5968-8153EN
... of existing N2862B/63B/90A for better performance. The N2853A is a 10:1 passive probe with 2 m cable length for extended cable connection. The N2873A/N2894A are 500-MHz/ 700 MHz 10:1 miniature passive probes that can be used with all InfiniiVision Series. Compact 2.5-mm probe head diameter, low inpu ...
... of existing N2862B/63B/90A for better performance. The N2853A is a 10:1 passive probe with 2 m cable length for extended cable connection. The N2873A/N2894A are 500-MHz/ 700 MHz 10:1 miniature passive probes that can be used with all InfiniiVision Series. Compact 2.5-mm probe head diameter, low inpu ...
P7380 8 GHz 5X/25X Differential Probe Technical
... Differential Measurements A differential probe is optimized to make measurements of high speed differential signals. Differential signals are formed from two complementary signal with a common reference voltage. See Figure 4. Devices designed for differential measurements avoid problems presented by ...
... Differential Measurements A differential probe is optimized to make measurements of high speed differential signals. Differential signals are formed from two complementary signal with a common reference voltage. See Figure 4. Devices designed for differential measurements avoid problems presented by ...
AK4376A - Asahi Kasei Microdevices
... Low-Power Advanced 32-bit DAC with HP 1. General Description The AK4376A is stereo advanced 32-bit high sound quality audio DAC with a built-in ground-referenced headphone amplifier. An internal circuit newly developed 32-bit digital filters for better sound quality, achieving low distortion charact ...
... Low-Power Advanced 32-bit DAC with HP 1. General Description The AK4376A is stereo advanced 32-bit high sound quality audio DAC with a built-in ground-referenced headphone amplifier. An internal circuit newly developed 32-bit digital filters for better sound quality, achieving low distortion charact ...
PulserPlus.Net Instruction Manual
... Table of Contents Section 1 – Quick Start Guide...................................................................................................................4 Section 2 – Equipment Overview.......................................................................................................... ...
... Table of Contents Section 1 – Quick Start Guide...................................................................................................................4 Section 2 – Equipment Overview.......................................................................................................... ...
Measuring and Increasing Z-Width with Active
... passivity is that the energy extracted from a system cannot exceed the initial energy in the system. This is typically determined by integrating the power produced over time, where power is defined as the product of force and velocity for translational mechanical systems. A passive haptic display ca ...
... passivity is that the energy extracted from a system cannot exceed the initial energy in the system. This is typically determined by integrating the power produced over time, where power is defined as the product of force and velocity for translational mechanical systems. A passive haptic display ca ...
Measuring and Increasing Z-Width with Active Electrical Damping
... passivity is that the energy extracted from a system cannot exceed the initial energy in the system. This is typically determined by integrating the power produced over time, where power is defined as the product of force and velocity for translational mechanical systems. A passive haptic display ca ...
... passivity is that the energy extracted from a system cannot exceed the initial energy in the system. This is typically determined by integrating the power produced over time, where power is defined as the product of force and velocity for translational mechanical systems. A passive haptic display ca ...
IPB-5000A - AMADA MIYACHI AMERICA
... When transporting or moving the Power Supply, do not lay it down. Also, handle the Power Supply with care so as not to make an impact such as drop on it. Install the Power Supply on a firm and level surface. If it is used inclined or on its side, it may have a malfunction. Also, provide 10 cm cl ...
... When transporting or moving the Power Supply, do not lay it down. Also, handle the Power Supply with care so as not to make an impact such as drop on it. Install the Power Supply on a firm and level surface. If it is used inclined or on its side, it may have a malfunction. Also, provide 10 cm cl ...
TRU - JYU Trac Help
... it. As far as I understood, it will be not used in final setup. They want to use the black-plane to operate with the board. Second test was the high-speed link. (1 input (40MHz clock from STU, later the LHC clock), 3 output links) We were sending 450 words in packet, instead of 96. We solved also so ...
... it. As far as I understood, it will be not used in final setup. They want to use the black-plane to operate with the board. Second test was the high-speed link. (1 input (40MHz clock from STU, later the LHC clock), 3 output links) We were sending 450 words in packet, instead of 96. We solved also so ...
care and feeding of power grid tubes - F1FRV
... 200. The low µ tubes are generally used in audio service or any application which requires a large change in anode current without driving the tube into the positive grid region. The difference between a tube with a µ of 5 and one with a µ of 160 can be seen by comparing Figure 1 to Figure 2. Observ ...
... 200. The low µ tubes are generally used in audio service or any application which requires a large change in anode current without driving the tube into the positive grid region. The difference between a tube with a µ of 5 and one with a µ of 160 can be seen by comparing Figure 1 to Figure 2. Observ ...
Service Manual - Fluke Calibration
... of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered, ...
... of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke’s opinion, has been misused, altered, ...
MODEL SR850 DSP Lock-In Amplifier
... change in the fuse holder voltage card position and fuse value. Disconnect the power cord, open the fuse holder cover door and rotate the fuse-pull lever to remove the fuse. Remove the small printed circuit board and select the operating voltage by orienting the printed circuit board so that the des ...
... change in the fuse holder voltage card position and fuse value. Disconnect the power cord, open the fuse holder cover door and rotate the fuse-pull lever to remove the fuse. Remove the small printed circuit board and select the operating voltage by orienting the printed circuit board so that the des ...
Lecture Notes on Beam Instrumentation and Diagnostics
... a synchrotron is needed to reach significant relativistic conditions. Another difference is the emission of synchrotron radiation by electrons, while this process occurs for protons only at the highest reachable energies, like in LHC. As seen from Table 1.1 the same beam quantity can be determined w ...
... a synchrotron is needed to reach significant relativistic conditions. Another difference is the emission of synchrotron radiation by electrons, while this process occurs for protons only at the highest reachable energies, like in LHC. As seen from Table 1.1 the same beam quantity can be determined w ...
14-Bit, 500 MSPS LVDS, Dual Analog-to
... threshold, the fast detect indicator goes high. Because this threshold indicator has low latency, the user can quickly reduce the system gain to avoid an overrange condition at the ADC input. In addition to the fast detect outputs, the AD9684 also offers signal monitoring capability. The signal moni ...
... threshold, the fast detect indicator goes high. Because this threshold indicator has low latency, the user can quickly reduce the system gain to avoid an overrange condition at the ADC input. In addition to the fast detect outputs, the AD9684 also offers signal monitoring capability. The signal moni ...
MAX5318 18-Bit, High-Accuracy Voltage Output DAC with Digital
... Q0.5ppm/NC of FSR (typ). The force-sense output (OUT) maintains accuracy while driving loads with long lead lengths. Additionally, a separate AVSS supply, allows the output amplifier to go to 0V (GND) while maintaining full linearity performance. The MAX5318 includes user-programmable digital gain a ...
... Q0.5ppm/NC of FSR (typ). The force-sense output (OUT) maintains accuracy while driving loads with long lead lengths. Additionally, a separate AVSS supply, allows the output amplifier to go to 0V (GND) while maintaining full linearity performance. The MAX5318 includes user-programmable digital gain a ...
Service Manual
... The CPU board is powered by two independent external power supplies, a +5V supply and a 12V supply. Two 5A fuses are respectively installed on the two power entries. The +5V supply is converted a +3.3V supply to power the digital components and the +3.3V supply is also further converted into a +1.5V ...
... The CPU board is powered by two independent external power supplies, a +5V supply and a 12V supply. Two 5A fuses are respectively installed on the two power entries. The +5V supply is converted a +3.3V supply to power the digital components and the +3.3V supply is also further converted into a +1.5V ...
Navy Electricity and Electronics Training Series
... The Navy Electricity and Electronics Training Series (NEETS) was developed for use by personnel in many electrical- and electronic-related Navy ratings. Written by, and with the advice of, senior technicians in these ratings, this series provides beginners with fundamental electrical and electronic ...
... The Navy Electricity and Electronics Training Series (NEETS) was developed for use by personnel in many electrical- and electronic-related Navy ratings. Written by, and with the advice of, senior technicians in these ratings, this series provides beginners with fundamental electrical and electronic ...
Analog input module AI 4xRTD/TC 2-/3-/4-wire HF
... Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo ...
... Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo ...
MAX4744/MAX4744H/MAX4745/MAX4745H/MAX4746H Low-Voltage, Dual SPDT, Audio Clickless Switches with Negative Rail Capability General Description
... CL INCLUDES FIXTURE AND STRAY CAPACITANCE ...
... CL INCLUDES FIXTURE AND STRAY CAPACITANCE ...
AD7466 数据手册DataSheet 下载
... The AD7466/AD7467/AD7468 are 12-/10-/8-bit, high speed, low power, successive approximation analog-to-digital converters (ADCs), respectively. The parts operate from a single 1.6 V to 3.6 V power supply and feature throughput rates up to 200 kSPS with low power dissipation. The parts contain a low n ...
... The AD7466/AD7467/AD7468 are 12-/10-/8-bit, high speed, low power, successive approximation analog-to-digital converters (ADCs), respectively. The parts operate from a single 1.6 V to 3.6 V power supply and feature throughput rates up to 200 kSPS with low power dissipation. The parts contain a low n ...
Oscilloscope types
This is a subdivision of the Oscilloscope article, discussing the various types and models of oscilloscopes in greater detail.