introduction - KFUPM Faculty List
... mixers and vacuum cleaners) work very well on ac electricity, but very large electric motors (e.g., those which power subway trains) generally work much better on dc electricity. Let us investigate how dc electricity can be generated. ...
... mixers and vacuum cleaners) work very well on ac electricity, but very large electric motors (e.g., those which power subway trains) generally work much better on dc electricity. Let us investigate how dc electricity can be generated. ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.1, pp. 1743-1748
... processes containing voltage sensitive devices, vulnerable to degradation in the quality of power supply. The power system especially the distribution system, have numerous non linear loads which significantly affect the quality of power supply. The power quality problems occur either on source side ...
... processes containing voltage sensitive devices, vulnerable to degradation in the quality of power supply. The power system especially the distribution system, have numerous non linear loads which significantly affect the quality of power supply. The power quality problems occur either on source side ...
103_lab05
... impedance to prevent the test equipment from loading the circuit under test and thereby provide inaccurate measurements. The VOM usually has a moderately high input impedance while the DMM and oscilloscope have a high input impedance of 1M or higher. This high input impedance assures the measuremen ...
... impedance to prevent the test equipment from loading the circuit under test and thereby provide inaccurate measurements. The VOM usually has a moderately high input impedance while the DMM and oscilloscope have a high input impedance of 1M or higher. This high input impedance assures the measuremen ...
7.8.1 The parallel plate capacitor
... A capacitor is a device which is used to store electric charge. The simplest capacitor consists of two metal plates separated by an air gap. If the plates are connected to a battery, electrons are removed from one plate and moved around the circuit to the other plate. This leaves the first plate ...
... A capacitor is a device which is used to store electric charge. The simplest capacitor consists of two metal plates separated by an air gap. If the plates are connected to a battery, electrons are removed from one plate and moved around the circuit to the other plate. This leaves the first plate ...
ECE 471 Assignment 1:
... 2. Inverting Amplifier w/ resistors RA & RB input applied in series with RA ...
... 2. Inverting Amplifier w/ resistors RA & RB input applied in series with RA ...
ACCURATE DIGITAL THREE-PHASE ELECTRICITY METER AND GENERATOR Branislav Lojko
... frequency spectra. Its accuracy is better than 0.05%. The instrument can be also used as a generator of three-phase voltage and current signals with selectable phase shifts and higher harmonic components. Four main error sources in digital sampling electricity meters, namely errors of the analogue i ...
... frequency spectra. Its accuracy is better than 0.05%. The instrument can be also used as a generator of three-phase voltage and current signals with selectable phase shifts and higher harmonic components. Four main error sources in digital sampling electricity meters, namely errors of the analogue i ...
emc installation guidelines
... Following the procedures outlined will normally be required for the drive system to comply with the European regulations; some systems may require different measures. Installers must have a level of technical competence to correctly install. Although the drive unit itself does not require control of ...
... Following the procedures outlined will normally be required for the drive system to comply with the European regulations; some systems may require different measures. Installers must have a level of technical competence to correctly install. Although the drive unit itself does not require control of ...
Analysis of a New Third Harmonic Injection Active Rectifier Topology
... As can be seen from Tab.2 each three-level bridge leg mainly operates as a two-level system, the three-level operation, however, is required for smooth current control at each 60° sector transition. It is evident, that the current ratings of the NPC leg components are not ”symmetrically” (i.e., equa ...
... As can be seen from Tab.2 each three-level bridge leg mainly operates as a two-level system, the three-level operation, however, is required for smooth current control at each 60° sector transition. It is evident, that the current ratings of the NPC leg components are not ”symmetrically” (i.e., equa ...
Effects of Total Harmonic Distortion on Power System
... Harmonics, which is central focus of this study, is a specific type of disturbance that affects the quality of power, often cause by type of load attached to the power supply. It is a series of subsidiary waveforms that that accompany a primary or fundamental waveform. They result when a system prod ...
... Harmonics, which is central focus of this study, is a specific type of disturbance that affects the quality of power, often cause by type of load attached to the power supply. It is a series of subsidiary waveforms that that accompany a primary or fundamental waveform. They result when a system prod ...
Joule thief
... ultimate voltage at the collector is limited only by stray capacitances, and may rise to more than 100 times the supply voltage. For this reason, it is imperative that a load is always connected so that the transistor is not damaged. Because VCE is mirrored back to the secondary, failure of the tran ...
... ultimate voltage at the collector is limited only by stray capacitances, and may rise to more than 100 times the supply voltage. For this reason, it is imperative that a load is always connected so that the transistor is not damaged. Because VCE is mirrored back to the secondary, failure of the tran ...
New Comparators Feature Micropower Operation Under All
... Jim Williams Some micropower comparators have operating modes that allow excessive current drain. In particular, poorly designed devices can conduct large transient currents during switching. Such behavior causes dramatically increased power drain with rising frequency, or when the inputs are nearly ...
... Jim Williams Some micropower comparators have operating modes that allow excessive current drain. In particular, poorly designed devices can conduct large transient currents during switching. Such behavior causes dramatically increased power drain with rising frequency, or when the inputs are nearly ...
here - AudioFaiDaTe
... Before soldering, be sure to clean both sides the PCB with 99% isopropyl alcohol. All the parts sit on the side of the PCB with the white lettering. First solder the resistors in place, then the next tallest, and then the next tallest... If any of the parts have gold-plated leads, remove the gold fl ...
... Before soldering, be sure to clean both sides the PCB with 99% isopropyl alcohol. All the parts sit on the side of the PCB with the white lettering. First solder the resistors in place, then the next tallest, and then the next tallest... If any of the parts have gold-plated leads, remove the gold fl ...
MAX856–MAX859 3.3V/5V or Adjustable-Output, Step-Up DC-DC Converters _______________General Description
... A unique minimum-off-time, current-limited pulse-frequency modulation (PFM) control scheme is a key feature of the MAX856 series (Figure 1). This scheme combines the high output power and efficiency of a pulse-width modulation (PWM) device with the ultra-low quiescent current of a traditional PFM pu ...
... A unique minimum-off-time, current-limited pulse-frequency modulation (PFM) control scheme is a key feature of the MAX856 series (Figure 1). This scheme combines the high output power and efficiency of a pulse-width modulation (PWM) device with the ultra-low quiescent current of a traditional PFM pu ...
Print this article - International Journal of Innovative Research and
... A power optimizer is a DC to DC converter technology developed to maximize the energy harvest from solar photovoltaic or wind turbine systems. They do this by individually tuning the performance of the panel or wind turbine through maximum power point tracking, and optionally tuning the output to ma ...
... A power optimizer is a DC to DC converter technology developed to maximize the energy harvest from solar photovoltaic or wind turbine systems. They do this by individually tuning the performance of the panel or wind turbine through maximum power point tracking, and optionally tuning the output to ma ...
New ways of measuring pull-in voltage and transient
... attracted and suddenly accelerates when the pull-in voltage is reached. In contact membrane and electrode performing a coupled oscillation and the contact area gets bigger with increasing excitation voltage. When Vstim is lowered again, the membrane detaches from the electrode in a different behavio ...
... attracted and suddenly accelerates when the pull-in voltage is reached. In contact membrane and electrode performing a coupled oscillation and the contact area gets bigger with increasing excitation voltage. When Vstim is lowered again, the membrane detaches from the electrode in a different behavio ...
FXWA9306 Dual Bi-Directional I C-Bus® and SMBus Voltage- Level Translator
... As with standard I2C-bus systems, pull-up resistors are required to provide the logic HIGH levels on the translator’s bus. The FXWA9306 has a standard open2 drain configuration of the I C-bus. The size of these pullup resistors depends on the system, but each side of the translator must have a pull- ...
... As with standard I2C-bus systems, pull-up resistors are required to provide the logic HIGH levels on the translator’s bus. The FXWA9306 has a standard open2 drain configuration of the I C-bus. The size of these pullup resistors depends on the system, but each side of the translator must have a pull- ...