7V to 5.5V, allowing the use of a single Li+/Li-polymer cell, multiple Alkaline/ NiMH cell,and other standard power sources. The output voltage is adjustable from 0.6V to the input voltage. The PAM2307 employs internal power switch and synchronou ...
... The PAM2307 supports a range of input voltages from 2.7V to 5.5V, allowing the use of a single Li+/Li-polymer cell, multiple Alkaline/ NiMH cell,and other standard power sources. The output voltage is adjustable from 0.6V to the input voltage. The PAM2307 employs internal power switch and synchronou ...
ADS901 数据资料 dataSheet 下载
... supply rails, as shown in Figure 5. Two additional resistors (RT, RB) are necessary to set the correct current through the ladder. However depending on the desired full-scale swing and supply voltage different resistor values might be selected. The trade-offs, when selecting this reference circuit, ...
... supply rails, as shown in Figure 5. Two additional resistors (RT, RB) are necessary to set the correct current through the ladder. However depending on the desired full-scale swing and supply voltage different resistor values might be selected. The trade-offs, when selecting this reference circuit, ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.