• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fluke 1760 Three-Phase Power Quality Recorder Topas
Fluke 1760 Three-Phase Power Quality Recorder Topas

Operational Transconductance Amplifier in 350nm CMOS technology
Operational Transconductance Amplifier in 350nm CMOS technology

Extending the Reach of PoE Powered Devices
Extending the Reach of PoE Powered Devices

... The next step was to determine how to provide the PoE functionality. Media converters have been available for many years to convert a copper Ethernet signal to a fiber Ethernet signal, thereby extending the signal reach from 100 meters to 2 kilometers or more. For these traditional devices, the rem ...
Three-Phase Pad-Mounted Transformers for Aclara`s
Three-Phase Pad-Mounted Transformers for Aclara`s

... • OMU Cabling is supplied whenever mounting brackets and cable tray are specified. All of the connectors, and phase cables from the TWCS® Outbound Modulation Unit (OMU) side of the disconnect switch or fuse block to the OMU and from the low side neutral bushing to the OMU will be provided as a stand ...
V4500-MH SERIES Installation Guide
V4500-MH SERIES Installation Guide

... The V4500-MH SERIES is a self-supporting tracking unit that requires only constant power and ground to operate. “H-Series” refers to units that are hard-wired. The unit contains two antennas: one for GPS data and the other for GSM or CDMA communication. You can easily install this unit under the das ...
Manual
Manual

... An active crossover allows a degree of control of the signals and the drive units to a precision not practical or possible in a passive crossover. For example, the response of a passive crossover is affected by the impedance of the drive unit to which it is connected, however the impedance of a driv ...
Document
Document

... A linear transformer couples a load consisting of a 360 Ω resistor in series with a 0.25 H inductor to a sinusoidal voltage source, as shown. The voltage source has an internal impedance of 184+j0 Ω and a maximum voltage of 245.20 V, and it is operating at 800 rad/s. The transformer parameters are R ...
2016 China International Conference on Electricity Distribution
2016 China International Conference on Electricity Distribution

1 - MyCourses
1 - MyCourses

power conditions
power conditions

Using Your Solid State Anodizer
Using Your Solid State Anodizer

... phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Reactive Metals Studio, Inc. and Agilent Technologies assumes ...
Francis SP
Francis SP

Forward and Reflected Powers. What Do They
Forward and Reflected Powers. What Do They

... open curve. This means that for a portion of the cycle, substantial voltage exists across the tube at the same time high current is being drawn through it. This results in the large plate dissipation. In the case of modern FET amplifiers, the output field effect transistors are operated as switches. ...
novel current line sensor based on matched optocouplers for active
novel current line sensor based on matched optocouplers for active

... simulation, and then increases to about 10% at the point where the sensor saturates – here at 8A. The saturation limit depends mainly on the supply voltage VDAQ and the maximum and minimum current levels through the LEDs. Besides the errors shown in these simulation results one should also expect so ...
USER`S GUIDE
USER`S GUIDE

A Single Stage High Power Factor 3 Phase 60v/100a
A Single Stage High Power Factor 3 Phase 60v/100a

... High power factor (HPF) three-phase power supplies have been usually implemented by means of multiple switched stages. The first one is almost always a pre-regulator rectifier stage with high voltage level at its output (-4OOV) [1,2,3,4]. In order to obtain an isolated, regulated and low level outpu ...
EVAL-CN0255-SDPZ Datasheet
EVAL-CN0255-SDPZ Datasheet

... operation over the full industrial temperature range, −40°C to +125°C. ...
experiment 4 - Portal UniMAP
experiment 4 - Portal UniMAP

... secondary voltage with nominal voltage applied to the primary. The current ratio can be evaluated by measuring the short-circuit secondary current with a small ac voltage applied to the primary. The voltage applied to the primary must be low enough to ensure that the nominal current in the primary w ...
Power Measurement
Power Measurement

... current can flow through for develop more torque. (10xUFP). — The large current causes higher voltage drop and power loss in current coil which is introduce an errors. The provision of a compensating is a must to reduce flux created by current coil. — Error caused by pressure coil inductance is prop ...
Sample Curriculum
Sample Curriculum

... panel  inside  suitcase.  When  the  lid  is  removed,   the  case  can  either  stand  or  lie  on  a  table  for  use   by  students.  Color  code  charts  and  component   info  is  included  in  the  lab  manual.   ...
Analog to Floating Point Output
Analog to Floating Point Output

MODIFIED MPPT SCHEME FOR IMPROVING SOLAR CELL
MODIFIED MPPT SCHEME FOR IMPROVING SOLAR CELL

... In Fig 7.b the waveforms of boosted output is being shown. When you take a look at the waveforms the voltage gets boosted by three times the input value and the boosted voltage becomes approximately 203V. This boosted voltage is obtained within a less settling time of around 0.2 sec. The current rem ...
Output Stages Class A, AB, and B Power Stages Laboratory
Output Stages Class A, AB, and B Power Stages Laboratory

to V +
to V +

switched inductor/switched-capacitor combined active
switched inductor/switched-capacitor combined active

< 1 ... 217 218 219 220 221 222 223 224 225 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report