MAX17019 High-Input-Voltage Quad-Output Controller General Description Features
... makes it an excellent choice for automotive applications. The internal switching regulators include 5V synchronous MOSFETs that can be powered directly from a single Li+ cell or from the main 3.3V/5V power stages. Finally, the linear regulator is capable of sourcing and sinking 2A to support DDR ter ...
... makes it an excellent choice for automotive applications. The internal switching regulators include 5V synchronous MOSFETs that can be powered directly from a single Li+ cell or from the main 3.3V/5V power stages. Finally, the linear regulator is capable of sourcing and sinking 2A to support DDR ter ...
ORION 2.0: A Fast and Accurate NoC Power and Area Model for
... generations of high-end VLSI designs will operate in 10-20 GHz range with the communication between cores in Gbit/s [40]. This requires designers to work within a tight power budget. To aid designers in early stages of design, architectural power models were proposed for rough power estimations (see ...
... generations of high-end VLSI designs will operate in 10-20 GHz range with the communication between cores in Gbit/s [40]. This requires designers to work within a tight power budget. To aid designers in early stages of design, architectural power models were proposed for rough power estimations (see ...
Maximum power point tracking of a photovoltaic system utilizing an
... as wind, solar, biomass, and others, have been explored so that the military can reduce its reliance on fossil fuels and improve its operational range. One of the components to this effort is solar photovoltaic (PV) technology. The purpose of this thesis is to demonstrate the importance of using a m ...
... as wind, solar, biomass, and others, have been explored so that the military can reduce its reliance on fossil fuels and improve its operational range. One of the components to this effort is solar photovoltaic (PV) technology. The purpose of this thesis is to demonstrate the importance of using a m ...
Thesis-Reporttt-4
... the defects clarification was done by the service staff, which optically diagnose the faults and by hand monitored a transformer to remove the faults up to some extent [1]. As come out faults became more and the working demands of the electric power grid became more rigorous, the demand for automati ...
... the defects clarification was done by the service staff, which optically diagnose the faults and by hand monitored a transformer to remove the faults up to some extent [1]. As come out faults became more and the working demands of the electric power grid became more rigorous, the demand for automati ...
LF412-N 数据资料 dataSheet 下载
... allowed to exceed the negative supply as this will cause large currents to flow which can result in a destroyed unit. Exceeding the negative common-mode limit on either input will cause a reversal of the phase to the output and force the amplifier output to the corresponding high or low state. Excee ...
... allowed to exceed the negative supply as this will cause large currents to flow which can result in a destroyed unit. Exceeding the negative common-mode limit on either input will cause a reversal of the phase to the output and force the amplifier output to the corresponding high or low state. Excee ...
design, fabrication and simulations of
... Table 1. Simulation results for the natural frequency, fres, voltages, Vload , (peak) and power, Pload , delivered to the load resistance, Rload for three generator structures. In contrast to many micro-fabricated magnetic generator structures, the simulation results indicate that reasonable voltage ...
... Table 1. Simulation results for the natural frequency, fres, voltages, Vload , (peak) and power, Pload , delivered to the load resistance, Rload for three generator structures. In contrast to many micro-fabricated magnetic generator structures, the simulation results indicate that reasonable voltage ...
MARS User´s Guide
... the 5 way Smart Battery connecting lead of Moltech – part number: 629010). In the Appendices you can find a list of possible Smart Batteries. The modular setup of SBS MARS is a guideline for the devoloper and the user to configure and set up the System, as necessary. (fig. 2 and fig. 3) The buck-boo ...
... the 5 way Smart Battery connecting lead of Moltech – part number: 629010). In the Appendices you can find a list of possible Smart Batteries. The modular setup of SBS MARS is a guideline for the devoloper and the user to configure and set up the System, as necessary. (fig. 2 and fig. 3) The buck-boo ...
Lab – 1: Linear Solenoid Actuator
... The goal of this task is to measure the force profile of the solenoid at a given current. This is done by performing several measurements of the holding force at different plunger positions. Each force measurement is performed by pulling on the Lever Arm (see Figure 4) until the plunger breaks free ...
... The goal of this task is to measure the force profile of the solenoid at a given current. This is done by performing several measurements of the holding force at different plunger positions. Each force measurement is performed by pulling on the Lever Arm (see Figure 4) until the plunger breaks free ...
JPBD/LPBD Series Protected Battery Disconnects
... The LPBD series is ideal for outside plant, cell site, central office and co-location applications. The LPBD is available in wall mount, rack mount, custom and NEMA enclosure configurations in package sizes that require minimal space. In addition to the disconnect function the LPBD also provides ove ...
... The LPBD series is ideal for outside plant, cell site, central office and co-location applications. The LPBD is available in wall mount, rack mount, custom and NEMA enclosure configurations in package sizes that require minimal space. In addition to the disconnect function the LPBD also provides ove ...
MAX17019 High-Input-Voltage Quad
... LXB, LXC to GND....................................-1.0V to (VINBC + 0.3V) BSTB to GND...................................(VDD - 0.3V) to (VLXB + 6V) BSTC to GND..................................(VDD - 0.3V) to (VLXC + 6V) BSTA to GND...................................(VDD - 0.3V) to (VLXA + 6V) REF ...
... LXB, LXC to GND....................................-1.0V to (VINBC + 0.3V) BSTB to GND...................................(VDD - 0.3V) to (VLXB + 6V) BSTC to GND..................................(VDD - 0.3V) to (VLXC + 6V) BSTA to GND...................................(VDD - 0.3V) to (VLXA + 6V) REF ...
A Complete Electrical Hazard Classification
... Workplace, NFPA 70E, and relevant OSHA electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. This leaves a substantial gap in the management of electrical hazards in Research and D ...
... Workplace, NFPA 70E, and relevant OSHA electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. This leaves a substantial gap in the management of electrical hazards in Research and D ...
Build an Electromagnet Problem: How can I make a stronger magnet
... that statement. 10. From this experiment: What would be the strongest possible electromagnet you could make? By theory the strongest was the 172 coils 2 layers 3 nails; We used the stronger D batteries for the 86 coil 1 layer 3 nails, but the other data states otherwise. 11. From this experiment: Ho ...
... that statement. 10. From this experiment: What would be the strongest possible electromagnet you could make? By theory the strongest was the 172 coils 2 layers 3 nails; We used the stronger D batteries for the 86 coil 1 layer 3 nails, but the other data states otherwise. 11. From this experiment: Ho ...
Alarm Threshold Programmer Operation and Maintenance
... 50670, and 50690 Zero Volt Bench Top Ionizers. The Zero Volt Bench Top Ionizer’s default alarm sensitivity is set to ±20 Volts offset voltage (balance). With the use of the Alarm Threshold Programmer, the user can program the Zero Volt Bench Top Ionizer to alarm sensitivities of ±5 Volts, ±10 Volts, ...
... 50670, and 50690 Zero Volt Bench Top Ionizers. The Zero Volt Bench Top Ionizer’s default alarm sensitivity is set to ±20 Volts offset voltage (balance). With the use of the Alarm Threshold Programmer, the user can program the Zero Volt Bench Top Ionizer to alarm sensitivities of ±5 Volts, ±10 Volts, ...
HMC536LP2E - Hittite Microwave Corp.
... The HMC536LP2 & HMC536LP2E are DC to 6 GHz GaAs MMIC T/R switches in leadless 2x2 mm DFN LP2 surface mount packages with an exposed ground paddle. The switch is ideal for cellular, WiMAX, & WiBro access point and subscriber applications featuring low 0.6 dB insertion loss and high +54 dBm input IP3. ...
... The HMC536LP2 & HMC536LP2E are DC to 6 GHz GaAs MMIC T/R switches in leadless 2x2 mm DFN LP2 surface mount packages with an exposed ground paddle. The switch is ideal for cellular, WiMAX, & WiBro access point and subscriber applications featuring low 0.6 dB insertion loss and high +54 dBm input IP3. ...
HMMC-3122 DC-12 GHz Packaged High Efficiency Divide-by
... 2. Prescaler may exhibit this output signal under bias in the absence of an RF input signal. This condition may be eliminated by use of the Input dc offset technique described on page 4. 3. Fundamental of output square wave’s Fourier series. 4. Square wave amplitude calculated from Pout. ...
... 2. Prescaler may exhibit this output signal under bias in the absence of an RF input signal. This condition may be eliminated by use of the Input dc offset technique described on page 4. 3. Fundamental of output square wave’s Fourier series. 4. Square wave amplitude calculated from Pout. ...
Current flow controller - European Patent Office
... [0014] In such embodiments the current flow controller may include at least one additional main switching element, the or each additional main switching element being operatively connected between the third terminal and the corresponding additional terminal, the or each additional main switching ele ...
... [0014] In such embodiments the current flow controller may include at least one additional main switching element, the or each additional main switching element being operatively connected between the third terminal and the corresponding additional terminal, the or each additional main switching ele ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).