Datasheet - STMicroelectronics
... The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded. ...
... The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded. ...
Problem 2 - Roletech
... Bandwidth (BW) is inversely related to Q and gives an indication of the frequency response of a circuit. High-Q circuits have a narrow bandwidth, while low-Q circuits have a wide bandwidth. The bandwidth for the circuit is: ...
... Bandwidth (BW) is inversely related to Q and gives an indication of the frequency response of a circuit. High-Q circuits have a narrow bandwidth, while low-Q circuits have a wide bandwidth. The bandwidth for the circuit is: ...
FI3110651072
... Professor & HOD,Electrical & Electronics Engineering,N.B.K.R.I.ST,Andhrapradesh,India ...
... Professor & HOD,Electrical & Electronics Engineering,N.B.K.R.I.ST,Andhrapradesh,India ...
Electrical Narrative
... Lighting will be designed per IESNA standards and to the requirements of the RFP. The primary lamp source will be fluorescent utilizing energy saving electronic ballasts with a lamp color temperature of 4100K and Color Rendering Index (CRI) of 85 or higher. Ballast shall be energy saving high freque ...
... Lighting will be designed per IESNA standards and to the requirements of the RFP. The primary lamp source will be fluorescent utilizing energy saving electronic ballasts with a lamp color temperature of 4100K and Color Rendering Index (CRI) of 85 or higher. Ballast shall be energy saving high freque ...
Homework 4 Solutions Problem 1 1) Circuit schematic is shown as
... For region 1, the output voltage is between 0 and Vov, M1 and M2 both work at the linear region, the output impedance is very low, and the output current is small. Here, the upper voltage limit for region 1 is approximately 0.18V. For region 2, the output voltage is between Vov to 2Vov, M1 goes int ...
... For region 1, the output voltage is between 0 and Vov, M1 and M2 both work at the linear region, the output impedance is very low, and the output current is small. Here, the upper voltage limit for region 1 is approximately 0.18V. For region 2, the output voltage is between Vov to 2Vov, M1 goes int ...
01421-2.6 Basic Electrical Terms and Theories
... Course: 01.421 Agriculture Mechanics Technology ...
... Course: 01.421 Agriculture Mechanics Technology ...
ECE2262 Electric Circuits Chapter 6: Capacitance and Inductance
... RC OP-AMP CIRCUITS Integration and differentiation circuits ...
... RC OP-AMP CIRCUITS Integration and differentiation circuits ...
RB-Pol-266 200:1 Plastic Gearmotor 90 Degree Shaft
... This 200:1 gearbox with brushed DC motor has a low-current motor and provides power and speed that is comparable to an RC servo at a fraction of the cost. At 6 V, it has a free-run speed of 51 RPM and a stall torque of approximately 100 oz-in. This 200:1 plastic gearmotor (gearbox with brushed DC mo ...
... This 200:1 gearbox with brushed DC motor has a low-current motor and provides power and speed that is comparable to an RC servo at a fraction of the cost. At 6 V, it has a free-run speed of 51 RPM and a stall torque of approximately 100 oz-in. This 200:1 plastic gearmotor (gearbox with brushed DC mo ...
FETishizator V3.0
... will result in – positive half-wave – +400mVDC (4mA * 100Ω), while - negative half-wave – in 0VDC; all peak-to-peak AC - seen as DC-voltage. Therefore, we can presume a Null input voltage of +200mV as our design point. If the BF245A had 0V at its gate, it would show a drain current of 1mA, if we put ...
... will result in – positive half-wave – +400mVDC (4mA * 100Ω), while - negative half-wave – in 0VDC; all peak-to-peak AC - seen as DC-voltage. Therefore, we can presume a Null input voltage of +200mV as our design point. If the BF245A had 0V at its gate, it would show a drain current of 1mA, if we put ...
Experiment 4
... Transformers are arguably the most universally applied pieces of electrical equipment. As such, they range in size from miniature units weighing ounces to huge units weighing tons. All transformers, however, exhibit the same basic properties. When mutual induction is permitted between two coils or w ...
... Transformers are arguably the most universally applied pieces of electrical equipment. As such, they range in size from miniature units weighing ounces to huge units weighing tons. All transformers, however, exhibit the same basic properties. When mutual induction is permitted between two coils or w ...
Capacitors and RC circuits
... 1. Connect a cylindrical capacitor to the power supply in DC and apply a voltage between 5 and 10 V. 2. Disconnect the capacitor before turning the power supply off. (The capacitor should now have a charge.) 3. Connect two wires to the capacitor – one to each terminal. The wire should just be hangin ...
... 1. Connect a cylindrical capacitor to the power supply in DC and apply a voltage between 5 and 10 V. 2. Disconnect the capacitor before turning the power supply off. (The capacitor should now have a charge.) 3. Connect two wires to the capacitor – one to each terminal. The wire should just be hangin ...
SBF5089Z
... 3. USe a large ground pad area with many plated through-holes as shown. 4. We recommend 1 or 2 ounce copper. Measurement for this data sheet were made on a 31mil thick FR-4 board with 1 ounce copper on both sides. ...
... 3. USe a large ground pad area with many plated through-holes as shown. 4. We recommend 1 or 2 ounce copper. Measurement for this data sheet were made on a 31mil thick FR-4 board with 1 ounce copper on both sides. ...
Programmable SAE 800 Single-/Dual-/Triple- Tone Gong
... The current control insures that the output stage only conducts defined currents. In conjunction with the integrated thermal shutdown, this makes the configuration shortcircuit-protected within wide limits. Because of the absence of feedback the circuit is also extremely stable and therefore uncriti ...
... The current control insures that the output stage only conducts defined currents. In conjunction with the integrated thermal shutdown, this makes the configuration shortcircuit-protected within wide limits. Because of the absence of feedback the circuit is also extremely stable and therefore uncriti ...
Electric Generators and Motors
... Earth’s Magnetic Field. When a car drives through the Earth’s magnetic field, an emf is induced in its vertical 75.0-cmlong radio antenna. If the Earth’s field (5 x 10-5 T) points north with a dip angle of 45°, what is the maximum emf induced in the antenna and which direction(s) will the car be mo ...
... Earth’s Magnetic Field. When a car drives through the Earth’s magnetic field, an emf is induced in its vertical 75.0-cmlong radio antenna. If the Earth’s field (5 x 10-5 T) points north with a dip angle of 45°, what is the maximum emf induced in the antenna and which direction(s) will the car be mo ...
Harmonics in power system and metering
... type of connection as illustrated above in three phase systems. Thus the total power measured will also be different for the same harmonics in the system. ...
... type of connection as illustrated above in three phase systems. Thus the total power measured will also be different for the same harmonics in the system. ...
Operating Instructions
... In practice, many devices have soft breakdown, “punch through” or surface breakdown before the rated leakage current is reached. For these devices, exceeding the rated voltage established by the manufacturer may result in instant failure or in down grading of the blocking characteristics. Disc (puck ...
... In practice, many devices have soft breakdown, “punch through” or surface breakdown before the rated leakage current is reached. For these devices, exceeding the rated voltage established by the manufacturer may result in instant failure or in down grading of the blocking characteristics. Disc (puck ...
DIN-A-MITE B Spec Sheet - Watlow.com.sg | heaters
... • AC contactor: 24VAC ±10%, 120VAC +10/-25%, 240VAC +10/-25% @ 25mA max. per controlled leg • DC contactor: 4.5 to 32VDC: max. c urrent @ 4.5VDC is 6mA per leg. Add 2mA per LED used to the total current • Linear current: 4 to 20mA DC: loop-powered, control option F0 only (requires current source w ...
... • AC contactor: 24VAC ±10%, 120VAC +10/-25%, 240VAC +10/-25% @ 25mA max. per controlled leg • DC contactor: 4.5 to 32VDC: max. c urrent @ 4.5VDC is 6mA per leg. Add 2mA per LED used to the total current • Linear current: 4 to 20mA DC: loop-powered, control option F0 only (requires current source w ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).