
lightning safety guideline: results of an 8 year
... is greater than previously thought. The old recommended safe distance from the previous flash was 1-3 miles. New information suggests that a safe distance should be 6-8 miles (Lopez & Holle, National Severe Storm Center, 1998). Second, some 40% of cloud-to-ground lightnings are forked, with two or m ...
... is greater than previously thought. The old recommended safe distance from the previous flash was 1-3 miles. New information suggests that a safe distance should be 6-8 miles (Lopez & Holle, National Severe Storm Center, 1998). Second, some 40% of cloud-to-ground lightnings are forked, with two or m ...
RISE 101 - EcoSense Lighting
... 51. What is the lowest dimming level before RISE is turned off? a. RISE will dim smoothly down to <=5% measured light. 52. What is the lowest level RISE will turn on at? a. RISE will start up at <=5% measured light. 53. Is RISE compatible with DALI or DMX? a. RISE will be compatible with an interfa ...
... 51. What is the lowest dimming level before RISE is turned off? a. RISE will dim smoothly down to <=5% measured light. 52. What is the lowest level RISE will turn on at? a. RISE will start up at <=5% measured light. 53. Is RISE compatible with DALI or DMX? a. RISE will be compatible with an interfa ...
Extending Power Cable Life an Additional 40 Years
... addition to having an attractive cost profile, cable rejuvenation also saves time. At an industrial plant, it takes less than one day to inject even long lengths of medium voltage cables, and typically only a couple of hours for most cables. What is the cost of a failure in your plant? Many industri ...
... addition to having an attractive cost profile, cable rejuvenation also saves time. At an industrial plant, it takes less than one day to inject even long lengths of medium voltage cables, and typically only a couple of hours for most cables. What is the cost of a failure in your plant? Many industri ...
THE 12 VOLT DOCTOR`S PRACTICAL HANDBOOK
... = 3.6 Ohms of resistance. Adding the switch resistance in series with this lamp will more than double the total resistance, so that the current will be reduced to: 12 volt divided by 8.6 total Ohm = 1.4 Ampere which flow through switch and lamp. This lamp will therefore hardly glow at all. And anoth ...
... = 3.6 Ohms of resistance. Adding the switch resistance in series with this lamp will more than double the total resistance, so that the current will be reduced to: 12 volt divided by 8.6 total Ohm = 1.4 Ampere which flow through switch and lamp. This lamp will therefore hardly glow at all. And anoth ...
MT-DB-X4 User Guide November 5, 2014
... eliminating the voltage drop across the diode, which can be useful for battery applications. Note that when the diode is shorted, reversepolarity protection is disabled, and J6 should be disconnected to prevent Vbus current from flowing into Vin. Vin voltage can be measured on pin B3 by connecti ...
... eliminating the voltage drop across the diode, which can be useful for battery applications. Note that when the diode is shorted, reversepolarity protection is disabled, and J6 should be disconnected to prevent Vbus current from flowing into Vin. Vin voltage can be measured on pin B3 by connecti ...
Evaluates: MAX1566/MAX1567 MAX1567 Step-Up Main Evaluation Kit General Description Features
... The outputs OUT3+ and OUT3- are for driving a series of white LEDs for display backlighting. The EV kit comes with four surface-mount white LEDs installed and is configured to drive the LEDs at a regulated 20mA. To protect against an open LED string, the overvoltage protection limits the maximum out ...
... The outputs OUT3+ and OUT3- are for driving a series of white LEDs for display backlighting. The EV kit comes with four surface-mount white LEDs installed and is configured to drive the LEDs at a regulated 20mA. To protect against an open LED string, the overvoltage protection limits the maximum out ...
Installation Instructions
... The most common form of electrical system for vehicles consists of a battery an alternator and electric starter motor. Power to the electrical components is made from the battery through a master Switch that isolates the entire vehicle electrical system. Battery power is then directed to secondary s ...
... The most common form of electrical system for vehicles consists of a battery an alternator and electric starter motor. Power to the electrical components is made from the battery through a master Switch that isolates the entire vehicle electrical system. Battery power is then directed to secondary s ...
High Pressure Sodium Lamps
... temperature and pressure build gradually, causing metal vapors to enter into the arc and release light energy. Starting the arc sometimes takes a few seconds, and the warm-up period is generally about four minutes. During this time, the lamp exhibits different colors as more sodium vapor, enters the ...
... temperature and pressure build gradually, causing metal vapors to enter into the arc and release light energy. Starting the arc sometimes takes a few seconds, and the warm-up period is generally about four minutes. During this time, the lamp exhibits different colors as more sodium vapor, enters the ...
OPERATION and MAINTENANCE INSTRUCTION MANUAL
... WARNING: This device has been tested and found to comply with the emissions requirements of IEC 606011-2:2001-09. These requirements provide reasonable protection against harmful electromagnetic interference in a typical medical installation. However, high levels of radio-frequency (RF) emissions fr ...
... WARNING: This device has been tested and found to comply with the emissions requirements of IEC 606011-2:2001-09. These requirements provide reasonable protection against harmful electromagnetic interference in a typical medical installation. However, high levels of radio-frequency (RF) emissions fr ...
S280-75-2
... switches and indicators used for manual operation and service are grouped on the bottom, light portion of the panel. The front panel is backed by a printed-circuit tie board which supports and interfaces the plug-in circuit boards with other related circuit components (Figure 3). Program-altering, r ...
... switches and indicators used for manual operation and service are grouped on the bottom, light portion of the panel. The front panel is backed by a printed-circuit tie board which supports and interfaces the plug-in circuit boards with other related circuit components (Figure 3). Program-altering, r ...
3c-emissions compliance testing LISN 2008-2009
... the Line and Neutral networks. The single phase LISN is sometimes referred to as a ‘V’ network as shown in Figure 3b. The levels of conducted emissions are measured as a voltage at the output of the LISN and are a function of the EUT impedance (source impedance) and the LISN impedance (load impedanc ...
... the Line and Neutral networks. The single phase LISN is sometimes referred to as a ‘V’ network as shown in Figure 3b. The levels of conducted emissions are measured as a voltage at the output of the LISN and are a function of the EUT impedance (source impedance) and the LISN impedance (load impedanc ...
WAYGOOD CH18 WEB.indd
... worldwide, introduce bans on their manufacture and sale in the interests of energy conservation. The European Union, for example, has banned the sale of all GLS lamps since September, 2012. This ban, however, doesn’t extend to those incandescent lamps manufactured for special purposes, such as those ...
... worldwide, introduce bans on their manufacture and sale in the interests of energy conservation. The European Union, for example, has banned the sale of all GLS lamps since September, 2012. This ban, however, doesn’t extend to those incandescent lamps manufactured for special purposes, such as those ...
Motor controller guide
... In general, the purposes of a motor control system are to take a constant voltage input and to translate desired high-level motor commands. An example would be taking the command, “spin the motor at 50% of its maximum speed in the forward direction,” and translating it to the electrical commands the ...
... In general, the purposes of a motor control system are to take a constant voltage input and to translate desired high-level motor commands. An example would be taking the command, “spin the motor at 50% of its maximum speed in the forward direction,” and translating it to the electrical commands the ...
TJA 1050 CAN High-Speed Transceiver
... The high-speed mode is the normal operating mode and is selected by connecting pin "S" to ground. Due to an internal pull-down function (see Figure 2.2) it is the default mode if pin "S" is unconnected. In this mode the bus output signals are switched as fast as possible with a fixed slope. It is th ...
... The high-speed mode is the normal operating mode and is selected by connecting pin "S" to ground. Due to an internal pull-down function (see Figure 2.2) it is the default mode if pin "S" is unconnected. In this mode the bus output signals are switched as fast as possible with a fixed slope. It is th ...
Sabertooth 2×32 - Dimension Engineering
... Sabertooth 2x32 can be used with a suitably sized power supply. Power supplies used with a Sabertooth 2x32 should have output voltages between 7V and 30V. It is important to make sure the power supply being used can produce enough current for the load. Power Supply mode is selected by setting DIP sw ...
... Sabertooth 2x32 can be used with a suitably sized power supply. Power supplies used with a Sabertooth 2x32 should have output voltages between 7V and 30V. It is important to make sure the power supply being used can produce enough current for the load. Power Supply mode is selected by setting DIP sw ...
Specification Number: 16440-1
... E. The complete assembly shall be constructed in accordance with applicable provisions of ANSI / IEEE C37.20.3-1987 and the minimum construction standards of the manufacturers of the major components such as power fuses or potential transformers. Provide adequate space for fuse handling when applica ...
... E. The complete assembly shall be constructed in accordance with applicable provisions of ANSI / IEEE C37.20.3-1987 and the minimum construction standards of the manufacturers of the major components such as power fuses or potential transformers. Provide adequate space for fuse handling when applica ...
GENERAL SPECIFICATION FOR VARIABLE SPEED DRIVES (VSDS).
... The Contractor shall have a permanent representative office with a trained and skilled support staff, in the country where the goods are delivered, in order to prove his commitment for local support and to provide a channel for communication. The local representatives shall be easily accessible and ...
... The Contractor shall have a permanent representative office with a trained and skilled support staff, in the country where the goods are delivered, in order to prove his commitment for local support and to provide a channel for communication. The local representatives shall be easily accessible and ...
guide specification
... suppressor network. The suppressor network shall be fused in order to minimize damage to the UPS in the event that input transients exceed the rating of the suppression network. ...
... suppressor network. The suppressor network shall be fused in order to minimize damage to the UPS in the event that input transients exceed the rating of the suppression network. ...
Selecting E7/P7/F7 Drives for Single-Phase Input
... Thus, strict input voltage of 240V(480Vac) +10 to -5% at 60Hz applies with single-phase use! Note: Wire input using terminals L1(R) and L2(S) to accommodate units that incorporate AC fans and soft-charge circuits ...
... Thus, strict input voltage of 240V(480Vac) +10 to -5% at 60Hz applies with single-phase use! Note: Wire input using terminals L1(R) and L2(S) to accommodate units that incorporate AC fans and soft-charge circuits ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).