IP4788CZ32
... high-speed Transition Minimized Differential Signaling (TMDS) lines to simplify routing and help reducing impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA ov ...
... high-speed Transition Minimized Differential Signaling (TMDS) lines to simplify routing and help reducing impedance discontinuities. All TMDS lines are protected by an impedance-matched diode configuration that minimizes impedance discontinuities caused by typical shunt diodes. The enhanced 60 mA ov ...
Impact of Gate-Length Biasing on Threshold-Voltage Selection
... – No additional process cost – Leakage variability reduction – Finer control over leakage-delay tradeoff ...
... – No additional process cost – Leakage variability reduction – Finer control over leakage-delay tradeoff ...
General Description Features
... The MAX13000E–MAX13005E 6-channel level translators provide the level shifting necessary to allow data transfer in multivoltage systems. Externally applied voltages, VCC and VL, set the logic levels on either side of the device. Logic signals present on the VL side of the device appear as higher vol ...
... The MAX13000E–MAX13005E 6-channel level translators provide the level shifting necessary to allow data transfer in multivoltage systems. Externally applied voltages, VCC and VL, set the logic levels on either side of the device. Logic signals present on the VL side of the device appear as higher vol ...
Exelon Energy Delivery Interconnection Guidelines greater than 2
... operation, a distance relay with no intentional time delay may be required. If the GIC’s generation is greater than 50% of the minimum line section load and they export power on to the EED T&D lines, then Design “C” should be considered. The rest of the protective relay requirements for Design C are ...
... operation, a distance relay with no intentional time delay may be required. If the GIC’s generation is greater than 50% of the minimum line section load and they export power on to the EED T&D lines, then Design “C” should be considered. The rest of the protective relay requirements for Design C are ...
SR Mini HG SYSTEM Hardware Instruction Manual
... (It is not designed for use with medical equipment and nuclear energy.) z This is a Class A instrument. In a domestic environment, this instrument may cause radio interference, in which case the user may be required to take additional measures. z This instrument is protected from electric shock by r ...
... (It is not designed for use with medical equipment and nuclear energy.) z This is a Class A instrument. In a domestic environment, this instrument may cause radio interference, in which case the user may be required to take additional measures. z This instrument is protected from electric shock by r ...
1395 Digital DC Drive
... contamination of printed circuit boards (PCB), and connections that are damaged or improperly seated, etc., can cause serious malfunctions to occur in the 1395 drive. An attempt should be made to correct any of these environmental conditions prior to installing new components. ...
... contamination of printed circuit boards (PCB), and connections that are damaged or improperly seated, etc., can cause serious malfunctions to occur in the 1395 drive. An attempt should be made to correct any of these environmental conditions prior to installing new components. ...
Line Protection with Distance Relays
... short circuits when plotted on an R-X diagram in terms of the voltages and currents used by distance relays. Chapter 13 gives data from which arc resistance can be estimated for plotting such fault characteristics on the R-X diagram. It is only necessary, then, to superimpose the characteristic of a ...
... short circuits when plotted on an R-X diagram in terms of the voltages and currents used by distance relays. Chapter 13 gives data from which arc resistance can be estimated for plotting such fault characteristics on the R-X diagram. It is only necessary, then, to superimpose the characteristic of a ...
gesis ELECTRONIC - Wieland Electric
... The modular KNX series gesis® FLEX is designed for decentral installation without further housing. A device always consists of a base module and expansion modules. The modules can control lighting, shutters, valves or integrate potential-free contacts with binary inputs in building automation. The m ...
... The modular KNX series gesis® FLEX is designed for decentral installation without further housing. A device always consists of a base module and expansion modules. The modules can control lighting, shutters, valves or integrate potential-free contacts with binary inputs in building automation. The m ...
Installation, Operation and Maintenance Manual
... coupling parts. Even when the motor is stopped, it should be considered “alive” as long as its controller is energized. Automatic circuits may start the motor at any time. Keep hands away from the output shaft until the motor has completely stopped and power is disconnected from the controller. Moto ...
... coupling parts. Even when the motor is stopped, it should be considered “alive” as long as its controller is energized. Automatic circuits may start the motor at any time. Keep hands away from the output shaft until the motor has completely stopped and power is disconnected from the controller. Moto ...
Power Supply Switch - The R-390A Frequently Asked Questions Page
... thermistor causes self-heating, which lowers the device’s resistance. At some point the resistance stabilizes to a value that depends on the equilibrium temperature of the device. The equilibrium temperature is determined by the steady-state current drain of the instrument and the ambient air temper ...
... thermistor causes self-heating, which lowers the device’s resistance. At some point the resistance stabilizes to a value that depends on the equilibrium temperature of the device. The equilibrium temperature is determined by the steady-state current drain of the instrument and the ambient air temper ...
P84905
... The POWERPATH NAC Extender Power Supply is available in two models: the PS-8 and the PS-6. The PS-8 differs from the PS-6 in the NAC output current and in the enclosure size and the PS-8 enclosure can mount up to two addressable control modules. All other features, indicators and capacities are the ...
... The POWERPATH NAC Extender Power Supply is available in two models: the PS-8 and the PS-6. The PS-8 differs from the PS-6 in the NAC output current and in the enclosure size and the PS-8 enclosure can mount up to two addressable control modules. All other features, indicators and capacities are the ...
Theory and Applications of Piezo Actuators and PZT
... The word "piezo" is derived from the Greek word for pressure. In 1880, Jacques and Pierre Curie discovered that pressure applied to a quartz crystal creates an electrical charge in the crystal; they called this phenomena the piezo effect. Later they also verified that an electrical field applied to ...
... The word "piezo" is derived from the Greek word for pressure. In 1880, Jacques and Pierre Curie discovered that pressure applied to a quartz crystal creates an electrical charge in the crystal; they called this phenomena the piezo effect. Later they also verified that an electrical field applied to ...
KEI 2302, 2306 Service
... some instruments and accessories would normally be used with non-hazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid poss ...
... some instruments and accessories would normally be used with non-hazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid poss ...
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-
... R8 The ISO, when notified by the operator of a generating unit of the loss of automatic voltage regulator control, or by the operator of an aggregated generating facility of the loss of voltage regulating system control, must issue a directive or instruction to the operator to maintain or change eit ...
... R8 The ISO, when notified by the operator of a generating unit of the loss of automatic voltage regulator control, or by the operator of an aggregated generating facility of the loss of voltage regulating system control, must issue a directive or instruction to the operator to maintain or change eit ...
Talon SRX – User's Guide Cross The Road
... Multiple Talon SRXs may be driven using a single PWM signal if a Y-Cable equivalent is used to connect multiple PWM inputs to a single PWM output. Note: The PWM period is how fast the robot controller can send a new PWM pulse. The amount of time between the rising edges of two subsequent PWM pulses ...
... Multiple Talon SRXs may be driven using a single PWM signal if a Y-Cable equivalent is used to connect multiple PWM inputs to a single PWM output. Note: The PWM period is how fast the robot controller can send a new PWM pulse. The amount of time between the rising edges of two subsequent PWM pulses ...
User`s Guide UPS 20 - 30 kVA, 230 V 50/60 Hz output (3
... colour, and have safety shields behind the doors for hazardous voltage protection. ...
... colour, and have safety shields behind the doors for hazardous voltage protection. ...
Reference Divider
... mode, the voltage divider resistors are compared using an external null detector to an internal, self-calibrating bridge to precisely set their overall value, and hence~ the division ration of the 752A. The three push-to-tum CALI BRATE controls adjust the 10: I divider, 100:l divider, and the self-c ...
... mode, the voltage divider resistors are compared using an external null detector to an internal, self-calibrating bridge to precisely set their overall value, and hence~ the division ration of the 752A. The three push-to-tum CALI BRATE controls adjust the 10: I divider, 100:l divider, and the self-c ...
Electronic Ballasts - Lighting Research Center
... Information Program (NLPIP) published Specifier Reports: Electronic Ballasts, which provided information about electronic ballasts and performance data for specific manufacturers’ products. Since then, new manufacturers have introduced electronic ballasts, and manufacturers represented in the previo ...
... Information Program (NLPIP) published Specifier Reports: Electronic Ballasts, which provided information about electronic ballasts and performance data for specific manufacturers’ products. Since then, new manufacturers have introduced electronic ballasts, and manufacturers represented in the previo ...
Power electronics
Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)