AP1506 150KHz, 3A PWM BUCK DC/DC CONVERTER Description
... location, and even board temperature. Other factors are: trace width, total printed circuit copper area, copper thickness, single or double-sided, multi-layer board and the amount of solder on the board. The effectiveness of the PC board to dissipate heat also depends on the size, quantity and spaci ...
... location, and even board temperature. Other factors are: trace width, total printed circuit copper area, copper thickness, single or double-sided, multi-layer board and the amount of solder on the board. The effectiveness of the PC board to dissipate heat also depends on the size, quantity and spaci ...
全面认识开关型电源中的 BUCK-BOOST 应用报告 ZHCA041–1999年3月–2002年11月修订
... function of rated load are given. 时 整个开关周期内都有电流连续通过电感器 非连续电感器电流模式是开关周期内的一部分时间 It is,very desirable for a converter to stay;in one mode only over its expected operating 电感电流为because 达到一个峰值后 conditions the power stage frequency response changes significantly between the ,再回到 0,它在整个周期内从 0开始, ...
... function of rated load are given. 时 整个开关周期内都有电流连续通过电感器 非连续电感器电流模式是开关周期内的一部分时间 It is,very desirable for a converter to stay;in one mode only over its expected operating 电感电流为because 达到一个峰值后 conditions the power stage frequency response changes significantly between the ,再回到 0,它在整个周期内从 0开始, ...
Static characteristics of a new doubly salient permanent magnet motor
... without the PM are very different in both the magnitude and pattern. In addition, the strengthening and weakening actions of the armature field to the PM field have significant effects on the inductance value, which should be taken into account in performance prediction and control of the DSPM motor ...
... without the PM are very different in both the magnitude and pattern. In addition, the strengthening and weakening actions of the armature field to the PM field have significant effects on the inductance value, which should be taken into account in performance prediction and control of the DSPM motor ...
IEEE white paper
... and current ratings have increased and IGBTbased high power applications already exist, both parallel and series connected. A drawback with the higher power is that the dc-link capacitors store more energy. This causes a higher risk of IGBT case rupturing when a circuit failure condition occurs [1], ...
... and current ratings have increased and IGBTbased high power applications already exist, both parallel and series connected. A drawback with the higher power is that the dc-link capacitors store more energy. This causes a higher risk of IGBT case rupturing when a circuit failure condition occurs [1], ...
RSMC Instructions - Model Railroad Control Systems
... Turnout position feedback is provided from the Position Feedback pin. This is an open collector output and is set low (zero) when the reverse switch contacts are active. Route LEDs are driven by one set of internal contacts in the Tortoise. Stall motor voltage is routed from the external contacts t ...
... Turnout position feedback is provided from the Position Feedback pin. This is an open collector output and is set low (zero) when the reverse switch contacts are active. Route LEDs are driven by one set of internal contacts in the Tortoise. Stall motor voltage is routed from the external contacts t ...
ADM207E 数据手册DataSheet 下载
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
Evaluates: MAX1778/MAX1880/MAX1881/MAX1882 MAX1778 Evaluation Kit General Description Features
... configured for a +8V output that provides up to 250mA of current from a +3.0V supply. The EV kit can be powered from a +2.7V to +5.5V supply. The positive charge-pump circuit is configured for a +20V output that provides more than 10mA of current. The negative charge-pump circuit is configured for a ...
... configured for a +8V output that provides up to 250mA of current from a +3.0V supply. The EV kit can be powered from a +2.7V to +5.5V supply. The positive charge-pump circuit is configured for a +20V output that provides more than 10mA of current. The negative charge-pump circuit is configured for a ...
Monolite Operating Manual Alcad.qxd
... Equalize Charging Equalize or high rate charging should be used only when necessary. Frequent equalizing can result in water consumption, which will lead to reduced capacity and shortened battery life. If necessary for fast recharge, equalizing may be carried out at voltages up to ...
... Equalize Charging Equalize or high rate charging should be used only when necessary. Frequent equalizing can result in water consumption, which will lead to reduced capacity and shortened battery life. If necessary for fast recharge, equalizing may be carried out at voltages up to ...
Data Sheet
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
... compatibility (EMC) (89/336/EEC). The level of emissions and immunity are both in compliance. EM immunity includes ESD protection in excess of ±15 kV on all I/O lines (IEC 1000-4-2), fast transient burst protection (IEC 100044), and radiated immunity (IEC 1000-4-3). EM emissions include radiated a ...
Tether and Umbilical Cables
... encountered at full ocean depth and endure the mechanical stresses imposed during the repeated flexure affiliated with dynamic systems. TE’s ROV product line of heavy lift umbilical cables, neutrally buoyant tether cables and heavy tether cables for all lifting applications in offshore and marine en ...
... encountered at full ocean depth and endure the mechanical stresses imposed during the repeated flexure affiliated with dynamic systems. TE’s ROV product line of heavy lift umbilical cables, neutrally buoyant tether cables and heavy tether cables for all lifting applications in offshore and marine en ...
Power Factor Correction - MKK415-D-25-02MKK440-D-28.1
... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
isscc 2010 / session 16 / high-performance data
... a gain stage, requires a high-gain wide-bandwidth opamp and is the most critical building block. The opamps draw static currents from their power supplies and consume most of the power in a pipelined ADC. Many techniques have been reported to achieve a low-power design by avoiding the high-gain opam ...
... a gain stage, requires a high-gain wide-bandwidth opamp and is the most critical building block. The opamps draw static currents from their power supplies and consume most of the power in a pipelined ADC. Many techniques have been reported to achieve a low-power design by avoiding the high-gain opam ...
Loop Calibration and Maintenance with a Fluke Loop Calibrator
... The main purpose of a loop isolator is to eliminate ground loops in control systems while sending the control signal current to another part of the system. Loop-powered isolators, unlike two-wire transmitters, draw their operating power from the “input” side of the isolator (see Figure 1), which req ...
... The main purpose of a loop isolator is to eliminate ground loops in control systems while sending the control signal current to another part of the system. Loop-powered isolators, unlike two-wire transmitters, draw their operating power from the “input” side of the isolator (see Figure 1), which req ...
Critical Power Systems
... One issue unique to health care facilities, however, is the impact of imaging equipment such as CT scans on facility power quality. These devices use almost no power when idle, but draw a tremendous load when called into service. This presents the facility power systems with significant step loads t ...
... One issue unique to health care facilities, however, is the impact of imaging equipment such as CT scans on facility power quality. These devices use almost no power when idle, but draw a tremendous load when called into service. This presents the facility power systems with significant step loads t ...
TH-HOP-16GeneratorHopkinsTestQuestions
... AC current is passed through the rotor windings AC current is passed through the stator windings DC current is passed through the rotor windings DC current is passed through the stator windings ...
... AC current is passed through the rotor windings AC current is passed through the stator windings DC current is passed through the rotor windings DC current is passed through the stator windings ...
BDTIC www.BDTIC.com/infineon TLV4946K, TLV4946-2K
... Precise magnetic switching thresholds and high temperature stability are achieved by active compensation circuits and chopper techniques on chip. Offset voltages generated by temperature-induced stress or overmolding are canceled so that high accuracy is achieved. The IC has an open collector output ...
... Precise magnetic switching thresholds and high temperature stability are achieved by active compensation circuits and chopper techniques on chip. Offset voltages generated by temperature-induced stress or overmolding are canceled so that high accuracy is achieved. The IC has an open collector output ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).