• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX196,198 - Part Number Search
MAX196,198 - Part Number Search

S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators
S.T.A.R. PATHFINDER variable trip test point faulted circuit indicators

FRENIC-EcoPAK NonBypass EngSpec_FECA-TE-103E
FRENIC-EcoPAK NonBypass EngSpec_FECA-TE-103E

VLT 3500 Series
VLT 3500 Series

section 16
section 16

... K. VFD shall include two 0-10 VDC or 4-20 mA analog output for monitoring, or "speed tracking" the VFD. The analog output signal will be proportional to output frequency, output current, output power, PI (Proportional & Integral control) feedback or DC bus voltage. L. VFD shall provide terminals for ...
BU21025GUL
BU21025GUL

... BU21025GUL will be in the state that can not be transfer and received data. Data Transfer Data is transferred with the most significant bit (MSB) first and 8-bits long. Each byte has to be followed by an acknowledge bit. A Timing of SDA data receiving is rising edge of SCL. A state of SDA can only c ...
The key to unlocking your efficiency potential
The key to unlocking your efficiency potential

... ...with the VLT® Midi Drive FC 280, the evolution of the popular VLT® 2800 drive. Unlock savings, with a wide range of features designed to make installing, using and maintaining the drive as simple and as easy as possible – just set it and forget it. For precise and efficient motor control for machin ...
The Evaluation of Steel Conduit and EMT as Equipment
The Evaluation of Steel Conduit and EMT as Equipment

... equipment and wiring and other electrically conductive material likely to become energized shall be installed in a manner that creates a low-impedance circuit facilitating the operation of the overcurrent device or ground detector for high-impedance grounded systems.” • “It shall be capable of safel ...
Boom Harder! - TuningMania.com.br
Boom Harder! - TuningMania.com.br

... The fuses that are supplied with the amplifier are there to protect the amplifier from overload conditions and to protect your car from an electrical fire should a major short circuit occur. Never bypass the fuse! Installation of larger than recommended fuses will void your warranty. Under very extr ...
MAX1270/MAX1271 Multirange, +5V, 8-Channel, Serial 12-Bit ADCs General Description
MAX1270/MAX1271 Multirange, +5V, 8-Channel, Serial 12-Bit ADCs General Description

... ±15V powered sensors directly to a single +5V system. In addition, these converters are fault protected to ±16.5V; a fault condition on any channel will not affect the conversion result of the selected channel. Other features include a 5MHz bandwidth track/hold, softwareselectable internal/external ...
ZXRE060 0.6V ADJUSTABLE PRECISION SHUNT REGULATOR
ZXRE060 0.6V ADJUSTABLE PRECISION SHUNT REGULATOR

... 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in ...
Complete 14-Bit CCD/CIS Signal Processor AD9822
Complete 14-Bit CCD/CIS Signal Processor AD9822

... The rms output noise is measured using histogram techniques. The ADC output codes’ standard deviation is calculated in LSB and converted to an equivalent voltage, using the relationship 1 LSB = 4 V/16384 = 244 mV. The noise is then referred to the input of the AD9822 by dividing by the PGA gain. Cha ...
TRANSISTOR
TRANSISTOR

... CONFIGURATIONS AS AMPLIFIER Each configuration, as you will see later, has particular characteristics that make it suitable for specific applications. An easy way to identify a specific transistor configuration is to follow three simple steps: 1- Identify the element (emitter, base, or collector) t ...
http://www.utdallas.edu/~tres/papers/thompson.etal.1994.pdf
http://www.utdallas.edu/~tres/papers/thompson.etal.1994.pdf

... signals provided by TI'L pulses generated at the digital output ports of an analog-to-digital (A/D) converter. An electronic circuit is described that provides stable inputs to the A / D converter, transducing eyeblink responses to voltage signals opto-electronically, without requiring any invasive ...
273 Branchport Avenue Long Branch, N.J.
273 Branchport Avenue Long Branch, N.J.

Cashpower GEM Lite
Cashpower GEM Lite

... The meter has specifically been developed to provide utilities with a quality, low cost, highly reliable STS keypad prepayment metering solution, while maintaining conformance to internationally standards such as IEC62055-31. ...
Voltage recovery after unbalanced and balanced voltage dips in
Voltage recovery after unbalanced and balanced voltage dips in

... voltages [1], [2]. Voltage dips are due to short-duration increases in current elsewhere in the power system. The main causes of voltage dips are faults, motor starting, and transformer energizing. A voltage dip at the terminals of equipment may lead to maloperation of the equipment. Most maloperati ...
Lightning and surge protection for free field PV power plants
Lightning and surge protection for free field PV power plants

... array and the operations building. To permanently keep the earth resistance stable over the many years of operation of a PV power plant, the influences of corrosion, soil moisture and frost must be taken into account. Only the areas below the frost line must be considered for the effective earth ele ...
Multi objective Flower Pollination Algorithm for solving capacitor
Multi objective Flower Pollination Algorithm for solving capacitor

... Mesut E. Baran, and Felix F. Wu [1], considered the capacitor placement in the radial distribution system. Their objective of the work was to find the best capacitor location and size of the capacitor in the radial system. They used mixed integer technique for the problem solving. They decomposed th ...
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A
300 Watt Pure Sine Wave DC-AC Inverter PST-30S-12A PST-30S-24A

part 1 general - Rockwell Automation
part 1 general - Rockwell Automation

... NOTICE: The specification guidelines shown in this document are intended to aid in the specification of products. Specific installations have specific requirements, and Rockwell Automation does not recommend or intend any specific application based solely upon the guidelines provided here. Because o ...
115C and 117C
115C and 117C

... Use proper protective equipment, as required by local or national authorities when working in hazardous areas. Avoid working alone. Use only the replacement fuse specified or the protection may be impaired. Check the test leads for continuity before use. Do not use if the readings are high or noisy. ...
Evaluates: MAX4952A Evaluation Kit General Description Features
Evaluates: MAX4952A Evaluation Kit General Description Features

... The application circuit provides the means for evaluating the MAX4952A in a SAS/SATA application. This section of the EV kit provides two SAS/SATA connectors (J1 and J2), one for connection to a SAS/SATA host (e.g., a PC) and the other for connection to a SAS/SATA device (e.g., a hard drive). Power ...
View Attachment - Northeast Power Coordinating Council
View Attachment - Northeast Power Coordinating Council

... The de facto industry standard for time synchronization of electric utility equipment has been IRIG-B, in both the 1-kHz amplitude modulated and the DC shift formats. Amplitude modulated IRIG-B is more secure against most types of interference and is more suitable for larger interconnection networks ...
Power Generation Controls
Power Generation Controls

... load, or once a user-defined time has passed, transfer the system load in order of load priority to the engine-generators that are online. Each load shall be controlled by its own ‘load add’ and ‘load shed’ control relays. ...
< 1 ... 138 139 140 141 142 143 144 145 146 ... 838 >

Metadyne



A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report