• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
33.3 General Structure of Voltage Source Inverters
33.3 General Structure of Voltage Source Inverters

To Pot or Not Two common types of electrical testing are easily
To Pot or Not Two common types of electrical testing are easily

... Insulation testers are also known by the generic name megohmmeters.  High‐pots derive their  name from “high potential”, a reference to their test voltages, and are also dielectric breakdown testers.  Both types have two terminals by which a high voltage is applied across the test sample. Some curre ...
- Saraswathi Velu College of Engineering
- Saraswathi Velu College of Engineering

... 10. How do harmonics affect the load. The affect of harmonics on loads varies a great deal and is dependent on the load itself. Most loads are not affected by moderate levels of harmonics . Exceptions to this are loads that perform electrical measurements in the frequency domain of the harmonics. 1 ...
Simulation Using WinSPICE - West Virginia University
Simulation Using WinSPICE - West Virginia University

... • .PLOT DC V(1) V(2) (Plots the voltages at nodes 1 and 2 on the same graph. The x axis is voltage (DC sweep)) • .PLOT AC VDB(3) (Plots the decibel value of the voltage at node 3. The x axis is frequency (AC analysis)) • .PLOT TRAN I(VIN) (Plots the current through the voltage source VIN. The x axis ...
FULL TEXT - rs publication house of research and scientific journals
FULL TEXT - rs publication house of research and scientific journals

... stability depends on the solar penetration level, reactive power support and fault ride through ability. Power quality is more about consumer driven issues and dynamic performance. In this paper control strategies are proposed for STATCOM to address these issues and moreover tested in a grid connect ...
Kirchoff`s Rules
Kirchoff`s Rules

... just the motion of charged particles, the Junction Rule says simply that every charge that goes into a junction must leave it: you can’t create or destroy charges. The Loop Rule is a little more complicated, but not much: because generating a voltage in a power supply requires a power source, and dr ...
Slide 1
Slide 1

P85350
P85350

POWER QUALITY ANALYSIS BASED ON HARMONIC DISTORTION
POWER QUALITY ANALYSIS BASED ON HARMONIC DISTORTION

... Basic (Microsoft Web Developer) to display it. The results show us that all the data were satisfy with the standards. During the study period (between 12 pm until 6 pm) at the lab, there were the peak period of harmonic but from 7 pm to 7 am, the harmonics were lower than before. Its shows us that t ...
Constructional Details of transformer
Constructional Details of transformer

... higher value of leakage reactance, so that the short-circuit current, effect of mechanical force and hence the damage is less. ...
Measurement And Control Of Current/voltage Waveforms Of
Measurement And Control Of Current/voltage Waveforms Of

Control of the Shunt Active Power Filter under Non
Control of the Shunt Active Power Filter under Non

... Non-linear electrical devices have became common place in industrial and commercial facilities. Computer power supplies rectifier equipment, domestic appliances, adjustable speed drives are some examples of these non-linear loads. These non-linear power electronic loads draw non-sinusoidal currents ...
SET2011, 10th International Conference on Sustainable Energy
SET2011, 10th International Conference on Sustainable Energy

... Electrical power is currently required of our globe. Renewable energy resources will be increasingly important part in the production of electricity, in this context, Photovoltaic systems are the most resources used in the world wide (solar electric power systems has grown gradually from last (10-15 ...
scanpro20 - LaserShowParts
scanpro20 - LaserShowParts

... Wire the scan amps to the power supply, using the pinout details listed above. Before applying power, without the power connectors plugged into the scanner drivers, check for correct voltages on relevant power pins of the power connector ...
2SB817/2SD1047
2SB817/2SD1047

Distributed Generation - About the Department | University
Distributed Generation - About the Department | University

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

OPM-1038
OPM-1038

... The open fuse indicator status output acts very much like an on/off switch. With all three fuses in place and operating properly, this status output has a high resistance value of greater than ten mega-ohms. When one or more of the fuses are open, the status output becomes turned-on with a resistanc ...
Exp01v3
Exp01v3

... components across which voltage is measured. A common mistake is to connect the voltmeter in series with the circuit components. This error would add a 1M series resistance to the circuit and drastically change the circuit parameters. 2. Fluke 8010A Multimeter Operation (Ammeter - Current Measureme ...
SVC for Mitigating 50 Hz Resonance of a Long 400 kV ac
SVC for Mitigating 50 Hz Resonance of a Long 400 kV ac

... resonance occurrence presents another problem in that very little preventive solutions could be safely utilised while ensuring the reliable and continuous operation of the NamPower system. This is crucial since only the minimum amount of fixed and switched shunt reactors could be used; otherwise the ...
Advanced Common-Mode Control techniques for Low
Advanced Common-Mode Control techniques for Low

... voltage signals, which are the input of the CM sense block, are centered around VDD/2 and for very LV supply this value is lower than VT. Therefore, no CM detector circuits, where the amplifier output signals have to be connected to MOS gate terminals, can be used. A possible design solution to over ...
1 Practical Logic Characteristics
1 Practical Logic Characteristics

... the delays resulting in a change of state taking place at the output of a gate in response to a change of state applied to one of its inputs. These are measured between the 50% points on the input and output voltage waveforms. ...
high power motor test systems
high power motor test systems

... The Deviation Chart illustrates some of the different parameters affected by voltage. Note that for a +10% change in the voltage, the full load current will swing from 7% low to 11% high. All PHENIX Technologies test systems provide a continuously variable output from 0 to 100% of the rated tap volt ...
Maximum permissible loading and Static voltage stability limit of a
Maximum permissible loading and Static voltage stability limit of a

... problems that may be associated with such a stressed system is voltage instability or collapse and that causes a steady-state security problem. To operate a power system with an adequate security margin, it is essential to estimate the maximum permissible loading of the system using information abou ...
Aalborg Universitet Thøgersen, Paul Bach
Aalborg Universitet Thøgersen, Paul Bach

< 1 ... 1253 1254 1255 1256 1257 1258 1259 1260 1261 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.