File - Vijay Solanki
... waveform is known as its "periodic time" or simply the Period of the waveform. In other words, the time it takes for the waveform to repeat itself. Then this period can vary with each waveform from fractions of a second to thousands of seconds as it depends upon the frequency of the waveform. For ...
... waveform is known as its "periodic time" or simply the Period of the waveform. In other words, the time it takes for the waveform to repeat itself. Then this period can vary with each waveform from fractions of a second to thousands of seconds as it depends upon the frequency of the waveform. For ...
FEATURES FUNCTIONAL BLOCK DIAGRAM
... The ADG201A-EP is a monolithic CMOS device comprising four independently selectable switches. They are designed on an enhanced LC2MOS process, which gives an increased signal handling capability of ±15 V. These switches also feature high switching speeds and low RON. ...
... The ADG201A-EP is a monolithic CMOS device comprising four independently selectable switches. They are designed on an enhanced LC2MOS process, which gives an increased signal handling capability of ±15 V. These switches also feature high switching speeds and low RON. ...
DM-300 Series Brochure
... Four Multimeters, Four Reasons To Buy Greenlee DM-300 Series Digital Multimeters... Improving testing one meter at a time Greenlee’s introduction of the DM-300 Series digital multimeters gives the electrician four more reasons to own a Greenlee test instrument and is an extension of the already bro ...
... Four Multimeters, Four Reasons To Buy Greenlee DM-300 Series Digital Multimeters... Improving testing one meter at a time Greenlee’s introduction of the DM-300 Series digital multimeters gives the electrician four more reasons to own a Greenlee test instrument and is an extension of the already bro ...
AD828
... equals the parallel combination of RIN and RF and thus provides a matched impedance at each input terminal. The offset voltage error will then be reduced by more than an order of magnitude. ...
... equals the parallel combination of RIN and RF and thus provides a matched impedance at each input terminal. The offset voltage error will then be reduced by more than an order of magnitude. ...
Tutorial 1
... 4. An average value of a set of voltage measurement is 30.15V. Calculate the precision of the measurement if one of the measurement readings is 29.9V. 5. A voltmeter has an accuracy of 98% in full-scale measurement readings. a. If the voltmeter gives measurement reading of 175V at range of 300V, cal ...
... 4. An average value of a set of voltage measurement is 30.15V. Calculate the precision of the measurement if one of the measurement readings is 29.9V. 5. A voltmeter has an accuracy of 98% in full-scale measurement readings. a. If the voltmeter gives measurement reading of 175V at range of 300V, cal ...
report
... A/D converter system usually consists of a quantizer along with other signal conditioning circuitry such as amplifiers, filters, sample-and-hold circuits etc. Despite this difference, the terms quantizer and A/D converter are often used synonymously. A quantizer can be uniquely described by its tran ...
... A/D converter system usually consists of a quantizer along with other signal conditioning circuitry such as amplifiers, filters, sample-and-hold circuits etc. Despite this difference, the terms quantizer and A/D converter are often used synonymously. A quantizer can be uniquely described by its tran ...
Do`s and Don`ts for PCB Layer Stack-up
... Do not overlap power supply layer and digital high speed signal layer. It is recommended to prepare layer partition map after components placement. ...
... Do not overlap power supply layer and digital high speed signal layer. It is recommended to prepare layer partition map after components placement. ...
AVR449: Sinusoidal driving of 3-phase
... in substantial power dissipation in the filter itself, an undesirable energy loss. 3.1.2 Dead-time Switching devices, such as MOSFET transistors are not able to switch on and off instantly. Consider again the half-bridge from Figure 3-1. If the switches PWMH and PWML are fed with inverted signals, o ...
... in substantial power dissipation in the filter itself, an undesirable energy loss. 3.1.2 Dead-time Switching devices, such as MOSFET transistors are not able to switch on and off instantly. Consider again the half-bridge from Figure 3-1. If the switches PWMH and PWML are fed with inverted signals, o ...
Practical 1 RC Circuits Objectives
... the two plates. Hence, there is a voltage difference between the plates. If, sometime later, we connect the plates again, this time with a light bulb in place of the battery, the plates will discharge: the electrons on the negatively charged plate will move around the circuit to the positive plate u ...
... the two plates. Hence, there is a voltage difference between the plates. If, sometime later, we connect the plates again, this time with a light bulb in place of the battery, the plates will discharge: the electrons on the negatively charged plate will move around the circuit to the positive plate u ...
Datasheet - STMicroelectronics
... The RHF1201 is a 12-bit, 50 Msps sampling frequency analog-to-digital converter that uses pure (ELDRS-free) CMOS 0.25 µm technology combining high performance, radiation robustness, and very low power consumption. The device is based on a pipeline structure and digital error correction to provide ex ...
... The RHF1201 is a 12-bit, 50 Msps sampling frequency analog-to-digital converter that uses pure (ELDRS-free) CMOS 0.25 µm technology combining high performance, radiation robustness, and very low power consumption. The device is based on a pipeline structure and digital error correction to provide ex ...
LM124/LM224/LM324/LM2902 Low Power Quad Operational
... Note 3: This input current will only exist when the voltage at any of the input leads is driven negative. It is due to the collector-base junction of the input PNP transistors becoming forward biased and thereby acting as input diode a clamps. In addition to this diode action, there is also lateral ...
... Note 3: This input current will only exist when the voltage at any of the input leads is driven negative. It is due to the collector-base junction of the input PNP transistors becoming forward biased and thereby acting as input diode a clamps. In addition to this diode action, there is also lateral ...
FMS6143A Three-Channel 6 -Order Standard-Definition VoltagePlus™ Video Filter Driver
... the internal DC offset, keeps the output within its acceptable range. ...
... the internal DC offset, keeps the output within its acceptable range. ...
LM124 LM224 LM324 LM2902 Low Power Quad Operational
... Note 3: This input current will only exist when the voltage at any of the input leads is driven negative. It is due to the collector-base junction of the input PNP transistors becoming forward biased and thereby acting as input diode a clamps. In addition to this diode action, there is also lateral ...
... Note 3: This input current will only exist when the voltage at any of the input leads is driven negative. It is due to the collector-base junction of the input PNP transistors becoming forward biased and thereby acting as input diode a clamps. In addition to this diode action, there is also lateral ...
TLV5535-Q1 数据资料 dataSheet 下载
... description/ordering information The TLV5535 is an 8-bit, 35 MSPS, high-speed A/D converter. It converts the analog input signal into 8-bit binary-coded digital words up to a sampling rate of 35 MHz. All digital inputs and outputs are 3.3 V TTL /CMOS-compatible. The device consumes very little power ...
... description/ordering information The TLV5535 is an 8-bit, 35 MSPS, high-speed A/D converter. It converts the analog input signal into 8-bit binary-coded digital words up to a sampling rate of 35 MHz. All digital inputs and outputs are 3.3 V TTL /CMOS-compatible. The device consumes very little power ...
Pendulum MDP-1 Operating Manual
... fuse is accessible from the rear panel and is rated at 1A/250V (3AG) SLOBLO. To check or replace the fuse, make sure the unit is unplugged. Operation at 240V/50Hz is available as an option. Please contact us for more information. Servicing Other than changing the tubes, the user should not attempt t ...
... fuse is accessible from the rear panel and is rated at 1A/250V (3AG) SLOBLO. To check or replace the fuse, make sure the unit is unplugged. Operation at 240V/50Hz is available as an option. Please contact us for more information. Servicing Other than changing the tubes, the user should not attempt t ...
Oscilloscope history
This article discusses the history and development of oscilloscope technology.