Optidrive E2 Single Phase Output User Guide
... Please read the IMPORTANT SAFETY INFORMATION below, and all Warning and Caution information elsewhere. Danger : Indicates a risk of electric shock, which, if not Danger : Indicates a potentially hazardous situation avoided, could result in damage to the equipment and other than electrical, which if ...
... Please read the IMPORTANT SAFETY INFORMATION below, and all Warning and Caution information elsewhere. Danger : Indicates a risk of electric shock, which, if not Danger : Indicates a potentially hazardous situation avoided, could result in damage to the equipment and other than electrical, which if ...
TPS40090 数据资料 dataSheet 下载
... The TPS4009x is a two-, three-, or four-phase programmable synchronous buck controller that is optimized for low-voltage, high-current applications powered by a 5-V to 15-V distributed supply. A multi-phase converter offers several advantages over a single power stage including lower current ripple ...
... The TPS4009x is a two-, three-, or four-phase programmable synchronous buck controller that is optimized for low-voltage, high-current applications powered by a 5-V to 15-V distributed supply. A multi-phase converter offers several advantages over a single power stage including lower current ripple ...
a Precision Instrumentation Amplifier AD624
... the high level of performance that this circuit architecture is capable of. A preamp section (Q1–Q4) develops the programmed gain by the use of feedback concepts. Feedback from the outputs of A1 and A2 forces the collector currents of Q1–Q4 to be constant thereby impressing the input voltage across ...
... the high level of performance that this circuit architecture is capable of. A preamp section (Q1–Q4) develops the programmed gain by the use of feedback concepts. Feedback from the outputs of A1 and A2 forces the collector currents of Q1–Q4 to be constant thereby impressing the input voltage across ...
AD9241 数据手册DataSheet 下载
... interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) is equally suited for both multiplexed systems that switch ful ...
... interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) is equally suited for both multiplexed systems that switch ful ...
Logarithmic Representation of signal Levels “Decibel Notation dB”
... AV A1 Atten A2 A3 600 AdB 20 log 600 55.6 ...
... AV A1 Atten A2 A3 600 AdB 20 log 600 55.6 ...
- Richtek
... RT2875 will start to skip pulses to maintain regulated output voltage. But output ripple will increase in pulse skip operation due to pulse grouping, so this operation mode should generally be avoided. The design tool will give a warning message when selecting parameters which result in hitting mini ...
... RT2875 will start to skip pulses to maintain regulated output voltage. But output ripple will increase in pulse skip operation due to pulse grouping, so this operation mode should generally be avoided. The design tool will give a warning message when selecting parameters which result in hitting mini ...
Higher Engineering Science Electronics and Control Book 2 of 3
... From your studies at National 5 you will already be aware that a transistor acts as an electronic switch that switches on when the voltage across the base-emitter junction is 0.7V. However, the transistor also performs an invaluable function - it acts as a current amplifier. Input transducers rarely ...
... From your studies at National 5 you will already be aware that a transistor acts as an electronic switch that switches on when the voltage across the base-emitter junction is 0.7V. However, the transistor also performs an invaluable function - it acts as a current amplifier. Input transducers rarely ...
ZETA Converter based charge controller for efficient use of solar
... An important thing to make the DC generated power more efficient is to use DC-DC converters to store and utilize the energy. The conversion from DC-AC causes a huge loss of power. Many types of DC-DC converters can be used for the purpose and every converter have its own advantages over others. Aim ...
... An important thing to make the DC generated power more efficient is to use DC-DC converters to store and utilize the energy. The conversion from DC-AC causes a huge loss of power. Many types of DC-DC converters can be used for the purpose and every converter have its own advantages over others. Aim ...
P6022 Current Probe Instruction Manual
... circuit you are measuring. This additional impedance affects signals; this is particularly important if you are measuring fast rise times. Figure 2 illustrates the equivalent circuit with additional impedance introduced by the P6022. ...
... circuit you are measuring. This additional impedance affects signals; this is particularly important if you are measuring fast rise times. Figure 2 illustrates the equivalent circuit with additional impedance introduced by the P6022. ...
ADF4106
... Input to the RF Prescaler. This small signal input is ac coupled to the external VCO. Analog Power Supply. This may range from 2.7 V to 3.3 V. Decoupling capacitors to the analog ground plane should be placed as close as possible to this pin. AVDD must be the same value as DVDD. Reference Input. Thi ...
... Input to the RF Prescaler. This small signal input is ac coupled to the external VCO. Analog Power Supply. This may range from 2.7 V to 3.3 V. Decoupling capacitors to the analog ground plane should be placed as close as possible to this pin. AVDD must be the same value as DVDD. Reference Input. Thi ...
Testing of Conducted Energy Weapons CPRC
... X00-009704 had a slightly higher output voltage than specified. In the letter from Taser International date 21 May 2008 Max Nerheim Vice President, Research and development provides background information on the tolerances which explain this. “Voltagre (sic) and current measurements into 250 ohm loa ...
... X00-009704 had a slightly higher output voltage than specified. In the letter from Taser International date 21 May 2008 Max Nerheim Vice President, Research and development provides background information on the tolerances which explain this. “Voltagre (sic) and current measurements into 250 ohm loa ...
ound Devices 664 Mixer/RecorderTutorial
... certification. During the “Open House” practice sessions not only will you be able to get handson practice in setting up and “striking” the SOUND DEVICES 664 MIXER/RECORDER remote equipment, but also a chance to ask the ACM Media Center staff any questions you might have regarding the equipment and/ ...
... certification. During the “Open House” practice sessions not only will you be able to get handson practice in setting up and “striking” the SOUND DEVICES 664 MIXER/RECORDER remote equipment, but also a chance to ask the ACM Media Center staff any questions you might have regarding the equipment and/ ...
Dual Input Reset Generator
... inputs must go low and stay low for a predetermined period (tLOW_DELAY) to generate a single reset pulse on the output. MR1 and MR2 operate independently and may be brought low at any time and in any order. The last input to reach 0 V starts the delay timer. MR1 is a standard CMOS input and MR2 is a ...
... inputs must go low and stay low for a predetermined period (tLOW_DELAY) to generate a single reset pulse on the output. MR1 and MR2 operate independently and may be brought low at any time and in any order. The last input to reach 0 V starts the delay timer. MR1 is a standard CMOS input and MR2 is a ...
AD9241 Complete 14-Bit, 1.25 MSPS Monolithic A/D Converter
... interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) is equally suited for both multiplexed systems that switch ful ...
... interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) is equally suited for both multiplexed systems that switch ful ...
MAX1779 Low-Power Triple-Output TFT LCD DC-DC Converter General Description
... +5.5V input supply voltage into three independent output voltages. The primary high-power DC-DC converter generates a boosted output voltage (VMAIN) up to 13V that is regulated within ±1%. The low-power BiCMOS control circuitry and the low on-resistance (1Ω) of the integrated power MOSFET allows eff ...
... +5.5V input supply voltage into three independent output voltages. The primary high-power DC-DC converter generates a boosted output voltage (VMAIN) up to 13V that is regulated within ±1%. The low-power BiCMOS control circuitry and the low on-resistance (1Ω) of the integrated power MOSFET allows eff ...
Speed Variator Sensitive Relay Card Instructions
... The function is applied in either open- or closedloop circuits. In many applications the card is employed to switch a signal or pick up another relay whenever it is actuated. In other cases it is the forward gain element in a closed-loop system. In this general area of application, whenever the rela ...
... The function is applied in either open- or closedloop circuits. In many applications the card is employed to switch a signal or pick up another relay whenever it is actuated. In other cases it is the forward gain element in a closed-loop system. In this general area of application, whenever the rela ...
Oscilloscope history