Instruction Manual
... necessary, a capacitor can be inserted in the signal path to block the DC offset voltage. (The capacitor value is calculated in each individual case to allow for source/load impedance values and the desired low frequency roll-off. Make sure only to use high quality audio-grade capacitors). If a tota ...
... necessary, a capacitor can be inserted in the signal path to block the DC offset voltage. (The capacitor value is calculated in each individual case to allow for source/load impedance values and the desired low frequency roll-off. Make sure only to use high quality audio-grade capacitors). If a tota ...
TS Series: 5 kW to 45 kW - Magna
... Certain applications require floating the output voltage to values beyond the power supply’s standard isolation rating. Magna-Power Electronics High Isolation Output option (+ISO) enables any TS Series, MS Series, or MT Series model with a peak output voltage rating of 250 Vdc through 1000 Vdc to be ...
... Certain applications require floating the output voltage to values beyond the power supply’s standard isolation rating. Magna-Power Electronics High Isolation Output option (+ISO) enables any TS Series, MS Series, or MT Series model with a peak output voltage rating of 250 Vdc through 1000 Vdc to be ...
1A Step-Down Voltage Regulator
... National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2 ...
... National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2 ...
RTL035N03
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
Poloidal Field Power Supply Systems for the HT
... during the plasma initiation and current ramp-up, its parameters are shown in Table 8. Since this DC circuit breaker system is subjected to very frequent operation, both the electrical and mechanical life of the system are of prime importance. In the plasma initiation phase, each PF circuit must con ...
... during the plasma initiation and current ramp-up, its parameters are shown in Table 8. Since this DC circuit breaker system is subjected to very frequent operation, both the electrical and mechanical life of the system are of prime importance. In the plasma initiation phase, each PF circuit must con ...
Techniques For Implementing A Positive And Negative Output
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
... applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask ...
Power factor in transmission system
... or inductors, voltage and current waveforms are not in step (or not in phase), thus result in a time difference between the current and voltage waveforms. Thus have energy storage in the loads which returns to the source and is not available to do work at the load. A circuit with a low power facto ...
... or inductors, voltage and current waveforms are not in step (or not in phase), thus result in a time difference between the current and voltage waveforms. Thus have energy storage in the loads which returns to the source and is not available to do work at the load. A circuit with a low power facto ...
Modeling and Simulation of Three-Phase Voltage Source Inverter
... voltages VDC and - VDC can be switched. As shown in Fig. 2 the voltage vectors which are generated by the inverter resulted in only seven different voltage vectors because V0 and V7 produce the same zero voltage vector (V0 = V7), that means a three-phase two-level voltage source converter can delive ...
... voltages VDC and - VDC can be switched. As shown in Fig. 2 the voltage vectors which are generated by the inverter resulted in only seven different voltage vectors because V0 and V7 produce the same zero voltage vector (V0 = V7), that means a three-phase two-level voltage source converter can delive ...
3A, 52kHz, Step-Down Switching Regulator LM2576
... All circuits of this series are capable of driving a 3.0A load with excellent line and load regulation. These devices are available in fixed output voltages of 3.3V, 5.0V, 12V and an adjustable output version. These regulators were designed to minimize the number of external components to simplify t ...
... All circuits of this series are capable of driving a 3.0A load with excellent line and load regulation. These devices are available in fixed output voltages of 3.3V, 5.0V, 12V and an adjustable output version. These regulators were designed to minimize the number of external components to simplify t ...
FSL156MRIN Green-Mode Fairchild Power Switch (FPS™) FSL156MRIN — Green-Mode Fair
... 4.1 Overload Protection (OLP): Overload is defined as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can ...
... 4.1 Overload Protection (OLP): Overload is defined as the load current exceeding its normal level due to an unexpected abnormal event. In this situation, the protection circuit should trigger to protect the SMPS. However, even when the SMPS is in normal operation, the overload protection circuit can ...
UC2841数据资料 dataSheet 下载
... the earlier UC1840 devices. While still optimized for highly-efficient bootstrapped primary-side operation in forward or flyback power converters, the UC1841 is equally adept in implementing both low and high voltage input DC to DC converters. Important performance features include a low-current sta ...
... the earlier UC1840 devices. While still optimized for highly-efficient bootstrapped primary-side operation in forward or flyback power converters, the UC1841 is equally adept in implementing both low and high voltage input DC to DC converters. Important performance features include a low-current sta ...
the use of protective earth as a distributor of fields and radiation
... through the PE-wire as an electrical field to the air. If there is no active source, there will not be any electric field from the passive source ...
... through the PE-wire as an electrical field to the air. If there is no active source, there will not be any electric field from the passive source ...
50 MHz Amplifier
... Heater Volts: 13.8 V +/- 5% AC or DC at 2.8 Amps. I will not go into a description of the POWER SUPPLY but I will list a few important points: Screen Regulation is crucial for good IMD. I achieve less than 6V difference in screen volts under full Key-Down conditions at 50mA total screen current. I u ...
... Heater Volts: 13.8 V +/- 5% AC or DC at 2.8 Amps. I will not go into a description of the POWER SUPPLY but I will list a few important points: Screen Regulation is crucial for good IMD. I achieve less than 6V difference in screen volts under full Key-Down conditions at 50mA total screen current. I u ...
PORTABLE DENTAL X
... 4. The battery DC socket connected to the DC IN socket on the back of the machine, and confirmed that the back of the charging LED is red 5. Battery charging will be used machine’s accessories dedicated charger. 6. The battery is a consumable item, with the passage of time; the time of usage will be ...
... 4. The battery DC socket connected to the DC IN socket on the back of the machine, and confirmed that the back of the charging LED is red 5. Battery charging will be used machine’s accessories dedicated charger. 6. The battery is a consumable item, with the passage of time; the time of usage will be ...
AMERITRON AL-811H
... amplifier that operates reliably from 160 through15 meters. The AL811H uses four 811A tubes in a class AB2 grounded grid circuit. Heavy duty power supply and RF components provide long service for components. The AL-811H/HY is shipped factory wired for 120 volt, 50/60 Hz power mains. The AL-811HX/HY ...
... amplifier that operates reliably from 160 through15 meters. The AL811H uses four 811A tubes in a class AB2 grounded grid circuit. Heavy duty power supply and RF components provide long service for components. The AL-811H/HY is shipped factory wired for 120 volt, 50/60 Hz power mains. The AL-811HX/HY ...
VIPer100 THE MOST ADVANCED MONLITHIC SOLUTION FOR
... In case of an abnormal condition where the auxiliary winding is unable to provide the low voltage supply current to the VDD pin (i.e. short circuit on the output of the converter), the external capacitor discharges itself down to the low threshold voltage VDDoff of the UVLO logic, and the device goe ...
... In case of an abnormal condition where the auxiliary winding is unable to provide the low voltage supply current to the VDD pin (i.e. short circuit on the output of the converter), the external capacitor discharges itself down to the low threshold voltage VDDoff of the UVLO logic, and the device goe ...
ameritron al-811h instruction manual
... amplifier that operates reliably from 160 through15 meters. The AL811H uses four 811A tubes in a class AB2 grounded grid circuit. Heavy duty power supply and RF components provide long service for components. The AL-811H/HY is shipped factory wired for 120 volt, 50/60 Hz power mains. The AL-811HX/HY ...
... amplifier that operates reliably from 160 through15 meters. The AL811H uses four 811A tubes in a class AB2 grounded grid circuit. Heavy duty power supply and RF components provide long service for components. The AL-811H/HY is shipped factory wired for 120 volt, 50/60 Hz power mains. The AL-811HX/HY ...
DMACC - Ind Maint - ELEM 575
... Learn about electrical safety concerns, with emphasis on lock out tag out procedures. Learn basic electrical theory, voltage, amps, resistance, series and parallel circuits. Learn electrical symbols and schematics, wiring and distribution. Use ladder diagrams and control devices to implement practic ...
... Learn about electrical safety concerns, with emphasis on lock out tag out procedures. Learn basic electrical theory, voltage, amps, resistance, series and parallel circuits. Learn electrical symbols and schematics, wiring and distribution. Use ladder diagrams and control devices to implement practic ...
Engineering Challenges in Wind Turbine Design
... • Post-fault dynamics can result in loss of synchronism and tripping • Wind plants with power electronic enabled WTGs can be more stable (than conventional synchronous generators.) ...
... • Post-fault dynamics can result in loss of synchronism and tripping • Wind plants with power electronic enabled WTGs can be more stable (than conventional synchronous generators.) ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).