NCP1060 - High-Voltage Switcher for Low Power Offline SMPS
... SOIC−16 package, the NCP106X offer a high level of integration, including soft−start, frequency−jittering, short−circuit protection, skip−cycle, adjustable peak current set point, ramp compensation, and a Dynamic Self−Supply (eliminating the need for an auxiliary winding). Unlike other monolithic so ...
... SOIC−16 package, the NCP106X offer a high level of integration, including soft−start, frequency−jittering, short−circuit protection, skip−cycle, adjustable peak current set point, ramp compensation, and a Dynamic Self−Supply (eliminating the need for an auxiliary winding). Unlike other monolithic so ...
ADC / DAC
... When data is in binary form, the 0's and 1's may be of several forms such as the TTL form where the logic zero may be a value up to 0.8 volts and the 1 may be a voltage from 2 to 5 volts. The data can be converted to clean digital form using gates which are designed to be on or off depending on ...
... When data is in binary form, the 0's and 1's may be of several forms such as the TTL form where the logic zero may be a value up to 0.8 volts and the 1 may be a voltage from 2 to 5 volts. The data can be converted to clean digital form using gates which are designed to be on or off depending on ...
MAX16838 Evaluation Kit Evaluates: General Description Features
... Note: The series-connected HB LED string must be rated no less than 200mA. ...
... Note: The series-connected HB LED string must be rated no less than 200mA. ...
12-Bit, Voltage Output DIGITAL-TO
... The reference inputs, VREFL and VREFH, can be any voltage between VSS + 2.25V and VDD – 2.25V provided that VREFH is at least 1.25V greater than VREFL. The minimum output of each DAC is equal to VREFL plus a small offset voltage (essentially, the offset of the output op amp). The maximum output is e ...
... The reference inputs, VREFL and VREFH, can be any voltage between VSS + 2.25V and VDD – 2.25V provided that VREFH is at least 1.25V greater than VREFL. The minimum output of each DAC is equal to VREFL plus a small offset voltage (essentially, the offset of the output op amp). The maximum output is e ...
AP2337 1.0A SINGLE CHANNEL CURRENT-LIMITED LOAD SWITCH Description
... The AP2337 is single channel current-limited integrated highside power switches optimized for hot-swap applications. The devices have fast short-circuit response time for improved overall system robustness and provide a complete protection solution for application subject to heavy capacitive loads a ...
... The AP2337 is single channel current-limited integrated highside power switches optimized for hot-swap applications. The devices have fast short-circuit response time for improved overall system robustness and provide a complete protection solution for application subject to heavy capacitive loads a ...
Comparative Analysis of Series and Parallel Photovoltaic Arrays
... Single-stage central inverter (CI) topologies have been widely used due to its simplicity and high converter efficiency, since it does not requires a step-up dc-dc converter. Normally these PV systems use a large number of modules in series for direct connection of the PV array to the inverter. The ...
... Single-stage central inverter (CI) topologies have been widely used due to its simplicity and high converter efficiency, since it does not requires a step-up dc-dc converter. Normally these PV systems use a large number of modules in series for direct connection of the PV array to the inverter. The ...
TPS65262-1 - Texas Instruments
... range encompasses the most intermediate bus voltage operating off 5-V, 9-V, 12-V, or 15-V power bus. The converter, with constant frequency peak current mode, is designed to simplify its application while giving designers options to optimize the system according to targeted applications. The device ...
... range encompasses the most intermediate bus voltage operating off 5-V, 9-V, 12-V, or 15-V power bus. The converter, with constant frequency peak current mode, is designed to simplify its application while giving designers options to optimize the system according to targeted applications. The device ...
K4 - Technical specification (word)
... 3. Panel interior shall have the following pre-assembled and pre-wired: Suitable divider separating class1 and class 2 compartments Control transformer, UL/CSA approved for class 2 circuits Low voltage relays as required by switched circuits shown on plans or schedules Control devices as req ...
... 3. Panel interior shall have the following pre-assembled and pre-wired: Suitable divider separating class1 and class 2 compartments Control transformer, UL/CSA approved for class 2 circuits Low voltage relays as required by switched circuits shown on plans or schedules Control devices as req ...
Mastech MS8264
... 2. Connect the black and red test leads to the COM and ( terminals respectively. 3. Connect the test leads to the circuit being measured and read the displayed value. Some tips for measuring resistance: ( The measured value of a resistor in a circuit is often different from the resistor's rated valu ...
... 2. Connect the black and red test leads to the COM and ( terminals respectively. 3. Connect the test leads to the circuit being measured and read the displayed value. Some tips for measuring resistance: ( The measured value of a resistor in a circuit is often different from the resistor's rated valu ...
New or Revised Definitions #5 - pes-psrc
... Audio-tone protective relaying. Protective relaying using a voice frequency channel. Audio-tone. See: voice frequency (1) data transmission. Control diagram. A diagram which shows all of the functions that control the operation of an electrical device. Coreless reactor. A shunt reactor having no iro ...
... Audio-tone protective relaying. Protective relaying using a voice frequency channel. Audio-tone. See: voice frequency (1) data transmission. Control diagram. A diagram which shows all of the functions that control the operation of an electrical device. Coreless reactor. A shunt reactor having no iro ...
Improvement of the Electric Power Quality Using Series Active and
... Finally, another approach has recently been proposed [16]. It suggests that the active filter generates a voltage which compensates the passive filter and load reactive power, so it allows the current harmonics to be eliminated. The calculation algorithm is based on the instantaneous reactive power ...
... Finally, another approach has recently been proposed [16]. It suggests that the active filter generates a voltage which compensates the passive filter and load reactive power, so it allows the current harmonics to be eliminated. The calculation algorithm is based on the instantaneous reactive power ...
Module 6: Transformers
... maximum rating that applies when oil pumps and cooling fans are operating. • The forced air (FA) rating applies when the fans are running but the oil pumps are not running (oil is flowing by natural circulation). This is approximately 80% of the maximum rating. • The oil to air (OA) rating applies w ...
... maximum rating that applies when oil pumps and cooling fans are operating. • The forced air (FA) rating applies when the fans are running but the oil pumps are not running (oil is flowing by natural circulation). This is approximately 80% of the maximum rating. • The oil to air (OA) rating applies w ...
MAX44244/MAX44245/MAX44248 36V, Precision, Low-Power, 90µA, Single/Quad/Dual Op Amps General Description
... operation with a wide supply range. The devices incorporate a patented auto-zero circuit that constantly measures and compensates the input offset to eliminate drift over time and temperature as well as the effect of 1/f noise. These devices also feature integrated EMI filters to reduce high-frequen ...
... operation with a wide supply range. The devices incorporate a patented auto-zero circuit that constantly measures and compensates the input offset to eliminate drift over time and temperature as well as the effect of 1/f noise. These devices also feature integrated EMI filters to reduce high-frequen ...
Rockwell Automation Allen-Bradley Specification SMC
... 1. The family of devices must be available from 1 to 480 amps in a line connection 2. The family of devices must be available from 1 to 830 amps when connected inside the delta a. The inside the delta connection should be enabled with a dip switch 3. The power structure shall include an electro-mech ...
... 1. The family of devices must be available from 1 to 480 amps in a line connection 2. The family of devices must be available from 1 to 830 amps when connected inside the delta a. The inside the delta connection should be enabled with a dip switch 3. The power structure shall include an electro-mech ...
Surge Protection Done Right
... protect against larger, more dangerous external surges. This fact is often discovered only when the unit fails, since there is no practical way to determine the life left in such suppressors, or whether they are capable of stopping a dangerous surge! For important applications, use of sacrificial and ...
... protect against larger, more dangerous external surges. This fact is often discovered only when the unit fails, since there is no practical way to determine the life left in such suppressors, or whether they are capable of stopping a dangerous surge! For important applications, use of sacrificial and ...