• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Time-domain models for power system stability and unbalance
Time-domain models for power system stability and unbalance

Design Document
Design Document

... The main thing to be taken from the article is how the workers monitored the water levels in the sump and designed a system that would alert them if water levels reached a critical point. This alarm system is an important part in the design of the pump because it ensures that the sump pump will not ...
Aalborg Universitet Damping Inter-area Oscillations using Static Synchronous Series Compensator (SSSC)
Aalborg Universitet Damping Inter-area Oscillations using Static Synchronous Series Compensator (SSSC)

... the DC voltage Vdc constant so that there is no active power input to or output from SSSC, therefore, the result PWM phase angle makes sure that Vc is in quadrature with It and SSSC appears as a reactance. IV. INFLUENCE OF SSSC ON SMALL SIGNAL STABILITY The single-machine infinite bus system in fig. ...
TPA2010D1 数据资料 dataSheet 下载
TPA2010D1 数据资料 dataSheet 下载

Table of Contents 8.0
Table of Contents 8.0

... Onsite DC power system nominal load values are specified in U.S. EPR FSAR Tables 8.3-12 through 8.3-15. {Additional site-specific loads powered from the Class 1E battery source include an additional feeder breaker on the 31/2/3/4BDD bus that provides electrical power to the Essential Service Water E ...
M. Chen, K.K. Afridi and D.J. Perreault, “A Multilevel Energy Buffer and Voltage Modulator for Grid-Interfaced Micro-Inverters,” 2013 IEEE Energy Conversion Congress and Exposition , pp. 3070-3080, September 2013.
M. Chen, K.K. Afridi and D.J. Perreault, “A Multilevel Energy Buffer and Voltage Modulator for Grid-Interfaced Micro-Inverters,” 2013 IEEE Energy Conversion Congress and Exposition , pp. 3070-3080, September 2013.

... steps up the voltage, and the cycloconverter converts the high frequency current into a sinusoidal line-frequency current, which is injected into the grid. Output power can be controlled by a combination of frequency control and phase-shift control. Twice-line-frequency energy buffering in the circu ...
Bridgeless Active Power Factor Correction Using a Current Fed
Bridgeless Active Power Factor Correction Using a Current Fed

... apparent power is called the power factor which is a unit less value between 0 and 1 [1]. The total power delivered to a load is the apparent power and it consists of real and reactive powers. For an electrical system to obtain a power factor of 1, all power absorbed by the load is real power, there ...
Reference Electrode
Reference Electrode

Design, Analysis, and Construction of an Equal Split Wilkinson
Design, Analysis, and Construction of an Equal Split Wilkinson

S260-16-1
S260-16-1

... receptacle. Refer to Figure 19 or 20. When applying SyncCap switches in a three-phase installation, the synchronizing voltage may be provided from each phase independently or from just one reference phase. If the synchronizing voltage is provided independently from each phase, then each SyncCap swit ...
Distance Protection 7SA6
Distance Protection 7SA6

PoE Powered Device for 24 VAC Building Power Applications
PoE Powered Device for 24 VAC Building Power Applications

DOWN LOAD HERE - NOISE LABORATORY CO.,LTD.
DOWN LOAD HERE - NOISE LABORATORY CO.,LTD.

... Since then, in order to dedicate quality advancement in the customers, we have sincerely adopted any requests about the noise testers and provided ESD simulators, Impulse noise simulators, Lightning surge simulators, Simulators for automotive applications, the integrated systems as well as the testi ...
Lecture 4: Transformers
Lecture 4: Transformers

... Analysis of circuits containing ideal transformers A simple method to analyze a circuit containing an ideal transformer is by replacing the portion of the circuit on one side of the transformer by an equivalent circuit with the same terminal characteristics. Next, we exclude the transformer from th ...
50 MHz to 9 GHz 65 dB TruPwr Detector ADL5902
50 MHz to 9 GHz 65 dB TruPwr Detector ADL5902

... from 50 MHz to 9 GHz and can accept inputs from −62 dBm to at least +3 dBm with large crest factors, such as GSM, CDMA, W-CDMA, TD-SCDMA, WiMAX, and LTE modulated signals. The ADL5902 can determine the true power of a high frequency signal having a complex low frequency modulation envelope or can be ...
generator selection contents
generator selection contents

Lab Manual Power Electronics (EE460)
Lab Manual Power Electronics (EE460)

... The total harmonic distortion of a waveform is the ratio of the sum of all the harmonic components except the fundamental over the fundamental component. Using a Fourier series, any periodic waveform can be represented by a series of sinusoids. The fundamental component of the series is the predomin ...
EPM 6000 Power Metering System
EPM 6000 Power Metering System

... • In a system of N conductors, N-1 meter elements will measure the power or energy taken provided that all the potential coils have a common tie to the conductor in which there is no current coil. • Three-phase power measurement is accomplished by measuring the three individual phases and adding the ...
ADL5902 - Analog Devices
ADL5902 - Analog Devices

GIC Quick Start Guide
GIC Quick Start Guide

... can be modeled in PowerWorld Simulator, with their impacts directly included in the power flow  equations.   The document assumes a basic familiarly with PowerWorld Simulator including the power  flow, one‐lines and case information displays.  PowerWorld on‐line training, including videos and slides ...
3PHACBLDCHVPSUG, 3-Phase AC/BLDC High Voltage Power
3PHACBLDCHVPSUG, 3-Phase AC/BLDC High Voltage Power

Aviation Electricity and Electronics—Power Generation and
Aviation Electricity and Electronics—Power Generation and

gei50261 - GE Grid Solutions
gei50261 - GE Grid Solutions

SUBELEMENT G5 ELECTRICAL PRINCIPLES
SUBELEMENT G5 ELECTRICAL PRINCIPLES

RF5616 3.0V TO 5.0V, 5GHz LINEAR POWER AMPLIFIER Features
RF5616 3.0V TO 5.0V, 5GHz LINEAR POWER AMPLIFIER Features

... First, second, and third stage bias voltage combined on the die to one external voltage. This Pin requires regulated supply for best performance. Supply voltage for the PA. Internally decoupled with approximately 100pF. Power detector voltage is proportional to RF output power. May need external dec ...
< 1 ... 13 14 15 16 17 18 19 20 21 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report