High Accuracy Eddy Current Type Displacement Sensor
... Threshold level setting function, zeroadjust function, scale setting function, hysteresis setting function, start/hold function, auto-reference function, power supply ON-delay function, etc. This is a multi-functional controller having mathematical functions, hold function, etc. • Supply voltage: 10 ...
... Threshold level setting function, zeroadjust function, scale setting function, hysteresis setting function, start/hold function, auto-reference function, power supply ON-delay function, etc. This is a multi-functional controller having mathematical functions, hold function, etc. • Supply voltage: 10 ...
MAX13041 ±80V Fault-Protected High-Speed CAN Transceiver with Low-Power Management and Wake-On CAN
... device links a CAN protocol controller to the physical bus wires of the controller area network (CAN) and allows communication at speeds up to 1Mbps. Built-in level shifting allows for direct connection to protocol controllers operating from lower voltages. The extended fault-protected voltage range ...
... device links a CAN protocol controller to the physical bus wires of the controller area network (CAN) and allows communication at speeds up to 1Mbps. Built-in level shifting allows for direct connection to protocol controllers operating from lower voltages. The extended fault-protected voltage range ...
Effect and Utilization of Common Source Inductance in Synchronous
... caused by turn on of control FET Q1 will cause false turn on of sync FET Q2 and cause high power loss. With Sync FET common source inductance, this problem can be solved as shown in Fig.7. When control FET Q1 is turned on, first load current will commute from sync FET branch to Q1 branch. During thi ...
... caused by turn on of control FET Q1 will cause false turn on of sync FET Q2 and cause high power loss. With Sync FET common source inductance, this problem can be solved as shown in Fig.7. When control FET Q1 is turned on, first load current will commute from sync FET branch to Q1 branch. During thi ...
Manual of RC Timer ESC 30A Brushless Motor
... Usually, low timing value can be used for most motors. We recommend the Low timing value for 2 poles motor and Medium timing value for motors with more than 6 poles to get a high efficiency. For higher speed, High timing value can be chosen. ...
... Usually, low timing value can be used for most motors. We recommend the Low timing value for 2 poles motor and Medium timing value for motors with more than 6 poles to get a high efficiency. For higher speed, High timing value can be chosen. ...
BDTIC
... which is equal to the leakage current of the Zener diode.This is also a reason the leakage current of the TVS diode must be kept as low as possible. The described structure can handle a positive ESD strike only, because the PIN1 diode (serial to the Zener diode) can only hande the ESD current in for ...
... which is equal to the leakage current of the Zener diode.This is also a reason the leakage current of the TVS diode must be kept as low as possible. The described structure can handle a positive ESD strike only, because the PIN1 diode (serial to the Zener diode) can only hande the ESD current in for ...
D5V0P4B5LP08 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
B140WS Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
XHR 1000 Watt Series Programmable DC Power Supply
... Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application a ...
... Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application a ...
Product Summary
... efficiencies attained throughout the entire power range, the SKY77189 delivers unsurpassed talk-time advantages. The SKY77189 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency. A directional coupler is ...
... efficiencies attained throughout the entire power range, the SKY77189 delivers unsurpassed talk-time advantages. The SKY77189 meets the stringent spectral linearity requirements of High Speed Downlink Packet Access (HSDPA) data transmission with high power added efficiency. A directional coupler is ...
AP2161/ AP2171 Description Pin Assignments
... Generic Hot-Plug Applications In many applications it may be necessary to remove modules or pc boards while the main unit is still operating. These are considered hot-plug applications. Such implementations require the control of current surges seen by the main power supply and the card being insert ...
... Generic Hot-Plug Applications In many applications it may be necessary to remove modules or pc boards while the main unit is still operating. These are considered hot-plug applications. Such implementations require the control of current surges seen by the main power supply and the card being insert ...
Axxium Rackmount
... Whenever the Axxium Rackmount is “On,” there may be dangerous voltage present at the unit’s outlets. This is true because the unit’s battery supplies power even if the unit is not plugged into the wall outlet. The unit contains dangerous voltages. To reduce the risk of electric shock, install in a t ...
... Whenever the Axxium Rackmount is “On,” there may be dangerous voltage present at the unit’s outlets. This is true because the unit’s battery supplies power even if the unit is not plugged into the wall outlet. The unit contains dangerous voltages. To reduce the risk of electric shock, install in a t ...
P2030 Smart Grid Standard Text Submittal Form This text is
... layer (i.e. first byte sent by source application to last byte received by destination application). The transfer time includes the communications system latency (i.e. is technology and path dependent), and any required connection time (e.g. dial-up). Without these inclusions, there should not be a ...
... layer (i.e. first byte sent by source application to last byte received by destination application). The transfer time includes the communications system latency (i.e. is technology and path dependent), and any required connection time (e.g. dial-up). Without these inclusions, there should not be a ...
Sepam series 80 sales promotion package
... earth fault alarms. It shall be possible to customize the assignment of the signal LEDs. The display indication shall be in 2 languages Local for operations English for maintenance as a back up of local The Protection and Control unit shall include a keypad to allow to perform the following op ...
... earth fault alarms. It shall be possible to customize the assignment of the signal LEDs. The display indication shall be in 2 languages Local for operations English for maintenance as a back up of local The Protection and Control unit shall include a keypad to allow to perform the following op ...
Voltage and Voltage Range Voltage or "Rated Voltage" refers to the
... down and if you run at a higher than nominal voltage the fan will speed up. AC & DC Voltage Standard AC voltages in North America are 110, 115, 120V (standard household, outlet current) and 220, 230, 240V (standard household, large appliance current) Note that 110, 115 and 120V are considered equiva ...
... down and if you run at a higher than nominal voltage the fan will speed up. AC & DC Voltage Standard AC voltages in North America are 110, 115, 120V (standard household, outlet current) and 220, 230, 240V (standard household, large appliance current) Note that 110, 115 and 120V are considered equiva ...
Wire Antennas For Limited Space
... • Equal and flowing in the same direction on all conductors of balanced lines • Current flows lengthwise on the line – No cancellation of one current by another, because they’re in polarity ...
... • Equal and flowing in the same direction on all conductors of balanced lines • Current flows lengthwise on the line – No cancellation of one current by another, because they’re in polarity ...
10321064, 09221038, 09221127, 09221029
... for the energy sector of Bangladesh. Bangladesh is a developing and over populated country .For this reason the number of private car are increasing day by day in Dhaka city and most of the car in our country were driven by petroleum. Petroleum oil is not a natural resource of Bangladesh, so that ea ...
... for the energy sector of Bangladesh. Bangladesh is a developing and over populated country .For this reason the number of private car are increasing day by day in Dhaka city and most of the car in our country were driven by petroleum. Petroleum oil is not a natural resource of Bangladesh, so that ea ...
on the damper cage bars` currents calculation for salient pole large
... be obtained numerically by finite elements method but also is possible to be given analytically. If the analytical approach is considered to obtain the form factors that are necessary to calculate the self and mutual inductances, a permeance distribution curve along a pole pitch can be defined based ...
... be obtained numerically by finite elements method but also is possible to be given analytically. If the analytical approach is considered to obtain the form factors that are necessary to calculate the self and mutual inductances, a permeance distribution curve along a pole pitch can be defined based ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).