• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The Response of Measuring Systems
The Response of Measuring Systems

... same way. If a 100-Hz sine wave with an input amplitude of 5 units is fed into a system and a peak-topeak output of 2 in. results on an oscilloscope screen, we can expect that a 500-Hz sine-wave input of the same amplitude would also result in a 2-in. peak-to-peak output. Changing the frequency of ...
TV Engineering QUESTION BANK - E
TV Engineering QUESTION BANK - E

Touch screens
Touch screens

... • Uniform PD on back plate, front plate used as probe to get voltage V2(X) • Uniform PD on front plate, back plate used as probe to get voltage V2(Y) • Use A to D converter for Cartesian coordinates ...
expt11
expt11

... power source. We will use a small power supply that provides these voltages plus a zero to ±5 V variable DC output. The op-amp will supply a maximum output current of about 25 mA and has typical offset currents of about 20 nA. This implies that resistors in the range 1 k to 100 k should be used. U ...
XR2206 Functional Generator kits The module described here is
XR2206 Functional Generator kits The module described here is

...  The sine wave and triangle wave can be selected by SWITCH1 SWITCH1: Open for Triangle Closed for Sine wave  Amplitude and frequency is controlled by two potentiometers. Potentiometers R5 and R6 are used for Amplitude adjustment and Frequency adjustment.  R5: Amplitude Adjustment  R6: Frequency ...
Download the Quiz
Download the Quiz

Principles of Electronic Communication Systems
Principles of Electronic Communication Systems

1 - JustAnswer
1 - JustAnswer

... waveforms shown will appear between terminals A and B after the switch is opened? A). waveform 1 ...
Slide 1
Slide 1

P5.6.2.1 - LD Didactic
P5.6.2.1 - LD Didactic

LDC500 Series: RF Modulation of Injection Current
LDC500 Series: RF Modulation of Injection Current

... In cathode injection, the laser anode is grounded to RF  source  chassis  and  the  RF  signal  is  injected  to  the  cathode  through  R  and  C.  Resistor  R  together  with  the  laser  diode  internal AC resistance should match the RF cable impedance.  Capacitor  C  is  used  to  block  the  po ...
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher

... This mode may be used with already gaussian shaped signals, or preamplifier signals where the decay time is too short to adjust PZC properly. This mode is not preferred as it does not provide time resolution to do pile-up suppression and also the spectral resolution to be obtained may not be optimum ...
Chapter 5 - William Stallings, Data and Computer
Chapter 5 - William Stallings, Data and Computer

... no transition i.e. no return to zero voltage such as absence of voltage for zero, constant positive voltage for one more often, negative voltage for one value and positive for the other ...
Power function generator with integral feedback voltage protection
Power function generator with integral feedback voltage protection

... any external voltages of up to 120 V will not destroy its output stage. Furthermore, all front-panel inputs and outputs are no-load and short-circuit proof. The frequency settings are made using a decade switch, the frequency dial and the frequency offset potentiometer. The latter allows frequency s ...
412 Laboratory #1: Input Resistance, Output Resistance, and Gain
412 Laboratory #1: Input Resistance, Output Resistance, and Gain

... performance of cascaded amplifiers. To show how an equivalent linear amplifier model using these three parameters can be used to predict circuit performance. ...
Chapter Two Voltage and Current Measurement
Chapter Two Voltage and Current Measurement

... 1.1 Simple Instrument Model pp.4 ...
555 Timer As Mono Stable Multi Vibrator
555 Timer As Mono Stable Multi Vibrator

MDP-1 Brochure 8/01
MDP-1 Brochure 8/01

... source directly to tape or hard disk. Unlike vintage or hybrid designs, the MDP-1 uses a pure tube, class A high voltage circuit topology with a transformerless output stage to deliver an open, intimate sound with a level of detail that meets the requirements of the most demanding recording applicat ...
A Trigger System with High Voltage Isolation for
A Trigger System with High Voltage Isolation for

... The semiconductor switches are the main elements of all kind of power converters or pulse power supply design. So, the trigger pulses to control these switches play most important role in these designs. There are a number of research papers related to these designs based on different topologies. But ...
Operational Amplifiers in Chemical Instrumentation
Operational Amplifiers in Chemical Instrumentation

... modern analog signal-conditioning circuits owe their success to the class of integrated circuits known as operational amplifiers , which can be referred to as op amps . ► If you open any instrument or piece of electronic equipment, it would be likely to find one or more op amps . ...
16spMid1b
16spMid1b

... Both devices are in saturation, and the quadratic model is appropriate. The low frequency gain is -1000. Cgs1=1pF, Cgd1=0.1pF. ...
Loop and Nodal Analysis and Op Amps
Loop and Nodal Analysis and Op Amps

... made, value of Resistor(s) (measure with DMM), oscilloscope time and voltage measurements, and frequency of square wave(s). Procedure Description  Describe test circuit (use a figure with node labels that you can refer to in your discussion !!!!!) and discuss grounding for scope probe and function ...
UNIT 5 - WordPress.com
UNIT 5 - WordPress.com

... voltage Vin at the inverting input is concerned during its negative half-cycle D1 conducts, charging C1 to the negative peak value of the VP. However, during the positive half-cycle of Vin diode D1 is reverse biased and hence the voltage VP across the capacitor acquired during the negative half-cycl ...
Capacitors including RC Circuits
Capacitors including RC Circuits

... (the buttons may have wavy lines for AC and straight lines for DC). The multimeter may have three holes with two leads (wires) coming out. If so make sure the upper lead is plugged into the hole that indicates V (not A). Put one needle into each side of the capacitor as shown below. ...
Name(s): Physics 202 Part I. (Capacitors in parallel) Geometry (size
Name(s): Physics 202 Part I. (Capacitors in parallel) Geometry (size

... (the buttons may have wavy lines for AC and straight lines for DC). The multimeter may have three holes with two leads (wires) coming out. If so make sure the upper lead is plugged into the hole that indicates V (not A). Put one needle into each side of the capacitor as shown below. ...
< 1 ... 348 349 350 351 352 353 354 355 356 ... 395 >

Oscilloscope history



This article discusses the history and development of oscilloscope technology.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report