• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Negative-Sequence Impedance Directional Element
Negative-Sequence Impedance Directional Element

... V2 = 10<180 volts I2 = 3<-90 amps T32Q = |V2| · |I2| · cos (<-V2 - (
optimal location of voltage regulators in radial distribution
optimal location of voltage regulators in radial distribution

... Minimal and maximal voltage values for each regulator : Weighting coefficient ...
A Survey on Instrumentation Amplifiers used for Biomedical
A Survey on Instrumentation Amplifiers used for Biomedical

... conditioning block at the front end for the amplification of bio signals [1]. The instrumentation amplifier can be defined as precision closed loop gain block that has a pair of differential input terminals and a single ended output that works with respect to a common or a reference terminal. An in- ...
Morini Riders Club - elctrical system
Morini Riders Club - elctrical system

... The electrical system is divided into two separate parts: the charging circuit and the ignition circuit. ...
Mechanical Load Fault Detection in Induction
Mechanical Load Fault Detection in Induction

... MMFs. The equivalent magnetic flux in one phase is obtained by integration of the magnetic field in each turn of the phase winding. The induced phase voltage, related to the current by the stator voltage equation, is then deduced from the magnetic flux. This method has been used by the authors in [8 ...
File
File

... the magnetic field is completely contained with the material probably has limited use. However, it is important to understand that the magnetic field can flow in loop within a material. (See section on circular magnetism for more information). ...
Organic fouling properties of anion-exchange membranes - J
Organic fouling properties of anion-exchange membranes - J

Design, Construction and Characterization of a Line-Type
Design, Construction and Characterization of a Line-Type

Audio Mixer (2016) project document
Audio Mixer (2016) project document

50a62-820 white-rodgers
50a62-820 white-rodgers

... ignitor is turned off, and the 50A62 control goes into the “retry” sequence. The “retry” sequence provides a 15second wait following an unsuccessful ignition attempt (flame not detected). After this wait, the ignition sequence is restarted. If this ignition attempt is unsuccessful, one more retry wi ...
Series and Parallel Circuits - cK-12
Series and Parallel Circuits - cK-12

Circuit Note CN-0150
Circuit Note CN-0150

... and external ADC voltage references. The charts show improved system performance and lower temperature drift with the use of a low drift external ADC voltage reference. (See the Common Variations section for more details about the use of an external reference. A complete design support package for t ...
TransTube®
TransTube®

... The uncertainty re: U.S. tube manufacturers and the fact that tubes themselves were becoming poorer in quality and much higher in price led me to conclude that we needed to began a major research project to figure out how to make solid-state devices perform, sound, and “feel” like tubes. Hopefully, ...
600W~3000W
600W~3000W

... (a) 120V models: The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation. This conforms to National Electrical Code requirements that separately derived AC sources (such as inverter and generators) have their neutral co ...
MAX11205 16-Bit, Single-Channel, Ultra-Low Power, Delta-Sigma ADC with 2-Wire Serial Interface General Description
MAX11205 16-Bit, Single-Channel, Ultra-Low Power, Delta-Sigma ADC with 2-Wire Serial Interface General Description

... Delta-Sigma ADC with 2-Wire Serial Interface The MAX11205 is an ultra-low power (< 240FA active), high-resolution, low-speed, serial-output ADC. This device provides the highest resolution per unit power in the industry, and is optimized for applications that require very high dynamic range with low ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... fractionally multiply or scale the voltages such as (3/2, 4/3, 2/3, etc.) and generate arbitrary voltages by quickly alternating between modes depending on the circuit topology. But when charge pump is used in PLL then it can supply positive and negative current pulses into loop filter of PLL. But i ...
Sendyne Corp. Impact of Current Measurement Offset Error in SOC
Sendyne Corp. Impact of Current Measurement Offset Error in SOC

... on Coulomb counting through the current measurement system to determine SOC. Besides gain error, offset error of the current measurement system has a significant impact on the accuracy of the SOC estimation. Offset error is the erroneous value of current read by the measurement system when the actua ...
Owner`s Guide for the SVP-1500 Rack Mount Bass Power
Owner`s Guide for the SVP-1500 Rack Mount Bass Power

... All Ampeg products are designed for continuous safe operation, as long as common sense is used and steps are taken to help avoid certain problems. Abiding by the following rules can help prevent damage to your amplifier, yourself and others. • The amplifier is equipped with a three-pronged AC power ...
MTW10N100E Power MOSFET 10 Amps, 1000 Volts
MTW10N100E Power MOSFET 10 Amps, 1000 Volts

A new Circuit for Low-Cost Electronic Ballast Passive Valley Fill with
A new Circuit for Low-Cost Electronic Ballast Passive Valley Fill with

... The ballast will use Passive Valley Fill configuration to reduce costs compared to standard PFC. To overcome the disadvantage of the very high current crest factor, additional circuit has been used to modulate the Half Bridge frequency versus the bus voltage. The system will work at a minimum freque ...
Basic Physics of Semiconductors
Basic Physics of Semiconductors

Day 2 Notes 1
Day 2 Notes 1

V430-J-RA22 - Unitronics
V430-J-RA22 - Unitronics

... In addition, according to jumper settings and appropriate wiring: - Inputs 5 and 6 can function as either digital or analog inputs. - Input 0 can function as high-speed counter, as part of a shaft-encoder, or as normal digital input. - Input 1 can function as either counter reset, as part of a shaft ...
9130B Series Triple Output Power Supply
9130B Series Triple Output Power Supply

MyM-3S Installation Guide
MyM-3S Installation Guide

... 6 Installation and configuration The MyM-3S can be installed either as a stand alone unit directly on the wall or by the use of a dedicated MyM Security Wall Mount (part number 702800.10). The MyM Security Wall Mount secures both the MyM and CAM-modules with a locking function to avoid loss of CAM’ ...
< 1 ... 324 325 326 327 328 329 330 331 332 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.