Lab- Parallel Circuits
... Method – Part A – Series circuit 1. Connect a series circuit. Start at the negative terminal and add on the components in the following order: power source set to 10 V, ammeter, open switch, bulb, resistor. 2. Turn on the source and close the switch. Record the current (IT) in observation Table 1. 3 ...
... Method – Part A – Series circuit 1. Connect a series circuit. Start at the negative terminal and add on the components in the following order: power source set to 10 V, ammeter, open switch, bulb, resistor. 2. Turn on the source and close the switch. Record the current (IT) in observation Table 1. 3 ...
Chapter 6 - AutomationDirect
... to the AC drive output power. 2. Check the wiring connections between the AC drive and motor for possible short circuits. 3. Increase the Acceleration time (P 1-01 or P 1-05). 4. Check for possible excessive loading conditions at the motor. 5. If there are any abnormal conditions when operating the ...
... to the AC drive output power. 2. Check the wiring connections between the AC drive and motor for possible short circuits. 3. Increase the Acceleration time (P 1-01 or P 1-05). 4. Check for possible excessive loading conditions at the motor. 5. If there are any abnormal conditions when operating the ...
Portable Hybrid Recorder DR130
... Max. 80 VA (when 20 input channels are selected) When both AC and DC power are connected to a DC power supply model, which of the power supplies is used depends on the voltage of the DC power supply connected as follows. ...
... Max. 80 VA (when 20 input channels are selected) When both AC and DC power are connected to a DC power supply model, which of the power supplies is used depends on the voltage of the DC power supply connected as follows. ...
DG201 Datasheet
... All Intersil products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at website www.intersil.com/design/quality/iso.asp Intersil products are sold by description only. Intersil Corporation reserves the right to ma ...
... All Intersil products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at website www.intersil.com/design/quality/iso.asp Intersil products are sold by description only. Intersil Corporation reserves the right to ma ...
Now - PCB Piezotronics
... value before applying weld current. After reaching the minimum value, the strain signal is used to immediately trigger weld current, which cuts cycle time and avoids electrode damage due to premature activation. The strain signal may also be used to control the desired force value throughout the wel ...
... value before applying weld current. After reaching the minimum value, the strain signal is used to immediately trigger weld current, which cuts cycle time and avoids electrode damage due to premature activation. The strain signal may also be used to control the desired force value throughout the wel ...
VCM TCM LCM Data Sheet/Manual PDF
... These modules provide a convenient way to adapt RLC Counters to most any machine control voltage signal. They also make it easy to upgrade electromechanical counter installations with RLC Counters. VCM’s are available in two input voltage ranges that cover the spectrum from 4-270 V. The non-polarize ...
... These modules provide a convenient way to adapt RLC Counters to most any machine control voltage signal. They also make it easy to upgrade electromechanical counter installations with RLC Counters. VCM’s are available in two input voltage ranges that cover the spectrum from 4-270 V. The non-polarize ...
Understanding patent claims
... Given knowledge of the prior art, it is not obvious to combine the elements to achieve these new effects → the inventive step requirement is fulfilled. The claim must be changed to distinguish it from US6061253: "A switched-mode power supply with a storage capacitor, a transformer with a primary win ...
... Given knowledge of the prior art, it is not obvious to combine the elements to achieve these new effects → the inventive step requirement is fulfilled. The claim must be changed to distinguish it from US6061253: "A switched-mode power supply with a storage capacitor, a transformer with a primary win ...
Low Power Designs with CoolRunner-II CPLDs
... Many times devices are connected to a data bus which are not being addressed by the master device. When a CPLD is in this situation, it will use more power than necessary since the data on the bus is not useful to the CPLD, but the data lines continue to toggle, which subsequently toggles the intern ...
... Many times devices are connected to a data bus which are not being addressed by the master device. When a CPLD is in this situation, it will use more power than necessary since the data on the bus is not useful to the CPLD, but the data lines continue to toggle, which subsequently toggles the intern ...
DATA SHEET PBSS5240T 40 V, 2 A
... any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Limiting values ⎯ Stress above one or more limiting values (as defined in the Absolu ...
... any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Limiting values ⎯ Stress above one or more limiting values (as defined in the Absolu ...
Common AC Power Distribution Configurations
... Email : [email protected] Email : [email protected] ...
... Email : [email protected] Email : [email protected] ...
SEL-787 Transformer Protection Relay Data Sheet
... Software to set the user-defined curve (see Figure 4). For tripping, the relay provides a time integrating element with a settable operating characteristic. You can set the relay element to operate as an inverse-time element, a user-defined curve element, a composite element with an inverse-time cha ...
... Software to set the user-defined curve (see Figure 4). For tripping, the relay provides a time integrating element with a settable operating characteristic. You can set the relay element to operate as an inverse-time element, a user-defined curve element, a composite element with an inverse-time cha ...
TVS Diode Array SP721 Lead-Free/Green Datasheet
... ESD and over-voltage protection to sensitive input circuits. The SP721 has 2 protection SCR/Diode device structures per input. There are a total of 6 available inputs that can be used to protect up to 6 external signal or bus lines. Overvoltage protection is from the IN (Pins 1 - 3 and Pins 5 - 7) t ...
... ESD and over-voltage protection to sensitive input circuits. The SP721 has 2 protection SCR/Diode device structures per input. There are a total of 6 available inputs that can be used to protect up to 6 external signal or bus lines. Overvoltage protection is from the IN (Pins 1 - 3 and Pins 5 - 7) t ...
UCC28063A - Texas Instruments
... Optimized for consumer applications concerned with audible noise elimination, this solution extends the advantages of transition mode – high efficiency with low-cost components – to higher power ratings than previously possible. By utilizing a Natural Interleaving™ technique, both channels operate a ...
... Optimized for consumer applications concerned with audible noise elimination, this solution extends the advantages of transition mode – high efficiency with low-cost components – to higher power ratings than previously possible. By utilizing a Natural Interleaving™ technique, both channels operate a ...
HI-102 Guide for the Installation, Operation, and Maintenance of
... value shown on the nameplate. The coil insulation has been carefully selected and made with thermally upgraded materials to ensure long life at the rated temperature and 30 ambient. Overloads in excess of the rating can be tolerated if accompanied by longer periods of light loading. Severe and prol ...
... value shown on the nameplate. The coil insulation has been carefully selected and made with thermally upgraded materials to ensure long life at the rated temperature and 30 ambient. Overloads in excess of the rating can be tolerated if accompanied by longer periods of light loading. Severe and prol ...
Owner`s Manual
... consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power draw. The 1500 W inverter will operate a small microwave oven (0.2 to 3.0 cubic foot capacity) that draws ...
... consumed by the microwave oven. The microwave oven will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the oven to determine its actual power draw. The 1500 W inverter will operate a small microwave oven (0.2 to 3.0 cubic foot capacity) that draws ...
MFC190 - Algodue
... Unlike traditional current transducers, there is no danger from open-circuited secondaries. They cannot be damaged by large overloads. They are non-intrusive. They draw no power from the main circuit carrying the current to be measured. They are also light weighted and in some applications are light ...
... Unlike traditional current transducers, there is no danger from open-circuited secondaries. They cannot be damaged by large overloads. They are non-intrusive. They draw no power from the main circuit carrying the current to be measured. They are also light weighted and in some applications are light ...
Direct Electrical Heating
... (OHFWULFKHDWLQJSLSHKHDWLQJVXEVHDSRZHUV\VWHPǯRZDVVXUDQFH direct electrical heating (DEH) Products Used ANSYS® Maxwell® 15.0, ANSYS Simplorer® 10.0, ANSYS Fluent® 14, ANSYS Workbench™ 14 Description Electric heating of pipelines is attractive for long step outs, as running costs can be c ...
... (OHFWULFKHDWLQJSLSHKHDWLQJVXEVHDSRZHUV\VWHPǯRZDVVXUDQFH direct electrical heating (DEH) Products Used ANSYS® Maxwell® 15.0, ANSYS Simplorer® 10.0, ANSYS Fluent® 14, ANSYS Workbench™ 14 Description Electric heating of pipelines is attractive for long step outs, as running costs can be c ...
MAX2242EVKIT.pdf
... • One RF signal generator capable of delivering at least +10dBm of output power at the operating frequency with 802.11b comparable source • One RF power sensor capable of handling at least +20dBm of output power at the operating frequency (HP 8482A, or equivalent) • One 20dB high-power attenuator • ...
... • One RF signal generator capable of delivering at least +10dBm of output power at the operating frequency with 802.11b comparable source • One RF power sensor capable of handling at least +20dBm of output power at the operating frequency (HP 8482A, or equivalent) • One 20dB high-power attenuator • ...
An Auxillary Zero State Synthesizer to Reduce Common Mode
... century, electromagnetic disturbance sources were limited to motor-driven machinery and switching apparatus. But with the proliferation of power semiconductor technology and rapid spread of power electronic systems, interference related problems concerned with power equipment have increased signific ...
... century, electromagnetic disturbance sources were limited to motor-driven machinery and switching apparatus. But with the proliferation of power semiconductor technology and rapid spread of power electronic systems, interference related problems concerned with power equipment have increased signific ...
Reversible Current Power Supply for Fast-Field
... a field of high flux density (BD) is applied, preferably, during a short period of time. Relaxometers are usually composed by a magnet, where the sample is put, an acquisition system, that is, most of the times a Radio-Frequency system, that sends periodic pulses, and the power supply, that should b ...
... a field of high flux density (BD) is applied, preferably, during a short period of time. Relaxometers are usually composed by a magnet, where the sample is put, an acquisition system, that is, most of the times a Radio-Frequency system, that sends periodic pulses, and the power supply, that should b ...
Elgar GUPS Series 2400 VA 115/230 VAC 20.8 ARMS
... low distortion sine waveform. Protection of the critical load is maximized because it is continually supplied by the online inverter; the output is never dependent on the condition of the AC input, and there are no switching transients. Low output impedance allows driving non-linear loads that draw ...
... low distortion sine waveform. Protection of the critical load is maximized because it is continually supplied by the online inverter; the output is never dependent on the condition of the AC input, and there are no switching transients. Low output impedance allows driving non-linear loads that draw ...
70 W HID lamp ballast based on the L6569, L6385E and L6562A
... Input power, output voltage and input peak current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indirect constant power control circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Average current sense circuit . . . . . . . . . . . . . . . . ...
... Input power, output voltage and input peak current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indirect constant power control circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Average current sense circuit . . . . . . . . . . . . . . . . ...