Application Note 600V CoolMOS™ P6 01_00
... such as a 100 mΩ/600 V part in a TO-220 package. Furthermore it allows making parts with very low capacitances for a given RDS(on) as the silicon chip is much smaller than for a conventional power MOSFET. Both input and high voltage level of the output capacitance scale directly with the chip size, ...
... such as a 100 mΩ/600 V part in a TO-220 package. Furthermore it allows making parts with very low capacitances for a given RDS(on) as the silicon chip is much smaller than for a conventional power MOSFET. Both input and high voltage level of the output capacitance scale directly with the chip size, ...
ADS5270 数据资料 dataSheet 下载
... Analog Input Common-Mode Range Differential Full-Scale Input Voltage Range ...
... Analog Input Common-Mode Range Differential Full-Scale Input Voltage Range ...
TPS61196 6-String 400-mA WLED Driver w
... required by the LED string with the largest forward voltage drop plus the minimum required voltage at that string's IFB pin, thereby optimizing the driver's efficiency. Its switching frequency is programmed by an external resistor from 100kHz to 800kHz. The TPS61196 supports direct PWM brightness di ...
... required by the LED string with the largest forward voltage drop plus the minimum required voltage at that string's IFB pin, thereby optimizing the driver's efficiency. Its switching frequency is programmed by an external resistor from 100kHz to 800kHz. The TPS61196 supports direct PWM brightness di ...
ADM6710 数据手册DataSheet 下载
... The RESET output asserts low if a monitored INx voltage drops below its voltage threshold. Once all voltages rise above the selected threshold level, the reset signal remains low for the reset timeout period (200 ms typical). The reset output is open drain with a weak internal pull-up to the monitor ...
... The RESET output asserts low if a monitored INx voltage drops below its voltage threshold. Once all voltages rise above the selected threshold level, the reset signal remains low for the reset timeout period (200 ms typical). The reset output is open drain with a weak internal pull-up to the monitor ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... With advances in switch technology that have made them suitable for the voltage and power levels necessary for power applications, power electronic switches can be used to build devices that could sustain repeated operations with high reliability and without wearing out [17]. There are 2 main types ...
... With advances in switch technology that have made them suitable for the voltage and power levels necessary for power applications, power electronic switches can be used to build devices that could sustain repeated operations with high reliability and without wearing out [17]. There are 2 main types ...
Section 4: Sensor Signal Conditioning
... This chapter of the book deals with various sensors and associated signal-conditioning circuitry involving the use of op amps and in-amps. While the topic is generally very broad, the focus is to concentrate on circuit and signal processing applications of sensors rather than the details of the actu ...
... This chapter of the book deals with various sensors and associated signal-conditioning circuitry involving the use of op amps and in-amps. While the topic is generally very broad, the focus is to concentrate on circuit and signal processing applications of sensors rather than the details of the actu ...
Designing an electronic readout for a directional Lim, Choon Wee.
... unconventional operational theater. Today, there are such systems to localize snipers, but they are bulky, heavy and do not employ networking, which can greatly improve the performance in terms of accuracy and reliability. Hence, there is a need to design a system that is small, compact, distributed ...
... unconventional operational theater. Today, there are such systems to localize snipers, but they are bulky, heavy and do not employ networking, which can greatly improve the performance in terms of accuracy and reliability. Hence, there is a need to design a system that is small, compact, distributed ...
ATTACHMENT C Solar PV Standard Plan – Simplified BCM 6807
... SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a system AC inverter output rating of 10kW on the roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to the load side of a single-phase AC service pane ...
... SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems not exceeding a system AC inverter output rating of 10kW on the roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to the load side of a single-phase AC service pane ...
The phasor current is
... Phasor Diagrams – notes • Phasor lengths on diagram generally not to scale • They may not even share the same units • Phasor lengths are generally labeled on the diagram ...
... Phasor Diagrams – notes • Phasor lengths on diagram generally not to scale • They may not even share the same units • Phasor lengths are generally labeled on the diagram ...
Calibration Of Oscilloscopes
... section 7.2). For digital oscilloscopes, the amplitude decrease at the cut-off frequency is more significant (cp. section 3.3.4). Thus, the assumption of a Gaussian low pass filter characteristic defines the worst case. A precise determination of Sr is obtained by deviating the frequency response a ...
... section 7.2). For digital oscilloscopes, the amplitude decrease at the cut-off frequency is more significant (cp. section 3.3.4). Thus, the assumption of a Gaussian low pass filter characteristic defines the worst case. A precise determination of Sr is obtained by deviating the frequency response a ...
MAX14781E Half-Duplex RS-485 Transceiver with Polarity Correction General Description
... RS-485 transceiver features integrated automatic polarity correction to ensure that miswired A and B lines are autonomously corrected, simplifying equipment and network installation. The MAX14781E includes slew-rate limited drivers that minimize EMI, allowing for error-free data transmission up to 3 ...
... RS-485 transceiver features integrated automatic polarity correction to ensure that miswired A and B lines are autonomously corrected, simplifying equipment and network installation. The MAX14781E includes slew-rate limited drivers that minimize EMI, allowing for error-free data transmission up to 3 ...
LT3021/LT3021-1.2/ LT3021-1.5/LT3021-1.8
... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LT3021 regulators are tested and specified under pulse load cond ...
... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LT3021 regulators are tested and specified under pulse load cond ...
BD95602MUV
... ON resistance of output stage when High, it is 2Ω and when Low, it is 0.5Ω drive Low-side FET gate with the high pace. This is the output pin for 3.3V/50mA linear regulator (5V/3.3V (total 50mA)). Please connect 10µF capacitor which characteristic is more than X5R near the pin. This is the output pi ...
... ON resistance of output stage when High, it is 2Ω and when Low, it is 0.5Ω drive Low-side FET gate with the high pace. This is the output pin for 3.3V/50mA linear regulator (5V/3.3V (total 50mA)). Please connect 10µF capacitor which characteristic is more than X5R near the pin. This is the output pi ...
user`s manual
... 4-1 Point-To-Point Network (Analog Mode).....................................................................................4-5 4-2 Model 352 SLDC and Model 344 Connections (Analog Mode).....................................................4-6 4-3 Multi-Drop Network (Digital Mode) .................. ...
... 4-1 Point-To-Point Network (Analog Mode).....................................................................................4-5 4-2 Model 352 SLDC and Model 344 Connections (Analog Mode).....................................................4-6 4-3 Multi-Drop Network (Digital Mode) .................. ...
ADC0803, ADC0804 8-Bit, Microprocessor-Compatible, A/D Features Converters
... NOTES: 2. All voltages are measured with respect to GND, unless otherwise specified. The separate AGND point should always be wired to the DGND, being careful to avoid ground loops. 3. For VIN(-) ≥ VIN(+) the digital output code will be 0000 0000. Two on-chip diodes are tied to each analog input (se ...
... NOTES: 2. All voltages are measured with respect to GND, unless otherwise specified. The separate AGND point should always be wired to the DGND, being careful to avoid ground loops. 3. For VIN(-) ≥ VIN(+) the digital output code will be 0000 0000. Two on-chip diodes are tied to each analog input (se ...
Make a Delta-Sigma Converter Using a Microcontroller`s
... the output of the comparator (CMCON<6>). The firmware drives the D/A Converter output at RA3. The digital filter is implemented with two counters. ...
... the output of the comparator (CMCON<6>). The firmware drives the D/A Converter output at RA3. The digital filter is implemented with two counters. ...