1902 mkIV - Cambridge Electronic Design
... channel number dropdown lists. These identify the com port being used, and the channel number to which the 1902 is set. As soon as they correspond to the 1902 present, it will be identified and reported. In multiple installations, where all 1902s share the same com port, the 1902 identified will cha ...
... channel number dropdown lists. These identify the com port being used, and the channel number to which the 1902 is set. As soon as they correspond to the 1902 present, it will be identified and reported. In multiple installations, where all 1902s share the same com port, the 1902 identified will cha ...
Content
... This document provides a policy for the neutral earthing of systems to be employed in Eskom Distribution’s HV, MV and LV networks. It further describes the policy with regard to the earthing of the neutral points of specific equipment: power transformers and capacitor banks. The earthing of Single W ...
... This document provides a policy for the neutral earthing of systems to be employed in Eskom Distribution’s HV, MV and LV networks. It further describes the policy with regard to the earthing of the neutral points of specific equipment: power transformers and capacitor banks. The earthing of Single W ...
ea y - Moeller Benelux
... • The lighting can be switched On and Off centrally or remotely using an impulse relay function. • The timer-controlled Off pulse enables the lighting to be switched off centrally for energy saving. • A base unit controls up to 12 independent lighting groups. Purpose-dedicated lighting control, such ...
... • The lighting can be switched On and Off centrally or remotely using an impulse relay function. • The timer-controlled Off pulse enables the lighting to be switched off centrally for energy saving. • A base unit controls up to 12 independent lighting groups. Purpose-dedicated lighting control, such ...
OPERATION MANUAL for HWP-50E Hot Wire Process IMPORTANT
... wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. ...
... wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet. ...
Operation Manual
... diagnostics. It also provides extensive monitoring and control through a menu of software commands and alarms providing access to the numerous operating parameters and features available in the unit. Access to features and M&C is provided via several methods including: Hand held terminal, RS232, RS4 ...
... diagnostics. It also provides extensive monitoring and control through a menu of software commands and alarms providing access to the numerous operating parameters and features available in the unit. Access to features and M&C is provided via several methods including: Hand held terminal, RS232, RS4 ...
MS2000 Operation Manual
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment g ...
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment g ...
10-1000 kW Operation
... (1) Press the generator set off/reset button to shut down the generator set. (2) Disconnect the power to the battery charger, if equipped. (3) Remove the battery cables, negative (--) lead first. Reconnect the negative (--) lead last when reconnecting the battery. Follow these precautions to prevent ...
... (1) Press the generator set off/reset button to shut down the generator set. (2) Disconnect the power to the battery charger, if equipped. (3) Remove the battery cables, negative (--) lead first. Reconnect the negative (--) lead last when reconnecting the battery. Follow these precautions to prevent ...
NAVSEA TE000-AB-GTP-010 Rev 1 With Change A Parts Derating
... Many equipment item failures are precipitated by stress. When applied stress exceeds the inherent strength of the part, either a serious parametric degradation or a failure will occur. To assure reliability, equipment must be designed to endure stress over time without failure. Parameters which stre ...
... Many equipment item failures are precipitated by stress. When applied stress exceeds the inherent strength of the part, either a serious parametric degradation or a failure will occur. To assure reliability, equipment must be designed to endure stress over time without failure. Parameters which stre ...
DXTN07100BP5 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Fluke Corporation Fluke 83V Industrial Multimeter Manual
... Specifications are subject to change without notice. All product names are trademarks of their respective companies. ...
... Specifications are subject to change without notice. All product names are trademarks of their respective companies. ...
The Electricity at Work Regulations 1989. Guidance on
... within their control (see regulation 3). 19 Self-contained portable systems, such as portable generating sets, are electrical systems for the purpose of the Regulations, as are transportable systems and systems on vehicles etc. Electrical equipment 20 ‘Electrical equipment’ as defined in the Regul ...
... within their control (see regulation 3). 19 Self-contained portable systems, such as portable generating sets, are electrical systems for the purpose of the Regulations, as are transportable systems and systems on vehicles etc. Electrical equipment 20 ‘Electrical equipment’ as defined in the Regul ...
Frequency Input Alarm Trips, Factory Ranged API 1700 G, API 1720 G
... Adjust the setpoint control to the point at which the relay changes state from a non-alarm to an alarm condition. If a larger amount of deadband is desired turn the deadband potentiometer clockwise. The deadband is symmetrical about the setpoint; both transition points will change as deadband is inc ...
... Adjust the setpoint control to the point at which the relay changes state from a non-alarm to an alarm condition. If a larger amount of deadband is desired turn the deadband potentiometer clockwise. The deadband is symmetrical about the setpoint; both transition points will change as deadband is inc ...
Repetitive Avalanche of Automotive MOSFETs
... As a second example the EPS system might be considered. Whereas in the past just six MOSFETs were used for the B6-bridge, today up to 11 MOSFETs are considered. There is one safety switch combining the function of reverse polarity protection and an additional device for turn off in case of a mal-fun ...
... As a second example the EPS system might be considered. Whereas in the past just six MOSFETs were used for the B6-bridge, today up to 11 MOSFETs are considered. There is one safety switch combining the function of reverse polarity protection and an additional device for turn off in case of a mal-fun ...
NVT2001, NVT2002 - NXP Semiconductors
... 1.0 V and 5 V without the need for a direction pin in open-drain or push-pull applications. Bit widths ranging from 1-bit or 2-bit are offered for level translation application with transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or ...
... 1.0 V and 5 V without the need for a direction pin in open-drain or push-pull applications. Bit widths ranging from 1-bit or 2-bit are offered for level translation application with transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.