• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Embedded Generation - Technical Access Standards
Embedded Generation - Technical Access Standards

... Network (JEN). The document is intended to assist proponents or their agents in understanding JEN’s access requirements and form a framework for negotiations on technical issues. JEN recommends that this document be reviewed by the proponent in conjunction with the following: 1. Embedded Generation ...
DC fans - specials - ebm
DC fans - specials - ebm

... form of an exposed wire that can be placed anywhere, or an internal sensor located directly in the fan hub in the air flow provides continuous and undissipated thermal information to the control electronics for speed adjustment. A range of temperature sensors can be found on page 178. ...
Using BLDC motors in small home appliances
Using BLDC motors in small home appliances

... helps to lengthen battery life. ...
Physics - Calderglen High School
Physics - Calderglen High School

... The distance she has travelled is 3 km + 4 km = 7 km Her displacement is from A to C. This can be measured on the diagram as 5 cm, then converted using the scale to 5 km. The angle BAC is measured to find the direction of her final displacement. It is 53˚ Displacement = 5 km at a bearing of (053). ...
Recovery of dielelectric strength of expulsion fuses after arc current
Recovery of dielelectric strength of expulsion fuses after arc current

... region over arc energy of about 0.5 kJ. Fig.9 shows the regions of observed post-arc current. The experiments were undertaken for three cases of arc energy in the gas-evolving tube of inner diameter of 6 mm and length of 15 cm and arc current at arc initiation of 1.0 kA. No post-arc current flows wi ...
B. Transient Protection Modules
B. Transient Protection Modules

Aalborg Universitet Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems
Aalborg Universitet Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems

W.S. Chang, T.A. Parlikar, M.D. Seeman, D.J. Perreault, J.G. Kassakian, and T.A. Keim, “A New Electromagnetic Valve Actuator,” 2002 IEEE Workshop on Power Electronics in Transportation, Auburn Hills, MI, October 2002, pp. 109-118.
W.S. Chang, T.A. Parlikar, M.D. Seeman, D.J. Perreault, J.G. Kassakian, and T.A. Keim, “A New Electromagnetic Valve Actuator,” 2002 IEEE Workshop on Power Electronics in Transportation, Auburn Hills, MI, October 2002, pp. 109-118.

... is regenerated continuously. A spring is used to store the initial required energy and then the energy is transferred cyclically to the engine valve and cam. To be a competitive technology, any variable valve actuation system must be able to provide this large inertial power economically [4], [8]. S ...
FJD5555 NPN Silicon Transistor — NPN Silicon T ransistor
FJD5555 NPN Silicon Transistor — NPN Silicon T ransistor

... system whose failure to perform can be reasonably expected to intended for surgical implant into the body or (b) support or sustain cause the failure of the life support device or system, or to affect its life, and (c) whose failure to perform when properly used in safety or effectiveness. accordanc ...
STP 3 & 4 2.0  Design Certification ITAAC
STP 3 & 4 2.0 Design Certification ITAAC

... 1E DC division vital AC power. In the EMS For the ECFs, independence is provided between Class 1E divisions, and between Class 1E divisions and non-Class 1E equipment. Tests will be performed on EMS equipment implementing the ECFs by providing a test signal in only one Class 1E division at a time. b ...
transparencies
transparencies

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

X WRITE REGULATED POWER SUPLY
X WRITE REGULATED POWER SUPLY

... tion are difficult to operate in two directions, and careful that, in combination with the inductances of the lines, control of the current level is particularly troublesome they provide the correct :time constant for appropriate under these conditions. As an alternative, separate rise time of the c ...
Touch and Remote Control Intelligent Safety Dimmer - TLC
Touch and Remote Control Intelligent Safety Dimmer - TLC

Progress in high-power high-efficiency VCSEL arrays [7229-2]
Progress in high-power high-efficiency VCSEL arrays [7229-2]

... fabricated in very compact modules as part of RGB sources for micro-projectors for example 7. Diode pumped green lasers are also used in many other applications such as scientific instruments (interferometers), precision machining, targeting in defense applications, and for fluorescence diagnostics ...
MP3450 R2 User Guide
MP3450 R2 User Guide

... 1. Connect the adapter plug into the power jack on the portable device. The voltage selection will be locked automatically and cannot be changed until the power output cord is disconnected from the device. 2. Turn on the portable device and use it as you would normally. While connected, myPower ALL ...
Electronic Devices and Circuits
Electronic Devices and Circuits

Heathkit V-7A - Orange County (California) Amateur Radio Club
Heathkit V-7A - Orange County (California) Amateur Radio Club

... It was supposed to be a battery operated version of the V-2 VTVM, and set to sell for $34.50. But due to engineer problems, probably related to battery cost and life, very few, if any, were manufactured commercially. Prototypes are evidently around. The Heathkit V-4 VTVM: The V-4 came out in 1950 co ...
NGG NGB Circuit Breakers File size 1.1MB
NGG NGB Circuit Breakers File size 1.1MB

P 3 Owner`s Guide
P 3 Owner`s Guide

... • One pair of balanced interconnect cables with XLR connectors • An audio source component with balanced output connectors ...
doc 90018-031 - Metrix-Vibration Monitoring Solutions
doc 90018-031 - Metrix-Vibration Monitoring Solutions

... machine is to the process or how expensive it is), one on each end of the motor and one on each end of the compressor, fan, pump or whatever is being driven. If there is a gear box in between, one may be used here also. It is quite common to use only one switch. In this case, it is best to mount on ...
Data sheet NRS 2-50, 2-51
Data sheet NRS 2-50, 2-51

... within this measuring range. During normal operation the actual value is indicated on the seven-segment LED display. When the MIN or MAX water level is reached, the MIN or MAX output contact is switched over after the de-energizing delay and the MIN or MAX LED is illuminated . The level switch NRS 2 ...
Vecto II - CT LAB Power Quality
Vecto II - CT LAB Power Quality

...  Class A performance over all of the input range inclusive of 63.5 V (if LN measurements are done in a 110 V line-line VT circuit)  6 terminals are used for 4 voltage input channels with maximum input ratings of 600 V. o The first 4 terminals connect 3 different phase voltages such as in a 3-phase ...
Industrial IGBT Modules Explanation of Technical Information
Industrial IGBT Modules Explanation of Technical Information

... target datasheets are useful for the initial calculations and approximations. The information and values of a target datasheet cannot be guaranteed for the final product. The dimensioning of an inverter should only be done with values based on a preliminary or final datasheet. During the development ...
Evolution of Polymorphic Self-Checking Circuits
Evolution of Polymorphic Self-Checking Circuits

< 1 ... 167 168 169 170 171 172 173 174 175 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report