4.6 Optical Fibres
... a core diameter of 1000microns (1mm). Long distance communication grade fibre is made of very pure silica and has a core diameter of 5 microns or less, about the same size as a human hair. Individual fibre ...
... a core diameter of 1000microns (1mm). Long distance communication grade fibre is made of very pure silica and has a core diameter of 5 microns or less, about the same size as a human hair. Individual fibre ...
Magnetic-field-dependent angular distributions and linear
... M = ±1 sublevels, when the photon’s polarization is neglected. The B dependence of the angular distributions of Aif results from the fact that the MIT transition rate is proportional to B 2 [4]. As an example, we show the angular distributions of the rates in Fig. 1 for the transitions in Ne-like Mg ...
... M = ±1 sublevels, when the photon’s polarization is neglected. The B dependence of the angular distributions of Aif results from the fact that the MIT transition rate is proportional to B 2 [4]. As an example, we show the angular distributions of the rates in Fig. 1 for the transitions in Ne-like Mg ...
Light Years and Our Universe
... Sirius, in the constellation Canis Major, is the sky’s brightest star. It is easy to find on winter and spring evenings. When you look at Sirius, you are looking back in time to see how Sirius looked 8 years ago. The light left the star 8 years ago. So how many light years away is Sirius? 8 l ...
... Sirius, in the constellation Canis Major, is the sky’s brightest star. It is easy to find on winter and spring evenings. When you look at Sirius, you are looking back in time to see how Sirius looked 8 years ago. The light left the star 8 years ago. So how many light years away is Sirius? 8 l ...
A list of some commonly used formulas in optics
... between the two medii at an angle. This angle is called the angle of incidence. It is the angle measured between the normal to the surface (interface) and the incoming light beam (see figure). In the case that n1 is smaller than n2, the light is bent towards the normal. If n1 is greater than n2, the ...
... between the two medii at an angle. This angle is called the angle of incidence. It is the angle measured between the normal to the surface (interface) and the incoming light beam (see figure). In the case that n1 is smaller than n2, the light is bent towards the normal. If n1 is greater than n2, the ...
atomicspectra1-2
... • The multiplicity of the L term is equal to 2S + 1 = 2s + 1 = 2.: doublet : two levels, with J = L ± 1/2, respectively • The Coulomb interaction between the nucleus and the single electron is dominant, so that the largest energy separations are associated with levels having different n • hyperfine ...
... • The multiplicity of the L term is equal to 2S + 1 = 2s + 1 = 2.: doublet : two levels, with J = L ± 1/2, respectively • The Coulomb interaction between the nucleus and the single electron is dominant, so that the largest energy separations are associated with levels having different n • hyperfine ...
reflection, refraction, lense and optical instruments
... is now on the inside of the glass, not the angle the outside of the glass is hit at) where this happens is given the name critical angle since for any θinc > θcritical, the sine would have to greater than 1. Since this can not be, light must be trapped inside the glass, it must be totally reflected. ...
... is now on the inside of the glass, not the angle the outside of the glass is hit at) where this happens is given the name critical angle since for any θinc > θcritical, the sine would have to greater than 1. Since this can not be, light must be trapped inside the glass, it must be totally reflected. ...
Experimental basis for special relativity
... • If there was a medium for light wave propagation, then the speed of light must be measured relative to that medium • Thus the ether could provide an absolute reference frame for all measurements • The ether must have some strange properties – it must be solid-like to support high-frequency transve ...
... • If there was a medium for light wave propagation, then the speed of light must be measured relative to that medium • Thus the ether could provide an absolute reference frame for all measurements • The ether must have some strange properties – it must be solid-like to support high-frequency transve ...
The Electronic Structures of Atoms Electromagnetic Radiation The
... – This is the origin of absorption spectra. ...
... – This is the origin of absorption spectra. ...
electrons - TAMU Chemistry
... Light of a characteristic wavelength (and frequency) is absorbed when electron jumps from lower E (orbit, n = 2) to higher E (orbit, n= 4) – This is the origin of absorption spectra. ...
... Light of a characteristic wavelength (and frequency) is absorbed when electron jumps from lower E (orbit, n = 2) to higher E (orbit, n= 4) – This is the origin of absorption spectra. ...
ATOMIC SPECTRA Theory
... ATOMIC SPECTRA Measurement of the wavelength of light emitted by excited atoms The purpose of this laboratory exercise is to measure the wavelength of light emitted when hydrogen and other atoms make transitions between various energy states. These wavelengths are to be compared to those predicted b ...
... ATOMIC SPECTRA Measurement of the wavelength of light emitted by excited atoms The purpose of this laboratory exercise is to measure the wavelength of light emitted when hydrogen and other atoms make transitions between various energy states. These wavelengths are to be compared to those predicted b ...
5-1-light-quantized-energy
... produces radiation which include radio and TV signals, phone relay stations, light bulbs, medical x-rays equipment, and particle accelerators. O Natural sources on Earth, such as lightning, natural radioactivity, and even the glow of ...
... produces radiation which include radio and TV signals, phone relay stations, light bulbs, medical x-rays equipment, and particle accelerators. O Natural sources on Earth, such as lightning, natural radioactivity, and even the glow of ...
Eva Knoth PH263 – Lab 7 March 30, 2011 The Photoelectric Effect
... voltage vs. current were constructed and fit to trend lines. Analysis Obvious trends are observed between each parameter and current. Current has a non-linear dependence on wavelength. As the wavelength was increased, current decreased. Current appears to be inversely proportional to the square of t ...
... voltage vs. current were constructed and fit to trend lines. Analysis Obvious trends are observed between each parameter and current. Current has a non-linear dependence on wavelength. As the wavelength was increased, current decreased. Current appears to be inversely proportional to the square of t ...