BASIC Stamp I Application Notes 1
... characters” when the transmitter is off, try grounding the metal case of the GP1U52X. It is somewhat sensitive to stray signals. If you build the transmitter and receiver on the same prototyping board for testing, you are almost certain to have this problem. Bypass all power connections with 0.1-µF ...
... characters” when the transmitter is off, try grounding the metal case of the GP1U52X. It is somewhat sensitive to stray signals. If you build the transmitter and receiver on the same prototyping board for testing, you are almost certain to have this problem. Bypass all power connections with 0.1-µF ...
Critical Design Review
... • Location requires the box to be water resistant • Ambient light reading • NOA1302 are only addressable with 1 address • Multiplexer Texas Instruments PCA9545A ...
... • Location requires the box to be water resistant • Ambient light reading • NOA1302 are only addressable with 1 address • Multiplexer Texas Instruments PCA9545A ...
Company Presentation
... neglected part of the charging system and one of the most important) – The correct cabling will be sized and routed to allow the maximum output of the alternator to be supplied to the electrical components of the vehicle and evenly transferred back to the battery for recharging. If the cables are to ...
... neglected part of the charging system and one of the most important) – The correct cabling will be sized and routed to allow the maximum output of the alternator to be supplied to the electrical components of the vehicle and evenly transferred back to the battery for recharging. If the cables are to ...
Monolithic Power Systems, Inc.
... This technology ensures the lamp will strike at any temperature and in any environment. In addition no additional components are required for varying the frequency of the lamp. ...
... This technology ensures the lamp will strike at any temperature and in any environment. In addition no additional components are required for varying the frequency of the lamp. ...
The 10th IEEE International Conference on Power Electronics and
... For realize this results we suppose a motor control has available flux-weakening operation. In Figure 6 can be shown these known current and voltage vectors, setting by torque angle. We have done several simulations by Infolytica based FEA for investigate some main characteristics of this PMSM in th ...
... For realize this results we suppose a motor control has available flux-weakening operation. In Figure 6 can be shown these known current and voltage vectors, setting by torque angle. We have done several simulations by Infolytica based FEA for investigate some main characteristics of this PMSM in th ...
Power Factor Correction Regulator BLR-CX 6 to 14 steps
... BLR-CX can be active. The countdown can be interrupted by pushing (esc) button, in this case also the discharging time blockade starts before the regulation starts with the preset parameters. BLR-CX is not preset: During the countdown is running, automatic initialisation of BLR-CX can be started by ...
... BLR-CX can be active. The countdown can be interrupted by pushing (esc) button, in this case also the discharging time blockade starts before the regulation starts with the preset parameters. BLR-CX is not preset: During the countdown is running, automatic initialisation of BLR-CX can be started by ...
Joint meeting Next meeting reminder, March 2012 Minutes
... Steve then looked at fire risks from using electrical equipment such as welders where overheating can cause arching or sparking with the potential to ignite any dusts, or vapours of ethanol or hydrogen gas etc... in the vicinity, in some cases leading to explosions. He explained that arcs can be ge ...
... Steve then looked at fire risks from using electrical equipment such as welders where overheating can cause arching or sparking with the potential to ignite any dusts, or vapours of ethanol or hydrogen gas etc... in the vicinity, in some cases leading to explosions. He explained that arcs can be ge ...
800-75 300 A Externally Operated Series Multiple (Dual Voltage
... manual internal tap changing of distribution transformers because line crews need not be exposed to highvoltage conductors and hot transformer fluid. They also eliminate the need to dismount pole-type transformers for voltage adjustment and prevent exposure of the transformer tank interiors to con ...
... manual internal tap changing of distribution transformers because line crews need not be exposed to highvoltage conductors and hot transformer fluid. They also eliminate the need to dismount pole-type transformers for voltage adjustment and prevent exposure of the transformer tank interiors to con ...
awa_14-7490
... section is enclosed in a brass box, heavily tin-plated, and all leads entering the box are well filtered, variable condenser rotor and stator are milled from solid brass, and are insulated by polystyrene and micalex respectively. The r-f voltage developed is monitored by a diode voltmeter, and may b ...
... section is enclosed in a brass box, heavily tin-plated, and all leads entering the box are well filtered, variable condenser rotor and stator are milled from solid brass, and are insulated by polystyrene and micalex respectively. The r-f voltage developed is monitored by a diode voltmeter, and may b ...
AN1208: LCD screens don`t flicker - or do they
... driver. The ISL45041/2 is a current output, non-volatile DCP that can operate with an AVDD of up to 20V. The ISL45041/2 uses a two-wire, up and down interface. It is an extremely accurate 7-bit device with a resolution of 128 steps. The desired Vcom value can be stored in an on-board EEPROM. The dig ...
... driver. The ISL45041/2 is a current output, non-volatile DCP that can operate with an AVDD of up to 20V. The ISL45041/2 uses a two-wire, up and down interface. It is an extremely accurate 7-bit device with a resolution of 128 steps. The desired Vcom value can be stored in an on-board EEPROM. The dig ...
HVDC Technology Line Commutated Converters
... • MRTB – metallic return transfer breaker, used for switching from ground return to metallic return • GRTS – ground return transfer switch, used for switching from metallic return to earth return in preparation for restarting pole (NRTS for systems with continuous metallic neutral) • BPS – bypass s ...
... • MRTB – metallic return transfer breaker, used for switching from ground return to metallic return • GRTS – ground return transfer switch, used for switching from metallic return to earth return in preparation for restarting pole (NRTS for systems with continuous metallic neutral) • BPS – bypass s ...
ADF7023-J (Rev. 0)
... The RC oscillator can be used to control the wake-up timing of the ADF7023-J low power modes. Its typical accuracy is specified as 1.5% after a calibrat ion at 25°C. The calibration range of the RC oscillator is not sufficient to ensure a 1.5% typical accuracy on all devices. This can result in the ...
... The RC oscillator can be used to control the wake-up timing of the ADF7023-J low power modes. Its typical accuracy is specified as 1.5% after a calibrat ion at 25°C. The calibration range of the RC oscillator is not sufficient to ensure a 1.5% typical accuracy on all devices. This can result in the ...
RF2044A
... current into this pin to a desired level. The resistor value is determined by the following equation: ...
... current into this pin to a desired level. The resistor value is determined by the following equation: ...
Exam Solutions
... (21 pts) Z-bus: A three-bus network is operating so that all buses have voltage magnitudes equal to 1.0 pu. Each bus is connected to the other two buses via branches having impedance of j0.1 pu. The Z-bus of the network is given as: ...
... (21 pts) Z-bus: A three-bus network is operating so that all buses have voltage magnitudes equal to 1.0 pu. Each bus is connected to the other two buses via branches having impedance of j0.1 pu. The Z-bus of the network is given as: ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.