ECOMPACT® 23E/60E
... The compact servo drives are not intended for direct connection to the power supply system but have to be driven with an electronic converter. Connecting the motor directly to the power supply system leads to destruction of the motor. All work may only be carried out by qualified personnel. The mach ...
... The compact servo drives are not intended for direct connection to the power supply system but have to be driven with an electronic converter. Connecting the motor directly to the power supply system leads to destruction of the motor. All work may only be carried out by qualified personnel. The mach ...
1 - Cenidet
... I would like to express my sincere appreciation and gratitude to my two advisors, Dr. Hugo Calleja and Dr. Jaime Arau, for their guidance, encouragement, support and patience through the course of this work, but most of all, for their friendship. I would like to thank my committee members, Dr. Maria ...
... I would like to express my sincere appreciation and gratitude to my two advisors, Dr. Hugo Calleja and Dr. Jaime Arau, for their guidance, encouragement, support and patience through the course of this work, but most of all, for their friendship. I would like to thank my committee members, Dr. Maria ...
Old Company Name in Catalogs and Other Documents
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
Reset Generation for TI DSP Processor WP
... The voltage monitoring thresholds can be programmed into the 6-supply monitor block. The exact value of the monitoring threshold can be selected using 192 steps. The accuracy of the voltage monitoring thresholds is 0.7%. In this example, the thresholds are set to 0.9V-5%, 1.8V-5% (3 separate supplie ...
... The voltage monitoring thresholds can be programmed into the 6-supply monitor block. The exact value of the monitoring threshold can be selected using 192 steps. The accuracy of the voltage monitoring thresholds is 0.7%. In this example, the thresholds are set to 0.9V-5%, 1.8V-5% (3 separate supplie ...
Chapter 18 ELECTRIC CURRENT AND CIRCUITS
... 19. The bird perched on the power line is at the same electric potential as the line but it is isolated from the ground so that no current flows through its body. When a person standing on the ground touches a power line with a metal pole, a potential difference exists between the line and the perso ...
... 19. The bird perched on the power line is at the same electric potential as the line but it is isolated from the ground so that no current flows through its body. When a person standing on the ground touches a power line with a metal pole, a potential difference exists between the line and the perso ...
BQ2016 数据资料 dataSheet 下载
... The bq2016 sets NAC to 85% of LMD when it detects a transition from fast-charge to a trickle charge provided that 85% ≥ NAC > 80% of LMD when the bq2016 detects the transition. For this determination, fast-charge detection (FCDT) corresponds to the FCDT value set by the PROG pin. Fast-charge detecti ...
... The bq2016 sets NAC to 85% of LMD when it detects a transition from fast-charge to a trickle charge provided that 85% ≥ NAC > 80% of LMD when the bq2016 detects the transition. For this determination, fast-charge detection (FCDT) corresponds to the FCDT value set by the PROG pin. Fast-charge detecti ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
... The offsite power system is a nonsafety-related, non-class 1E system, beginning at the transmission grid and ending at the line-side terminals of the main power supply circuit breakers feeding the 13.8 kV and 6.9 kV buses, and at the terminals on the main transformer (MT) side of the generator load ...
... The offsite power system is a nonsafety-related, non-class 1E system, beginning at the transmission grid and ending at the line-side terminals of the main power supply circuit breakers feeding the 13.8 kV and 6.9 kV buses, and at the terminals on the main transformer (MT) side of the generator load ...
SKY77762 数据资料DataSheet下载
... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
DRAM pres. - cse.scu.edu
... Fetch more than a single word at each address cycle. Latch words in an output buffer. Successive requests can usually be dealt with from output buffer. ...
... Fetch more than a single word at each address cycle. Latch words in an output buffer. Successive requests can usually be dealt with from output buffer. ...
HMC985 数据资料DataSheet下载
... The chip is back-metallized and can be die mounted with AuSn eutectic preforms or with electrically conductive epoxy. The mounting surface should be clean and flat. Eutectic Die Attach: A 80/20 gold tin preform is recommended with a work surface temperature of 255 °C and a tool temperature of 265 °C ...
... The chip is back-metallized and can be die mounted with AuSn eutectic preforms or with electrically conductive epoxy. The mounting surface should be clean and flat. Eutectic Die Attach: A 80/20 gold tin preform is recommended with a work surface temperature of 255 °C and a tool temperature of 265 °C ...
Product Specification Thermal Print Head Model: MO-S2-8-5A2
... 3. If TDHC is not used, it is recommended to externally connect “Hist 1” and “Hist 2” to “Vcc” and “Hist 3” to “GND”, in order to prevent from noise- and/or crosstalk influences. ...
... 3. If TDHC is not used, it is recommended to externally connect “Hist 1” and “Hist 2” to “Vcc” and “Hist 3” to “GND”, in order to prevent from noise- and/or crosstalk influences. ...
II. proposed ELECTRONIC BALLAST
... randomly selected and measured from each manufacturer. The results obtained for the three lamp companies were basically the same, therefore, results for only one manufacturer will be shown. After the first minute the lamp resistance decreases 80% and, five minutes latter, 95%. Only after eleven minu ...
... randomly selected and measured from each manufacturer. The results obtained for the three lamp companies were basically the same, therefore, results for only one manufacturer will be shown. After the first minute the lamp resistance decreases 80% and, five minutes latter, 95%. Only after eleven minu ...
Full-Text PDF
... transistor (MOSFET) output capacitance, transformer wiring capacitance, leakage inductance at the transformer secondary side, and junction capacitance of the rectifier diodes. The conclusion drawn is that the junction capacitances of the rectifier diodes are the most influential factor. On the basis ...
... transistor (MOSFET) output capacitance, transformer wiring capacitance, leakage inductance at the transformer secondary side, and junction capacitance of the rectifier diodes. The conclusion drawn is that the junction capacitances of the rectifier diodes are the most influential factor. On the basis ...
Liebert Series 610 UPS DISCONTINUED PRODUCT
... Operation and Maintenance Manual, before as well as during performance of all maintenance procedures. Observe all battery safety precautions before working on or near the battery. This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubles ...
... Operation and Maintenance Manual, before as well as during performance of all maintenance procedures. Observe all battery safety precautions before working on or near the battery. This equipment contains several circuits that are energized with high voltage. Only test equipment designed for troubles ...
Chapter 8: Sensors & Tranducers
... principle, a motion between a conductor and magnetic field induces a voltage in the conductor (generator action). A tachometer is an inductive transducer that directly converts speed or velocity into electrical signal. ...
... principle, a motion between a conductor and magnetic field induces a voltage in the conductor (generator action). A tachometer is an inductive transducer that directly converts speed or velocity into electrical signal. ...
TMG G1492 FS2500 Track Circuit Test and Investigation Guideline
... Tuning Unit Investigation and Test .........................................................................................18 Tuning Unit Impedance Tests .................................................................................................20 End Tuning Unit Impedance Test .............. ...
... Tuning Unit Investigation and Test .........................................................................................18 Tuning Unit Impedance Tests .................................................................................................20 End Tuning Unit Impedance Test .............. ...
Optimum DC-Link Solution in HVDC Wind Park Actively
... of distributed generation and HVDC to control the voltage magnitude and reactive power flow has been studied extensively (e.g. [14], [15], [16]). By controlling the reactive power at the connection point it is possible to regulate the voltage level, given that the reactive part of the source impedan ...
... of distributed generation and HVDC to control the voltage magnitude and reactive power flow has been studied extensively (e.g. [14], [15], [16]). By controlling the reactive power at the connection point it is possible to regulate the voltage level, given that the reactive part of the source impedan ...
AN-803 APPLICATION NOTE
... “B” MSBs, respectively, with the countdown towards the A and B LSBs proceeding clockwise around the package. Figures 3, 4, and 5 show pin diagrams and package outlines; Table II and Table III list pin function descriptions for the converters. ...
... “B” MSBs, respectively, with the countdown towards the A and B LSBs proceeding clockwise around the package. Figures 3, 4, and 5 show pin diagrams and package outlines; Table II and Table III list pin function descriptions for the converters. ...
SKY77185 数据资料DataSheet下载
... high efficiencies attained throughout the entire power range, the SKY77185 delivers unsurpassed talk-time advantages. The SKY77185 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency for power output of u ...
... high efficiencies attained throughout the entire power range, the SKY77185 delivers unsurpassed talk-time advantages. The SKY77185 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency for power output of u ...
CA235001EN
... of arrester ground, secondary neutral, and transformer tank provide additional protection to distribution transformers and improve continuity of service to customers. Protective gaps provide effective and inexpensive surge protection for the primary neutral of a system (grounded only at the substati ...
... of arrester ground, secondary neutral, and transformer tank provide additional protection to distribution transformers and improve continuity of service to customers. Protective gaps provide effective and inexpensive surge protection for the primary neutral of a system (grounded only at the substati ...
ADG611 数据手册DataSheet下载
... switches. The ADG611 and ADG612 differ only in that the digital control logic is inverted. The ADG611 switches are turned on with a logic low on the appropriate control input, while a logic high is required to turn on the switches of the ADG612. The ADG613 contains two switches whose digital control ...
... switches. The ADG611 and ADG612 differ only in that the digital control logic is inverted. The ADG611 switches are turned on with a logic low on the appropriate control input, while a logic high is required to turn on the switches of the ADG612. The ADG613 contains two switches whose digital control ...
pdf - Jan Verspecht BVBA
... electrical network that behaves according to (1) and (2). This equivalent electrical network is the actual transistor model. It runs in the simulator and can be used by the designer to optimize his design. Note that, since this article is about transistor characterization, we will not further elabor ...
... electrical network that behaves according to (1) and (2). This equivalent electrical network is the actual transistor model. It runs in the simulator and can be used by the designer to optimize his design. Note that, since this article is about transistor characterization, we will not further elabor ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.