A 1.2- mu m CMOS current-controlled oscillator - Solid
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...
... capacitor CT. Although the unavoidable stray capacitances Cpl and Cpr do not form part of the timing capacitance, they nevertheless have an effect on oscillator timing. In order to overcome this problem, Sneep and Verhoven [12] and Banu [IO] (in a MOS equivalent) replaced the single floating capacit ...
A Novel High Speed Differential Ultra Low-Voltage
... The ever increasing problem associated with modern CMOS processes is the demand for digital CMOS gates operating at low supply voltages. The available supply voltage and threshold voltage is lowered as a consequence of the reduction in transistor length. When the supply voltage is decreased the spee ...
... The ever increasing problem associated with modern CMOS processes is the demand for digital CMOS gates operating at low supply voltages. The available supply voltage and threshold voltage is lowered as a consequence of the reduction in transistor length. When the supply voltage is decreased the spee ...
MAX17242/MAX17243 3.5V–36V, 2A/3A, Synchronous Buck
... can operate in drop-out condition by running at 99% duty cycle. The converters deliver up to 2A (MAX17242) and 3A (MAX17243) output current and generate fixed output voltages of 3.3V/5V, along with the ability to program the output voltage between 1V to 10V. The devices use a current-mode-control ar ...
... can operate in drop-out condition by running at 99% duty cycle. The converters deliver up to 2A (MAX17242) and 3A (MAX17243) output current and generate fixed output voltages of 3.3V/5V, along with the ability to program the output voltage between 1V to 10V. The devices use a current-mode-control ar ...
MAX17498A/MAX17498B/MAX17498C AC-DC and DC-DC Peak Current-Mode Converters for Flyback/Boost Applications
... The MAX17498A/MAX17498B/MAX17498C devices are current-mode fixed-frequency flyback/boost converters with a minimum number of external components. They contain all the control circuitry required to design wide input voltage isolated and nonisolated power supplies. The MAX17498A has its rising/falling ...
... The MAX17498A/MAX17498B/MAX17498C devices are current-mode fixed-frequency flyback/boost converters with a minimum number of external components. They contain all the control circuitry required to design wide input voltage isolated and nonisolated power supplies. The MAX17498A has its rising/falling ...
A NEW TIME DOMAIN MODEL FOR ELECTRIC ARC FURNACE
... models are more helpful for harmonic analysis of the external network. The external network is the model of a linear system considered at each harmonic. In the above explained methods, there are some restrictions such as initial conditions for the differential equations, balanced situation of the th ...
... models are more helpful for harmonic analysis of the external network. The external network is the model of a linear system considered at each harmonic. In the above explained methods, there are some restrictions such as initial conditions for the differential equations, balanced situation of the th ...
Determining Kilowatt Capacity of Data Center Space
... If the space has a dedicated Primary UPS module: 1. Determine the rating of the primary (non‐redundant) UPS unit(s) serving the space. If the unit(s) is rated in kW, this value should be used in calculating the number of kilowatts provided. 2. If the unit is rated in kVa (most battery‐backed UPS) ...
... If the space has a dedicated Primary UPS module: 1. Determine the rating of the primary (non‐redundant) UPS unit(s) serving the space. If the unit(s) is rated in kW, this value should be used in calculating the number of kilowatts provided. 2. If the unit is rated in kVa (most battery‐backed UPS) ...
BD93291EFJ
... H3RegTM, a Rohm proprietary control method which facilitates ultra-high transient response against changes in load. SLLM (Simple Light Load Mode) technology is also integrated to improve efficiency when powering lighter loads. For protection and ease of use, the IC also incorporates soft start. Spac ...
... H3RegTM, a Rohm proprietary control method which facilitates ultra-high transient response against changes in load. SLLM (Simple Light Load Mode) technology is also integrated to improve efficiency when powering lighter loads. For protection and ease of use, the IC also incorporates soft start. Spac ...
DM7446A DM5447A DM7447A BCD to 7
... The 46A and 47A feature active-low outputs designed for driving common-anode LEDs or incandescent indicators directly. All of the circuits have full ripple-blanking input/output controls and a lamp test input. Segment identification and resultant displays are shown on a following page. Display patte ...
... The 46A and 47A feature active-low outputs designed for driving common-anode LEDs or incandescent indicators directly. All of the circuits have full ripple-blanking input/output controls and a lamp test input. Segment identification and resultant displays are shown on a following page. Display patte ...
Technical Specification PQ60120QEx25 35-75V
... the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). ...
... the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). ...
final_report - An-Najah National University
... are the ones that can provide this pay-back. Other ancillary benefits to be gained by correcting power factor are lower energy losses, better voltage regulation and released system capacity. Here we explain the fundamentals of power factor and how shunt capacitor banks can benefit you. All electric ...
... are the ones that can provide this pay-back. Other ancillary benefits to be gained by correcting power factor are lower energy losses, better voltage regulation and released system capacity. Here we explain the fundamentals of power factor and how shunt capacitor banks can benefit you. All electric ...
BDTIC www.BDTIC.com/infineon Industrial Power Control
... Application Example Bipolar Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Application Example Unipolar Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Propagation Delay, Rise and Fall T ...
... Application Example Bipolar Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Application Example Unipolar Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Propagation Delay, Rise and Fall T ...
A Door Motion Energy Harvesting System for Powering an Electronic
... no-load current, INL, no-load speed (in rpm), nNL, stall current, Istall, and/or armature resistance, Ra. These parameters can be combined to determine the motor constant, k, which provides the open-circuit output voltage as a function of shaft speed. The maximum output power for each motor could al ...
... no-load current, INL, no-load speed (in rpm), nNL, stall current, Istall, and/or armature resistance, Ra. These parameters can be combined to determine the motor constant, k, which provides the open-circuit output voltage as a function of shaft speed. The maximum output power for each motor could al ...
AN-1318 LM3501 Evaluation Board (Rev. A)
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain t ...
... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain t ...
IMH23
... 3) Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating char ...
... 3) Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating char ...
Stand-Alone Switch-Mode Lithium-Ion Battery-Charger Controller General Description Features
... with only a ±0.8% total voltage error at the battery terminals. The external N-channel switch and synchronous rectifier provide high efficiency over a wide input voltage range. A built-in safety timer automatically terminates charging once the adjustable time limit has been reached. The MAX1737 regu ...
... with only a ±0.8% total voltage error at the battery terminals. The external N-channel switch and synchronous rectifier provide high efficiency over a wide input voltage range. A built-in safety timer automatically terminates charging once the adjustable time limit has been reached. The MAX1737 regu ...
Wiring Main Circuit and Peripheral Devices
... at only one location (COM_SG) for common signal grounding. If alarm signals for multiple SERVOPACKs are connected in series, an alarm signal may not be received correctly when an alarm is issued. ...
... at only one location (COM_SG) for common signal grounding. If alarm signals for multiple SERVOPACKs are connected in series, an alarm signal may not be received correctly when an alarm is issued. ...
integrated mos gate drivers
... If the electrical isolation is done before the final stage, the gate voltages (VG+, VG-) must be isolated from the other voltages which supply the logic and the interface blocks – Fig.6.1. Also, in the MGDs logic side may be needed more supply voltages. It is possible that some blocks which included ...
... If the electrical isolation is done before the final stage, the gate voltages (VG+, VG-) must be isolated from the other voltages which supply the logic and the interface blocks – Fig.6.1. Also, in the MGDs logic side may be needed more supply voltages. It is possible that some blocks which included ...