Datasheet - STMicroelectronics
... When VCC falls below 1 V, the RST (STM809/811) output no longer sinks current, but becomes an open circuit. In most systems this is not a problem, as most MCUs do not operate below 1 V. However, in applications where RST output must be valid down to 0 V, a pull-down resistor may be added to hold the ...
... When VCC falls below 1 V, the RST (STM809/811) output no longer sinks current, but becomes an open circuit. In most systems this is not a problem, as most MCUs do not operate below 1 V. However, in applications where RST output must be valid down to 0 V, a pull-down resistor may be added to hold the ...
EEE529:Microsystems
... (vibration) in their operation. However, some micromachining filters are not mechanical waves processors. Based on the frequency band they transmit, MEMS filters can be classified as low pass, high pass, band pass or band stop filters. Band pass filters are the most common ones in communication. To ...
... (vibration) in their operation. However, some micromachining filters are not mechanical waves processors. Based on the frequency band they transmit, MEMS filters can be classified as low pass, high pass, band pass or band stop filters. Band pass filters are the most common ones in communication. To ...
Paper Title (use style: paper title)
... creates an anti-resonance peak. Like in the case of the 10µ decoupling capacitors, because the ESR of a 100nF is 54.325mΩ, it can be used only a single capacitor to decouple the system and meet the 125mΩ target impedance. In the next two figures, 9 and 10 is presented the result of the simulation us ...
... creates an anti-resonance peak. Like in the case of the 10µ decoupling capacitors, because the ESR of a 100nF is 54.325mΩ, it can be used only a single capacitor to decouple the system and meet the 125mΩ target impedance. In the next two figures, 9 and 10 is presented the result of the simulation us ...
DEEP SEA ELECTRONICS DSE8600 Series PC configuration suite
... All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents ...
... All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents ...
Quality is our Drive. Braking Devices BR 230/400
... X5,X6) closes. The motor can be started. A starting logic makes sure that braking is not yet initiated when the plant is switched on with the master switch while the motor is still switched off. The fully automatic run of the braking interval starts with the switch-off of the motor contactor which a ...
... X5,X6) closes. The motor can be started. A starting logic makes sure that braking is not yet initiated when the plant is switched on with the master switch while the motor is still switched off. The fully automatic run of the braking interval starts with the switch-off of the motor contactor which a ...
Effects of Smoke on Functional Circuits NUREG/CR-6543 SAND97-2544
... The high-speed digital circuit was not affected by smoke, even at the highest fuel level. The main component tested in this circuit was an advanced TTL (FAST) chip. An experiment that compared the failure of chip technologies in the presence of a shunt resistance showed that a FAST chip is one of th ...
... The high-speed digital circuit was not affected by smoke, even at the highest fuel level. The main component tested in this circuit was an advanced TTL (FAST) chip. An experiment that compared the failure of chip technologies in the presence of a shunt resistance showed that a FAST chip is one of th ...
AN3137 - STMicroelectronics
... Internal analog channels (internal reference voltage and temperature sensor) can be used for calibration purposes (or for temperature measurement). These analog sources must be enabled before using them (they are disabled by default so as to save power). ...
... Internal analog channels (internal reference voltage and temperature sensor) can be used for calibration purposes (or for temperature measurement). These analog sources must be enabled before using them (they are disabled by default so as to save power). ...
characterization, modeling, and design of esd
... This thesis reviews the problems of ESD in the IC industry and the standard models used to characterize ESD protection-circuit performance. Previous approaches to ESD circuit design are discussed, including design theory and specific design examples. Transmissionline pulsing (TLP), a relatively new ...
... This thesis reviews the problems of ESD in the IC industry and the standard models used to characterize ESD protection-circuit performance. Previous approaches to ESD circuit design are discussed, including design theory and specific design examples. Transmissionline pulsing (TLP), a relatively new ...
FR-A500 INSTRUCTION MANUAL
... (1) Transportation and installation CAUTION ! When carrying products, use correct lifting gear to prevent injury. ! Do not stack the inverter boxes higher than the number recommended. ! Ensure that installation position and material can withstand the weight of the inverter. Install according to the ...
... (1) Transportation and installation CAUTION ! When carrying products, use correct lifting gear to prevent injury. ! Do not stack the inverter boxes higher than the number recommended. ! Ensure that installation position and material can withstand the weight of the inverter. Install according to the ...
P84662
... D. Select the delay, before AC loss trouble will be reported to the common trouble terminals (JP1) to either SHORT DLY or LONG DLY. LONG DLY is 170 minutes and SHORT DLY is 30 seconds. E. If using the optional PS-4CA module install it now. F. Dress the battery wires down to the back of the enclosure ...
... D. Select the delay, before AC loss trouble will be reported to the common trouble terminals (JP1) to either SHORT DLY or LONG DLY. LONG DLY is 170 minutes and SHORT DLY is 30 seconds. E. If using the optional PS-4CA module install it now. F. Dress the battery wires down to the back of the enclosure ...
Potential Transformer
... As winding is common in both circuits, most of the energy is transferred by means of electrical conduction and a small part is transferred through induction. ...
... As winding is common in both circuits, most of the energy is transferred by means of electrical conduction and a small part is transferred through induction. ...
E2E/E2E2 - OMRON – Automação Industrial
... Note 1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface condition (the PLC’s ON voltage, for example) when connecting the Proximity Sensor to a load. 2. The standard cable length is 300 mm. Models are also available with 500 ...
... Note 1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface condition (the PLC’s ON voltage, for example) when connecting the Proximity Sensor to a load. 2. The standard cable length is 300 mm. Models are also available with 500 ...
14-Bit, 80 MSPS, A/D Converter AD9444 FEATURES
... The AD9444 is a 14-bit monolithic, sampling analog-to-digital converter (ADC) with an on-chip, track-and-hold circuit and is optimized for power, small size, and ease of use. The product operates at up to an 80 MSPS conversion rate and is optimized for multicarrier, multimode receivers, such as thos ...
... The AD9444 is a 14-bit monolithic, sampling analog-to-digital converter (ADC) with an on-chip, track-and-hold circuit and is optimized for power, small size, and ease of use. The product operates at up to an 80 MSPS conversion rate and is optimized for multicarrier, multimode receivers, such as thos ...
D-M9N(V) - RS Components International
... operation range by each actuator. Since short circuit protection circuit is not built-in, the auto switch will be immediately damaged when the load is shortcircuited. Be careful not to exchange the power cable (brown) with the output cable (black). ...
... operation range by each actuator. Since short circuit protection circuit is not built-in, the auto switch will be immediately damaged when the load is shortcircuited. Be careful not to exchange the power cable (brown) with the output cable (black). ...
3 - Schneider Electric België
... CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury or property damage. ...
... CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury or property damage. ...
DRAWOUT FEEDERVISION 2 (FVD) Technical
... unit, a member of the P&B Vision range of relays. FVD was specifically designed to be used on medium voltage feeders as an integral part of any type or manufacture of distribution equipment. FVD allows total control, protection and monitoring of distribution and transformer feeders either by direct ...
... unit, a member of the P&B Vision range of relays. FVD was specifically designed to be used on medium voltage feeders as an integral part of any type or manufacture of distribution equipment. FVD allows total control, protection and monitoring of distribution and transformer feeders either by direct ...
provisional model answer key (electrical engineering and
... Q91 A 4-bit Johnson counter is initialized to 0101. Every time the state 1011 is reached, the counter is re-initialized to 0000 at the next clock active edge. Again when the state 0001 is reached, the counter is initialized back to 0101 at ...
... Q91 A 4-bit Johnson counter is initialized to 0101. Every time the state 1011 is reached, the counter is re-initialized to 0000 at the next clock active edge. Again when the state 0001 is reached, the counter is initialized back to 0101 at ...
1746-UM005B, SLC 500 4-Channel Analog I/O Modules
... Quick Start for Experienced Users Required Tools and Equipment . . . . . . . . . . . . . . . . . . . . . 2-1 ...
... Quick Start for Experienced Users Required Tools and Equipment . . . . . . . . . . . . . . . . . . . . . 2-1 ...
RIGOL User’s Guide DG4000 Series Function/Arbitrary Waveform Generator
... (with a mild detergent or water). When cleaning the LCD, take care to avoid scarifying it. ...
... (with a mild detergent or water). When cleaning the LCD, take care to avoid scarifying it. ...
Power electronics

Power electronics is the application of solid-state electronics to the control and conversion of electric power. It also refers to a subject of research in electronic and electrical engineering which deals with the design, control, computation and integration of nonlinear, time-varying energy-processing electronic systems with fast dynamics.The first high power electronic devices were mercury-arc valves. In modern systems the conversion is performed with semiconductor switching devices such as diodes, thyristors and transistors, pioneered by R. D. Middlebrook and others beginning in the 1950s. In contrast to electronic systems concerned with transmission and processing of signals and data, in power electronics substantial amounts of electrical energy are processed. An AC/DC converter (rectifier) is the most typical power electronics device found in many consumer electronic devices, e.g. television sets, personal computers, battery chargers, etc. The power range is typically from tens of watts to several hundred watts. In industry a common application is the variable speed drive (VSD) that is used to control an induction motor. The power range of VSDs start from a few hundred watts and end at tens of megawatts.The power conversion systems can be classified according to the type of the input and output power AC to DC (rectifier) DC to AC (inverter) DC to DC (DC-to-DC converter) AC to AC (AC-to-AC converter)