STEVAL-IPE010V1
... STPMS1 devices, but it can also be used as a starting point to design a Class 1 meter for 2 to 4wire power line systems using delta or wye service. The STPMC1 is a metering ASSP implemented through an advanced 0.35 µm BCD6 technology. The STPMS1 is an ASSP designed as a building block for single or ...
... STPMS1 devices, but it can also be used as a starting point to design a Class 1 meter for 2 to 4wire power line systems using delta or wye service. The STPMC1 is a metering ASSP implemented through an advanced 0.35 µm BCD6 technology. The STPMS1 is an ASSP designed as a building block for single or ...
DC Circuits
... component and the entry side is at a higher potential. The other side is negative (-V) since it is at a lower potential. The side of a battery or power supply (active circuit component) where the current enters is negative and the other side is positive (meaning that the current gains energy as it p ...
... component and the entry side is at a higher potential. The other side is negative (-V) since it is at a lower potential. The side of a battery or power supply (active circuit component) where the current enters is negative and the other side is positive (meaning that the current gains energy as it p ...
Physical chemistry
... the help of the standard potential. For the reaction of hydrogen with oxygen, this is about 1.23 V. However, real fuel cells rarely achieve a no-load voltage greater than 1.0 V. This is caused by the internal resistance or an inadequate supply of hydrogen to the electrodes. The voltage is independen ...
... the help of the standard potential. For the reaction of hydrogen with oxygen, this is about 1.23 V. However, real fuel cells rarely achieve a no-load voltage greater than 1.0 V. This is caused by the internal resistance or an inadequate supply of hydrogen to the electrodes. The voltage is independen ...
722.6 Failure to Upshift
... see the problem. Figure 4 shows a good signal from both N2 and N3 speed sensors. Remember that both speed sensors share a common 6 volts and ground provided by the TCM. Each speed sensor has its own signal return wire to the TCM. Grounding the scope to battery ground (reference to battery ground) al ...
... see the problem. Figure 4 shows a good signal from both N2 and N3 speed sensors. Remember that both speed sensors share a common 6 volts and ground provided by the TCM. Each speed sensor has its own signal return wire to the TCM. Grounding the scope to battery ground (reference to battery ground) al ...
DS2478 PWM valve driver
... valve driver to fail as a short circuit. This will apply the full power supply voltage to the connected load. SIGNAL SELECT (EX-A) JUMPER: When the valve driver is supplied with the internal command potentiometer, it will also include a signal source select jumper. This jumper is a three position pi ...
... valve driver to fail as a short circuit. This will apply the full power supply voltage to the connected load. SIGNAL SELECT (EX-A) JUMPER: When the valve driver is supplied with the internal command potentiometer, it will also include a signal source select jumper. This jumper is a three position pi ...
SNOW GLOW® Single Vent Light Kit Installation Instructions Your
... tapped into. Other model machines such as Ski-Doo have voltage regulators difficult to access. You should tap the voltage regulator white wires into the solid yellow and yellow with black tracer wires coming out of the engine harness on Ski-Doo machines. Never tap into a yellow with red line wire to ...
... tapped into. Other model machines such as Ski-Doo have voltage regulators difficult to access. You should tap the voltage regulator white wires into the solid yellow and yellow with black tracer wires coming out of the engine harness on Ski-Doo machines. Never tap into a yellow with red line wire to ...
Instruction Manual
... Under this mode, the - Master Output Terminal is shorted with the - Slave Output Terminal while the + Master Output Terminal is shorted with the + Slave Output Terminal automatically. This parallel output is generated from the + Master Output Terminal and the -Master Output Terminal (or Slave Output ...
... Under this mode, the - Master Output Terminal is shorted with the - Slave Output Terminal while the + Master Output Terminal is shorted with the + Slave Output Terminal automatically. This parallel output is generated from the + Master Output Terminal and the -Master Output Terminal (or Slave Output ...
AN5082, MagniV in 24 V Applications
... Freescale S12 MagniV portfolio simplifies system design and reduces time to market with integrated mixed-signal microcontrollers (MCUs) for automotive and industrial applications. Offering single-die solutions, the S12 MagniV MCUs are complete system-in-package (SiP) solutions built on proven S12 te ...
... Freescale S12 MagniV portfolio simplifies system design and reduces time to market with integrated mixed-signal microcontrollers (MCUs) for automotive and industrial applications. Offering single-die solutions, the S12 MagniV MCUs are complete system-in-package (SiP) solutions built on proven S12 te ...
TPS63000-Q1 数据资料 dataSheet 下载
... The TPS63000 devices provide a power supply solution for products powered by either a two-cell or three-cell alkaline, NiCd or NiMH battery, or a one-cell Li-Ion or Li-polymer battery. Output currents can go as high as 1200 mA while using a single-cell Li-Ion or Li-Polymer battery, and discharge it ...
... The TPS63000 devices provide a power supply solution for products powered by either a two-cell or three-cell alkaline, NiCd or NiMH battery, or a one-cell Li-Ion or Li-polymer battery. Output currents can go as high as 1200 mA while using a single-cell Li-Ion or Li-Polymer battery, and discharge it ...
MAX4506/MAX4507 Fault-Protected, High-Voltage Signal-Line Protectors General Description
... The MAX4506/MAX4507 protect other integrated circuits connected to its output from latching up. Latchup is caused by parasitic SCR(s) within the IC turning on, and can occur when the supply voltage applied to the IC exceeds the specified operating range. Latchup can also occur when signal voltage is ...
... The MAX4506/MAX4507 protect other integrated circuits connected to its output from latching up. Latchup is caused by parasitic SCR(s) within the IC turning on, and can occur when the supply voltage applied to the IC exceeds the specified operating range. Latchup can also occur when signal voltage is ...
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
... MR2 Evidence of developing, maintaining and implementing procedures as required in requirement R2 exists. Evidence may include dated, in effect procedures including version history, consultation documentation, operator logs and data files. MR3 Evidence of operating as required in requirement R3 exis ...
... MR2 Evidence of developing, maintaining and implementing procedures as required in requirement R2 exists. Evidence may include dated, in effect procedures including version history, consultation documentation, operator logs and data files. MR3 Evidence of operating as required in requirement R3 exis ...
Technical Note: Using an Optimized Transfer Approach
... idea behind the method is that the best way to prevent transformer saturation when a primary source failure is detected is to delay for a period of time before turning on the alternate source. The length of the delay is determined by the source phase difference, and the transfer is completed by all ...
... idea behind the method is that the best way to prevent transformer saturation when a primary source failure is detected is to delay for a period of time before turning on the alternate source. The length of the delay is determined by the source phase difference, and the transfer is completed by all ...
Ultra-miniature, Highly Sensitive SPDT Relay for Signal
... · Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other ...
... · Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other ...
MAX8867/MAX8868 Low-Noise, Low-Dropout, 150mA Linear Regulators in SOT23 _______________General Description
... low-quiescent-current linear regulators designed primarily for battery-powered applications. The parts are available with preset output voltages varying from 2.5V to 5.0V in 100mV increments. These devices can supply loads up to 150mA. As illustrated in Figure 1, the MAX8867/MAX8868 consist of a 1.2 ...
... low-quiescent-current linear regulators designed primarily for battery-powered applications. The parts are available with preset output voltages varying from 2.5V to 5.0V in 100mV increments. These devices can supply loads up to 150mA. As illustrated in Figure 1, the MAX8867/MAX8868 consist of a 1.2 ...
Alternating current
Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).