• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

PRG-702: TYRISTOR POWER REGULATOR, SINGLE PHASE
PRG-702: TYRISTOR POWER REGULATOR, SINGLE PHASE

... PRG-702: TYRISTOR POWER REGULATOR, SINGLE PHASE INTRODUCTION Theta’s PRG 702 POWER REGULATORS are suitable for controlling power of load from 1KW to 10KW. The load can be resistive like heaters, or inductive like transformers. The input connection is from 230 VAC supply. It includes various followin ...
Stochastic error: Its behaviour is random from measurement
Stochastic error: Its behaviour is random from measurement

Electricity Rev. Pamphlet
Electricity Rev. Pamphlet

Units, Symbols and Style Guide for Power Electronics Documents
Units, Symbols and Style Guide for Power Electronics Documents

... Throughout this guide, square brackets [ ] will be used for examples of the topic. Separation of quantity and unit --- In the expression for a quantity, leave a space between the numerical value and the unit symbol. [ 1 V, not 1V ] Abbreviations and acronyms --- Technical abbreviations and acronyms ...
ENT161LAB5 - Portal UniMAP
ENT161LAB5 - Portal UniMAP

... The maximum power transfer theorem states that when the load resistance is equal to the source's internal resistance, maximum power will be developed in the load. Since most low voltage DC power supplies have a very low internal resistance (10 ohms or less) great difficulty would result in trying to ...
Problem
Problem

... P.P.11.4 The value of the power absorbed by the 40-V source should be –60W and the value of the power absorbed by the j20-V source should be –40W. ...
TruePower Trio - MA
TruePower Trio - MA

... The new generation of power supplies has arrived with Antec’s TruePower Trio series. The three +12V rails allow you to distribute your power more evenly, which will result in a more stable system. Available in three models: 430 Watt, 550 Watt and a 650 Watt that gives you serious power for even the ...
Dettagli
Dettagli

... • For monitoring of 1 and 3 phase power supply network 230 V AC. • Besides voltage and current you can get value of actual active and reactive power in all phases and this information can be used for automation of connected object. For example for monitoring 1/4 hour maximum. • For permanent moni ...
Presentation - ABCs of Power Conditioning (06
Presentation - ABCs of Power Conditioning (06

... • Complete loss of power for seconds to hours in duration • Usually the result of a power company failure although may have internal facility causes, too. ...
Rail Road FinalApproved NoLogo 13-11
Rail Road FinalApproved NoLogo 13-11

V = IR
V = IR

V = IR
V = IR

... Voltage to Current ratio • We can now state that the ratio V/I for a resistor remains approximately constant for different currents. • Voltage and current are directly proportional ...
review_00
review_00

... connected to a 200-ohm load. It takes 1ms for the wave to travel from the generator to the load. Initially the generator is turned off (zero volts). At time t=0, it is turned on to 10 V. (a) Draw the bounce diagram for the voltage (b) Plot the voltage at the load as a function of time for the first ...
L5: Maximum Power Transfer Theorem background
L5: Maximum Power Transfer Theorem background

... L5: MAXIM UM POWER TRANSFER T HEOREM  BACKGROUND In some circumstances, it is interested to determine the maximum power that can be delivered to a load in a circuit. From this point of view, the circuit consists in a load connected to a dipole, from which the load gets the power. A dipole is a netw ...
Deltaweld® Series
Deltaweld® Series

File - power electronics technology
File - power electronics technology

- Krest Technology
- Krest Technology

TRUECONTROL 2.0 550W
TRUECONTROL 2.0 550W

... and +12V outputs. Get all the power you need when you need it most, and adjust it to your system’s needs. • Dedicated Fan Only power connectors allow TrueControl 2.0 to control the speed of case fans, reducing total system noise. • ATX12V v2.01 compliance allows TrueControl 2.0 to consume up to 25% ...
Exercise Fundamental electrical measurements
Exercise Fundamental electrical measurements

thiet ke web
thiet ke web

... decent introduction if it is new to you. When it comes to writing formulas and units, we have followed the international standards specified in ISO 31 and IEC 27 (or else we have indicated where it is common practice to deviate from the standard). ...
There are inherent problems in single-supply op
There are inherent problems in single-supply op

Sigma Delta A/D converters
Sigma Delta A/D converters

Alternating Currents
Alternating Currents

... or running motors. DC is essential for chemical processes such as electrolysis.  Low voltage DC is used in electronic devices.  AC is much more easily distributed than DC. ...
STK4050V - Linkwitz Lab
STK4050V - Linkwitz Lab

< 1 ... 305 306 307 308 309 310 311 312 313 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report