HYDRA-X10 User Manual - Active-Semi
... goes above 16V, the system exits UVLO protection and all subsystems, including voltage regulators, analog front end and microcontroller, are enabled. When an operational voltage is applied, LED D2 will light up. This is the LED which notifies VSYS (5V) rail is up and running. 3.3V and 1.8V regulator ...
... goes above 16V, the system exits UVLO protection and all subsystems, including voltage regulators, analog front end and microcontroller, are enabled. When an operational voltage is applied, LED D2 will light up. This is the LED which notifies VSYS (5V) rail is up and running. 3.3V and 1.8V regulator ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... Latch type sense amplifier are used to read the contents of the different type of memory , A/D converters, data receivers and on-chip transistors as they yield fast decision due to positive feedback [3].Figure 4 shows the circuit diagram of the latch type voltage sense amplifier to generate positive ...
... Latch type sense amplifier are used to read the contents of the different type of memory , A/D converters, data receivers and on-chip transistors as they yield fast decision due to positive feedback [3].Figure 4 shows the circuit diagram of the latch type voltage sense amplifier to generate positive ...
Johnson/Evinrude 60° 6 Cylinder Optical Ignition (OIS
... other Johnson/Evinrude Quick-Start ignitions use stator charge coils and a power coil to provide high voltage and power for the Quick-Start and rev limiter circuits. They require a sensor for triggering and use separate magnets for the high voltage and triggering the sensor. The OIS 2000 Optical sys ...
... other Johnson/Evinrude Quick-Start ignitions use stator charge coils and a power coil to provide high voltage and power for the Quick-Start and rev limiter circuits. They require a sensor for triggering and use separate magnets for the high voltage and triggering the sensor. The OIS 2000 Optical sys ...
Mojotone Tweed Princeton Style Amp Kit Instruction
... b) Test tube socket voltage with a multimeter to ensure correct operation. c) Plug in speaker d) Turn amp on without tubes installed first, checking transformers and components for shorting, excessive heat, arcing, smoking, etc. e) Turn Amp off before putting tubes in proper location, and allow tube ...
... b) Test tube socket voltage with a multimeter to ensure correct operation. c) Plug in speaker d) Turn amp on without tubes installed first, checking transformers and components for shorting, excessive heat, arcing, smoking, etc. e) Turn Amp off before putting tubes in proper location, and allow tube ...
Document
... Reverse-active (or inverse-active or inverted): By reversing the biasing conditions of the forward-active region, a bipolar transistor goes into reverse-active mode. In this mode, the emitter and collector regions switch roles. Since most BJTs are designed to maximise current gain in forward-active ...
... Reverse-active (or inverse-active or inverted): By reversing the biasing conditions of the forward-active region, a bipolar transistor goes into reverse-active mode. In this mode, the emitter and collector regions switch roles. Since most BJTs are designed to maximise current gain in forward-active ...
62-814.450 Electric and Magnetic Field Standards.
... "Distribution Line" means a system of conductors used to transport electrical energy at voltages of less than 69 kV including service drops from transformers to residences or businesses. ...
... "Distribution Line" means a system of conductors used to transport electrical energy at voltages of less than 69 kV including service drops from transformers to residences or businesses. ...
SOT23 Dual-Input USB/AC Adapter 1-Cell Li+ Battery Chargers General Description Features
... portable users to forgo carrying a wall cube. These devices operate with no external FETs or diodes, and accept operating input voltages up to 7V. An internal thermal control loop simplifies PC board layout and allows optimum charging rate without the thermal limits imposed by worst-case battery and ...
... portable users to forgo carrying a wall cube. These devices operate with no external FETs or diodes, and accept operating input voltages up to 7V. An internal thermal control loop simplifies PC board layout and allows optimum charging rate without the thermal limits imposed by worst-case battery and ...
Electrical Installation Guide 2016 | Schneider Electric
... and heat. This energy is measured by kWh meters, and is referred to as “active” or “wattful” energy. In order to perform this conversion, magnetic fields have to be established in the machines, and these fields are associated with another form of energy to be supplied from the power system, known as ...
... and heat. This energy is measured by kWh meters, and is referred to as “active” or “wattful” energy. In order to perform this conversion, magnetic fields have to be established in the machines, and these fields are associated with another form of energy to be supplied from the power system, known as ...
User`s Guide True RMS Industrial Multimeter Extech EX530
... CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green VAC/Hz/% position. 2. Insert the black test lead banana plug into the negative COM jack. Insert red test lead b ...
... CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green VAC/Hz/% position. 2. Insert the black test lead banana plug into the negative COM jack. Insert red test lead b ...
Alberta Reliability Standard Transmission Relay Loadability PRC-023-AB-2
... This reliability standard applies to: (a) a legal owner of a transmission facility with load-responsive phase protection systems, as described in Appendix 1 applied to any one (1) or more of the following facilities: (i) transmission lines operated at two hundred (200) kV and above; (ii) transmissio ...
... This reliability standard applies to: (a) a legal owner of a transmission facility with load-responsive phase protection systems, as described in Appendix 1 applied to any one (1) or more of the following facilities: (i) transmission lines operated at two hundred (200) kV and above; (ii) transmissio ...
BQ20Z60-R1 数据资料 dataSheet 下载
... The bq20z60-R1 charge control features include: • Supports JEITA temperature ranges. Reports charging voltage and charging current according to the active temperature range. • Handles more complex charging profiles. Allows for splitting the standard temperature range into 2 sub-ranges and allows for ...
... The bq20z60-R1 charge control features include: • Supports JEITA temperature ranges. Reports charging voltage and charging current according to the active temperature range. • Handles more complex charging profiles. Allows for splitting the standard temperature range into 2 sub-ranges and allows for ...
Analysis and Demonstration of MEM
... power consumed by inactive CMOS logic circuits. However, the finite Ion/Ioff ratio of MOSFET power gates limits their ability to reduce off-state leakage. In contrast, as described in [1], MEMS-based power gates that mechanically make or break electrical contact can completely eliminate off-state le ...
... power consumed by inactive CMOS logic circuits. However, the finite Ion/Ioff ratio of MOSFET power gates limits their ability to reduce off-state leakage. In contrast, as described in [1], MEMS-based power gates that mechanically make or break electrical contact can completely eliminate off-state le ...
BD733L5FP-C
... (e.g. short circuit, open circuit, etc.). Therefore, if any special mode is being considered with values expected to exceed the absolute maximum ratings, implementing physical safety measures, such as adding fuses, should be considered. 2) The electrical characteristics given in this specification m ...
... (e.g. short circuit, open circuit, etc.). Therefore, if any special mode is being considered with values expected to exceed the absolute maximum ratings, implementing physical safety measures, such as adding fuses, should be considered. 2) The electrical characteristics given in this specification m ...
3. Corrosive atmosphere features
... To make them easier to operate and maintain, all functional units of the same type and rating will be interchangeable, unless a foolproofing system is installed. To facilitate upgrading, it will be possible to add a functional distribution and motor control unit of up to 630 A in the same column, wi ...
... To make them easier to operate and maintain, all functional units of the same type and rating will be interchangeable, unless a foolproofing system is installed. To facilitate upgrading, it will be possible to add a functional distribution and motor control unit of up to 630 A in the same column, wi ...
Fundamentals of Power Electronics
... • Increasing switching frequency increases switching loss: Psw = fsw ∆vds Qsw • Much R&D effort has been devoted to increasing the switching frequency and reducing the loss in highdensity power supplies • Approaches to achieve these goals include use of resonant converters and soft switching techniq ...
... • Increasing switching frequency increases switching loss: Psw = fsw ∆vds Qsw • Much R&D effort has been devoted to increasing the switching frequency and reducing the loss in highdensity power supplies • Approaches to achieve these goals include use of resonant converters and soft switching techniq ...
ETU-LINK Product Specification - ETU
... The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, ETU-LINK SFP+ transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows r ...
... The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information. Additionally, ETU-LINK SFP+ transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows r ...
Differential Measurements
... Another common problem with A-B measurements is scope channel & probe accuracy. If the scope & probes have an accuracy specification of 1%, which is typical, the magnitude of a 100 volt sine wave could appear to the scope as 99 volts while a 99.9 volts signal could well appear to be 100.899 volts. S ...
... Another common problem with A-B measurements is scope channel & probe accuracy. If the scope & probes have an accuracy specification of 1%, which is typical, the magnitude of a 100 volt sine wave could appear to the scope as 99 volts while a 99.9 volts signal could well appear to be 100.899 volts. S ...
2N5191 - Silicon NPN Power Transistors
... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
LM3670 - Texas Instruments
... frequency modulation (PFM), and shutdown. PWM mode handles current loads of approximately 70 mA or higher. Lighter output current loads cause the device to automatically switch into PFM for reduced current consumption (IQ = 15 µA typical) and a longer battery life. Shutdown mode turns off the device ...
... frequency modulation (PFM), and shutdown. PWM mode handles current loads of approximately 70 mA or higher. Lighter output current loads cause the device to automatically switch into PFM for reduced current consumption (IQ = 15 µA typical) and a longer battery life. Shutdown mode turns off the device ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).