74AHC1G66; 74AHCT1G66 1. General description Single-pole single-throw analog switch
... At supply voltages approaching 2 V, the analog switch ON resistance becomes extremely non-linear. Therefore it is recommended that these devices be used to transmit digital signals only, when using this supply voltage. ...
... At supply voltages approaching 2 V, the analog switch ON resistance becomes extremely non-linear. Therefore it is recommended that these devices be used to transmit digital signals only, when using this supply voltage. ...
FEATURES
... The SN74GTLPH1627 is a high-drive, 18-bit bus transceiver that provides LVTTL-to-GTLP and GTLP-to-LVTTL signal-level translation. The device allows for transparent and latched modes of data transfer. Additionally, with the use of the clock-mode select (CMS) input, the device can be used in source-sy ...
... The SN74GTLPH1627 is a high-drive, 18-bit bus transceiver that provides LVTTL-to-GTLP and GTLP-to-LVTTL signal-level translation. The device allows for transparent and latched modes of data transfer. Additionally, with the use of the clock-mode select (CMS) input, the device can be used in source-sy ...
Practical Electronics for Inventors
... totally lost interest in the subject or may have missed the “big picture,” confused by details and formulas. Practical Electronics for Inventors does not have this effect on the reader. Each chapter is broken up into sections with the essential practical information listed first. A typical chapteron ...
... totally lost interest in the subject or may have missed the “big picture,” confused by details and formulas. Practical Electronics for Inventors does not have this effect on the reader. Each chapter is broken up into sections with the essential practical information listed first. A typical chapteron ...
Some Transistors Stuff, Analog-to-Digital
... • In the totem pole arrangement, one guarantees that one of the two transistors is on and the other is off – giving a low-resistance connection to high or low as the case may be. • If we arrange for a third possibility that both transistors are off, then there is a high resistance between the output ...
... • In the totem pole arrangement, one guarantees that one of the two transistors is on and the other is off – giving a low-resistance connection to high or low as the case may be. • If we arrange for a third possibility that both transistors are off, then there is a high resistance between the output ...
Episode 126 - Teaching Advanced Physics
... Before showing students this demonstration, they should be aware of current as a flow of charge in a circuit and have tackled some of the problems involving the calculation of charge and the use of Q = I t. They might be shown initially what happens when the capacitor is charged without changing the ...
... Before showing students this demonstration, they should be aware of current as a flow of charge in a circuit and have tackled some of the problems involving the calculation of charge and the use of Q = I t. They might be shown initially what happens when the capacitor is charged without changing the ...
AD5100 数据手册DataSheet 下载
... 30 V. One application where this 30 V capability is useful is electronic media-oriented systems transport (eMOST) diagnostic circuits. ...
... 30 V. One application where this 30 V capability is useful is electronic media-oriented systems transport (eMOST) diagnostic circuits. ...
Platform Designer User Guide
... application requirements, by adding an external analog and sense control IC (ASC) to the Platform Manager 2. Each of the ASCs provides additional monitor and control of up to ten voltage rails, two temperature sensors and two current sensors. The overall platform management algorithm that uses the i ...
... application requirements, by adding an external analog and sense control IC (ASC) to the Platform Manager 2. Each of the ASCs provides additional monitor and control of up to ten voltage rails, two temperature sensors and two current sensors. The overall platform management algorithm that uses the i ...
WATTrouter M - user manual - SOLAR controls sro
... If the power output of the PV-plant decreases, or if another load - not connected to the WATTrouter device is switched on, the switched (active) outputs are disconnected - again according to preset priorities but in reverse order (the load with lower priority is disconnected first). For relay output ...
... If the power output of the PV-plant decreases, or if another load - not connected to the WATTrouter device is switched on, the switched (active) outputs are disconnected - again according to preset priorities but in reverse order (the load with lower priority is disconnected first). For relay output ...
More basic electricity
... Prepare the “voltage vector”, then highlight a range the same size as the vector and enter =MMULT(range1,range2) where range1 is the inverse matrix and range2 is the voltage vector. Then Ctrl-Shift-Enter. ...
... Prepare the “voltage vector”, then highlight a range the same size as the vector and enter =MMULT(range1,range2) where range1 is the inverse matrix and range2 is the voltage vector. Then Ctrl-Shift-Enter. ...
LTM4601/LTM4601-1 - 12A DC/DC uModules with PLL, Output Tracking and Margining
... MPGM (Pin A12): Programmable Margining Input. A resistor from this pin to ground sets a current that is equal to 1.18V/R. This current multiplied by 10kΩ will equal a value in millivolts that is a percentage of the 0.6V reference voltage. See the Applications Information section. To parallel LTM4601 ...
... MPGM (Pin A12): Programmable Margining Input. A resistor from this pin to ground sets a current that is equal to 1.18V/R. This current multiplied by 10kΩ will equal a value in millivolts that is a percentage of the 0.6V reference voltage. See the Applications Information section. To parallel LTM4601 ...
MX Series AC and DC Power Source User Manual
... Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application a ...
... Only qualified personnel who deal with attendant hazards in power supplies, are allowed to perform installation and servicing. Ensure that the AC power line ground is connected properly to the Power Rack input connector or chassis. Similarly, other power ground lines including those to application a ...
Electrical Machine-l (D.C) Laboratory Manual
... two ends are attached to two spring balances S1 and S2.The tensions provided by the spring balances S1 and S2 are T1 and T2. The tension of the rope can be adjusted with the help of swivels. The force acting tangentially on the pulley is equal to the difference between the readings of the two spring ...
... two ends are attached to two spring balances S1 and S2.The tensions provided by the spring balances S1 and S2 are T1 and T2. The tension of the rope can be adjusted with the help of swivels. The force acting tangentially on the pulley is equal to the difference between the readings of the two spring ...
SERIES-PARALLEL DC CIRCUITS
... (For this part you must have supplies with isolated ground connections. If not available, do not complete this part.) (a) Construct the network of Fig. 3.7, taking special note of the fact that the positive side of E2 is connected to ground potential. Using the measured resistor values, calculate th ...
... (For this part you must have supplies with isolated ground connections. If not available, do not complete this part.) (a) Construct the network of Fig. 3.7, taking special note of the fact that the positive side of E2 is connected to ground potential. Using the measured resistor values, calculate th ...