MAX1426 10-Bit, 10Msps ADC General Description Features
... for excellent dynamic performance; at the same time, it minimizes the number of external components. Low input capacitance of only 8pF minimizes input drive requirements. A wide input bandwidth (up to 150MHz) makes this device suitable for digital RF/IF downconverter applications employing undersamp ...
... for excellent dynamic performance; at the same time, it minimizes the number of external components. Low input capacitance of only 8pF minimizes input drive requirements. A wide input bandwidth (up to 150MHz) makes this device suitable for digital RF/IF downconverter applications employing undersamp ...
Eaton 9155 and 9355 UPS
... 0,99 input power factor and less than 4,5% ITHD, thus eliminating interference with other critical equipment in the same electrical network and enhancing compatibility with generators. ...
... 0,99 input power factor and less than 4,5% ITHD, thus eliminating interference with other critical equipment in the same electrical network and enhancing compatibility with generators. ...
isobar® - Parts Express
... When choosing a line conditioner, make sure that the wattage of the connected equipment doesn't exceed the rated wattage of the unit. Simply add up the watt ratings on the back panel of each piece of equipment and size your line conditioner accordingly. If your units are rated in amps, simply multip ...
... When choosing a line conditioner, make sure that the wattage of the connected equipment doesn't exceed the rated wattage of the unit. Simply add up the watt ratings on the back panel of each piece of equipment and size your line conditioner accordingly. If your units are rated in amps, simply multip ...
Episode 122 - Teaching Advanced Physics
... For an oscilloscope deflection is proportional to potential difference, and the CRO has high resistance, so it has all the properties of an ideal voltmeter. Unlike most voltmeters, many commercial CROs have one side of each input is earthed. This does not normally matter, but if the CRO is being use ...
... For an oscilloscope deflection is proportional to potential difference, and the CRO has high resistance, so it has all the properties of an ideal voltmeter. Unlike most voltmeters, many commercial CROs have one side of each input is earthed. This does not normally matter, but if the CRO is being use ...
Analog Motion Sensors - METU | Department of Mechanical
... Ab l t position iti over one revolution – Some signal processing is needed. needed ...
... Ab l t position iti over one revolution – Some signal processing is needed. needed ...
Understanding and using LLC Converters to Great
... stage. We do not gain by simply shifting the cost and dissipation, from one circuit block to another: the EMI stage in this case. Question 2: The simplest, seemingly most obvious, question can in fact become the hardest to answer: how do we “regulate” the output voltage (of a resonant converter)? Do ...
... stage. We do not gain by simply shifting the cost and dissipation, from one circuit block to another: the EMI stage in this case. Question 2: The simplest, seemingly most obvious, question can in fact become the hardest to answer: how do we “regulate” the output voltage (of a resonant converter)? Do ...
FDD6680AS 30V N-Channel PowerTrench SyncFET
... Thermal characterization performed using the conditions described in Note 1b. Transient thermal response will change depending on the circuit board design. ...
... Thermal characterization performed using the conditions described in Note 1b. Transient thermal response will change depending on the circuit board design. ...
Emergency Voltage Stability Controls: An Overview
... decision-based SPS relies on a more involved analysis of a model of the system; • closed-loop vs. open-loop. An SPS works in closedloop when it is able to act several times, each action relying on the measured result of the previously taken actions. Decentralized SPS are more reliable, since they do ...
... decision-based SPS relies on a more involved analysis of a model of the system; • closed-loop vs. open-loop. An SPS works in closedloop when it is able to act several times, each action relying on the measured result of the previously taken actions. Decentralized SPS are more reliable, since they do ...
Linear Circuit Experiment MAE 171a
... Background on Op-Amps An operational amplifier (op-amp) is a direct current (DC) coupled high-gain electronic voltage amplifier with differential inputs and typically a single output. In most situations the output of the op-amp is controlled either by negative feedback, which largely determines the ...
... Background on Op-Amps An operational amplifier (op-amp) is a direct current (DC) coupled high-gain electronic voltage amplifier with differential inputs and typically a single output. In most situations the output of the op-amp is controlled either by negative feedback, which largely determines the ...
feb_2011_RF_amplifier_report - Indico
... • Coax system will use large phase shifter to make amplifier immune to reflected power issues • Hybrid power splitters to divide power before each cavity with a rejection load, this should provide a robust reliable system • Local phase shifters in each cavity coupler, small range available only, so ...
... • Coax system will use large phase shifter to make amplifier immune to reflected power issues • Hybrid power splitters to divide power before each cavity with a rejection load, this should provide a robust reliable system • Local phase shifters in each cavity coupler, small range available only, so ...
Seminar Report
... connected between the rotor side and the grid side can make the rotor flux rotate from a sub-synchronous speed to a super-synchronous speed. The DFIG can produce and inject constant-frequency power to the grid by controlling the rotor flux. The power converter only needs to handle a fraction (typica ...
... connected between the rotor side and the grid side can make the rotor flux rotate from a sub-synchronous speed to a super-synchronous speed. The DFIG can produce and inject constant-frequency power to the grid by controlling the rotor flux. The power converter only needs to handle a fraction (typica ...
XAPP946 - 适用于 Virtex-4 RocketIO MGT 的开关电源
... used, linear regulator presents a considerable thermal management design challenge. One solution to this problem uses a switching regulator. The switching regulator can easily achieve greater than 85% efficiency and often can peak near 95%. The switching regulator frees board designers to use any in ...
... used, linear regulator presents a considerable thermal management design challenge. One solution to this problem uses a switching regulator. The switching regulator can easily achieve greater than 85% efficiency and often can peak near 95%. The switching regulator frees board designers to use any in ...
ENHANCEMENT OF TRANSIENT STABILITY FOR AN AC/DC
... can control the output of active power and reactive power independently. It is the major difference from line commutated HVDC transmission system. In AC/DC interconnected transmission system, the rotor angle stability of power systems can be improved by the control of active power. The AC voltage in ...
... can control the output of active power and reactive power independently. It is the major difference from line commutated HVDC transmission system. In AC/DC interconnected transmission system, the rotor angle stability of power systems can be improved by the control of active power. The AC voltage in ...
Main Linac Working Group
... • A prototype power supply for S1-Global is under construction and will be completed in October. • The first PS system for DRFS will be evaluated in S1-Global test. ...
... • A prototype power supply for S1-Global is under construction and will be completed in October. • The first PS system for DRFS will be evaluated in S1-Global test. ...
Falcon F45 Series Digital Panel Meter AC/TRMS Current
... desired value is displayed. To decrease a displayed value, momentarily place jumper across “DOWN” pins C and 4. After the desired numeric value is obtained, remove the jumper and momentarily place it across the “ENTER” pins C and 1. This will store the value in memory and move on to the next paramet ...
... desired value is displayed. To decrease a displayed value, momentarily place jumper across “DOWN” pins C and 4. After the desired numeric value is obtained, remove the jumper and momentarily place it across the “ENTER” pins C and 1. This will store the value in memory and move on to the next paramet ...
LT6604-5
... Gain and phase are well matched between the two channels. Gain for each channel is independently programmed using two external resistors. The LT6604-5 enables level shifting by providing an adjustable output common mode voltage, making it ideal for directly interfacing to ADCs. The LT6604-5 is fully ...
... Gain and phase are well matched between the two channels. Gain for each channel is independently programmed using two external resistors. The LT6604-5 enables level shifting by providing an adjustable output common mode voltage, making it ideal for directly interfacing to ADCs. The LT6604-5 is fully ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.